You are on page 1of 19

Optris CT3M: induction application

 Induction of battery clamps

CT3ML CF
Optris CT 3M applications

 Through plastic welding

 Production of rear lights

Quelle: Leist.
Optris applications: slag vessel

 Slag Vessel

 Truck brings slag to cooling place

 Danger for driver if isolation of


Vessel is damaged !!
Optris applications: slag vessel

 PI with cooling jacket and front protection


window
Optris applications: slag vessel

 PI connect checks for hot spots

 Alarm signal if temp. is too high


Applications of Optris CT laser 1M/2M

Measurements of secondary metal processing, metal


oxides and ceramic materials

Abbildung: Thoma

temperature ranges from 250°C to 1800°C , measuring


spots up from 0,5 mm , response times up from 1ms
IR temperature measurements on metals

Secondary metal processes – tubes and pipes


 Tube Tempering
250-1000°C
CTlaser 2M
 Preheating
CTlaser 2M
 „Folding“
and welding
1500°C
CTlaser 1M

Quelle: Stahl-Zentrum
Applications of Optris CTlaser 1M / 2M

 Temperature
measurement at
forging press

 CTlaser2MH

Quelle: stahl-Zentrum
Applications of Optris CTlaser 1M / 2M

 Temperature measurement of
shrinking
inductive hardening or welding

 CTlaser 2MH or CT 2MH


Applications of Optris CTlaser 1M / 2M

 Steel casting

 CTlaser1M as
replacement for
Heraeus Electro-Nite

Quelle: stahl-Zentrum
IR temperature measurements on metals

Steel mill – Coke Oven


 CTlaser 1M
 1260°C
 Cooling Jacke
Push out
IR temperature measurements on metals

Steel mill – Coke Oven – push out

 CTlaser 1M
 Cooling
Jacket
IR temperature measurements on metals

Steel mill – Sintering


 CTlaser 1M
 1300°C
 Cooling Jacket

Quelle: voestalpine
IR temperature measurements on metals

Steel mill – Blast furnace - Tapping/ Iron /Torpedo Car / Slag


 CTlaser 1M
 1480°C
 Cooling Jacket

Quelle: voestalpine
IR temperature measurements on metals

Steel mill – Steel converter - Oxy / or Electric - C < 2%


 CTlaser 1M
 1650°C
 Cooling Jacket

Quelle: voestalpine , Stahl-Zentrum


IR temperature measurements on metals

Steel mill – Continuous Casting


 CTlaser 1M
 1600°C
 Cooling Jacket

Quelle: Stahl-Zentrum
IR temperature measurements on metals

Steel mill – Rolling


 CTlaser 1M Hot metal detector
 1150°C
 Cooling Jacket

Quelle: Stahl-Zentrum
IR temperature measurements on metals

Secondary metal processes - Forging

 Slabs 1180°C
 CTlaser 1M / 2M
(Peak hold)
 Cooling Jacket

Forging crankshafts
Forging axles etc.

Quelle: Stahl-Zentrum
IR temperature measurements on metals

Secondary metal processes – Wire drawing

 Slabs 1100°C

 CTlaser 1M/2M
 Wire moves,
(PEAK HOLD)

Quelle: Stahl-Zentrum