CONTROL CONFIGURATION OF
COOLER COOLER/HEATER
HEATER
Control Control Manipulated Control action Control Control Manipulated Control action
objective variable variable taken objective variable variable taken
To ensure the Temperature of Flow rate of When T > set To ensure the Temperature of Flow rate of When T > set
stream pass stream, T cooling water, point, valve stream pass stream, T cooling water, Fs point, valve
through is Fw opening through is opening
cooled enough increase. heated up decrease.
When T < set enough When T < set
point, valve point, valve
opening opening
decrease. increase.
Setpoint Temperature (℃) Type of valve Setpoint Temperature (℃) Type of valve
H-204 105 Diaphragm valve
H-201 230 Diaphragm valve
H-205 120 Diaphragm valve
H-207 55 Diaphragm valve H-202 230 Diaphragm valve
H-304 27 Diaphragm valve
H-205 120 Diaphragm valve
H-306 27 Diaphragm valve
control configuration of steam explosion extraction
column (t-101)
Type of Control Control Manipulated Control Type of
Controller Objective Variable Variable Action valve
Temperature To maintain Column Inlet steam When T>SP, Diaphragm
controller the temperature flow rate valve opening valve
temperature increase.
of the When T<SP,
column valve opening
(T=200oC) decrease.
pH To maintain pH in the Flowrate of When pH<SP, Diaphragm
controller the pH in the column NaOH valve opening valve
column decrease.
(pH=11 to When pH>SP,
11.5) valve opening
increase.
Pressure To maintain the pressure Outlet pressure of stream 22 Pressure transmitter will Diaphragm
inside the reactor at 15 bar send signal to control valve
valve when the pressure is
higher or lower than the
set point
pH To maintain the pH of the Inlet stream 19 containing pH transmitter will send Diaphragm
reactor in acidic condition sulphuric acid signal to control valve valve
when the pH turns alkaline
Flow To maintain the flow of Inlet stream of cooling water Flow transmitter will send Diaphragm
cooling water into the jacket signal to control valve to valve
of the reactor control the flow of cooling
water when the
temperature of reactor is
no longer at set point
Control configuration of phase separator (S-202)
P-303
CONTROL CONFIGURATION OF HYDROGEN
PURIFIER (S-302)
Control
objective
Control
variable
Manipulated
variable
Control action
taken
Type of valve
To control the Pressure in the Outlet flow rate of Pressure in hydrogen Globe valve
pressure in the hydrogen pure hydrogen purifier is detected and
hydrogen purifier purifier stream then a signal will be
sent to the pressure
at desired
controller. The
pressure measured pressure is
compared to the set
point. If the measured
pressure in the
hydrogen purifier is
different from the set
point, a signal will be
sent and outlet flow rate
of pure hydrogen
stream is regulated.
To control the Feed flow rate Feed flow rate to Flow rate detector will Diaphragm
feed flow rate to to the the hydrogen read the feed flow rate valve
the hydrogen hydrogen purifier of hydrogen purifier. The
signal will be sent to the
purifier at desired purifier
flow controller. If there is
flow rate. any deviation from the
set point, then flow
controller will send
signal to the final
element which valve to
regulate the flow rate by
adjusting the valve
opening.
CONTROL CONFIGURATION OF
COMPRESSOR (P-302)
Control Control Manipulated Control Type of
objective variable variable action taken valve
To ensure Pressure at Flow rate of Pressure Diaphragm
the desired outlet of product out transmitter valve
pressure at compressor of detects the
the outlet of compressor pressure
compressor deviation in
is reached compressor
and send
signal to
pressure
controller.
Pressure is
controlled by
regulating
the valve
opening at
outlet
stream.
CONTROL CONFIGURATION OF
EVAPORATOR (S-304)
Control objective Control
variable
Manipulated
variable
Control action taken Type of valve
To control the flow Flow rate of Flow rate of inlet The flow rate of the team is Diaphragm valve
detected, a signal is sent to the
rate of steam inlet steam steam flow controller. The measured
required to flow rate is then compared to
vaporize 80% water the set point. If there is any
from the complex deviations from the set point, a
signal will be sent to the final
solution element
which is control valve of
steam and the steam flow rate
is regulated
To control the Pressure in the Outlet flow rate of Pressure in evaporator is Diaphragm valve
detected and then a signal will
pressure in the evaporator vaporized water be sent to the pressure
evaporator at controller. The measured
desired pressure pressure is compared to the
set point. If the measured
pressure in the evaporator is
different from the set point, a
signal will be sent and outlet
flow rate of vaporized is
regulated.
To control the feed Feed flow rate Feed flow rate to the Flow rate detector will read the Diaphragm valve
feed flow rate of evaporator.
flow rate to the to the evaporator The signal will be sent to the
evaporator at evaporator flow controller. If there is any
desired flow rate. deviation from the set point,
then flow controller will send
signal to the final element
which valve to regulate the
flow rate by adjusting the valve
opening.
LAWS and regulations
EQA 1974 act 127 OSHA 1994 OSHA 1994 Factory and
(CIMAH 1996) Machinery 1967
Likelihood
Severity
Risk
Unit process Work activity Hazard Effect Existing risk control measures Additional measures
Likelihood
Severity
Risk
Unit process Work activity Hazard Effect Existing risk control measures Additional measures
Likelihood
Severity
Risk
Unit process Work activity Hazard Effect Existing risk control measures Additional measures
Catalyst poisoning Less effective in reaction Less pure product Periodically change the catalyst inside the 4 1 4 • Regular check-up and inspection
reactor
HAZARD ANALYSIS
Chemical hazard identification
Chemical Acidity Alkalinity Explosiveness Flammability Toxicity Corrosiveness
Sodium hydroxide No Yes Yes (Heat release No Yes Yes
resulting in fire or
explosion risk)