An SS7 outage alarm is received in Netcool with the affected DPC. The Tekelec STP is accessed to verify the alarm using the REPT-STAT-RTE command. The M6 tool is used to locate the circuit ID on the affected linkset. This circuit ID is then used to create a ticket in Remedy to resolve the network event.
An SS7 outage alarm is received in Netcool with the affected DPC. The Tekelec STP is accessed to verify the alarm using the REPT-STAT-RTE command. The M6 tool is used to locate the circuit ID on the affected linkset. This circuit ID is then used to create a ticket in Remedy to resolve the network event.
An SS7 outage alarm is received in Netcool with the affected DPC. The Tekelec STP is accessed to verify the alarm using the REPT-STAT-RTE command. The M6 tool is used to locate the circuit ID on the affected linkset. This circuit ID is then used to create a ticket in Remedy to resolve the network event.
Alarm Description/Presentation • When a ss7 Toll Isolation incident occurs, Netcool will present Tier 1 with a DPC Critical Alarm. The alarm will be laid out as follows: SS7 OUTAGE: DPC XXX-XXX-XXX is prohibited LSN=YYYYYYYYY {ZZZZZZZ} • DPC XXX-XXX-XXX represents the Destination Point Code for the end office with a toll isolation • LSN= YYYYYYYYY represents the Linkset Name assigned to this Destination Point Code • {ZZZZZZZ} represents the LOC and PORT number assigned to the link in the STP Tekelec Alarm Verification • Open a GHEM session and connect to the STP using the CLLI • Once a connection is made to the Tekelec STP, access a command prompt. Press CTRL + A and Return on the keyboard. • At the prompt, enter REPT-STAT-RTE:DPC=000-000-000 {RETURN} This DPC number is included in the Netcool alarm Locating the Circuit ID • Access the M6 Information Utility. • Select Equipment located in the search by the drop-down menu under Search Options. Locating the Circuit ID • Click the Goto Equipment Report button Locating the Circuit ID • Enter the alarm HOST CLLI (STP CLLI) in the Network Location field and click the Get CLLI List button. Locating the Circuit ID • Select All Racks from the Net Loc drop-down menu and click the Get Equipment List button. Locating the Circuit ID • Select the Link set Name (LSN) the circuit resides on from the drop- down list. Locating the Circuit ID • Expand the LKST-NAME by double-clicking the Plus sign (+) and then double-clicking the DS0 entry to reveal the circuit ID. Locating the Circuit ID • Select the Circuit ID and do a Copy (CTRL + C) to copy. Creating a Ticket on a Circuit ID • Open the Remedy Ticketing System • Select the Create a New OP Ticket button to create a new ticket for the CCSC. Creating a Ticket on a Circuit ID • Select the Circuit Ticket and click Open Circuit Search to reveal the Circuit ID to Search field. Creating a Ticket on a Circuit ID • Select the Circuit ID to Search field, Paste (CTRL + V) it in the Circuit ID and click Execute Search. Double-click on the search results. • This will attach the CLR/DLR to the ticket and fill in many necessary fields automatically Creating a Ticket on a Circuit ID • In the Products Affected field, select TDM Voice | TDM Voice from the drop-down menu. Creating a Ticket on a Circuit ID • In the Networks Affected field, select SS7/AIN from the drop-down menu. Creating a Ticket on a Circuit ID • From the NOC Trouble Type field, select OUTAGE from the drop-down menu. Creating a Ticket on a Circuit ID • From the Origin field, select Netcool form the drop-down menu. Creating a Ticket on a Circuit ID • The Tier 1 Specialist will need to include any relevant information needed to resolve the network event and click Submit.