Professional Documents
Culture Documents
Public Service Escalator: Suzhou Jiangnan Express Elevator Co,.Ltd
Public Service Escalator: Suzhou Jiangnan Express Elevator Co,.Ltd
KX ZY LM P XZ K X ZS K X ZF ZFS KX ZW KS ZW SA -S ,STP S KS ZF LM P SZ K Q LZ
KS ZS
C AB LE(40*0.75m m ^2)
C AB LE(13*0.75m m ^2)
JM BOX
F LO AT
KXW B ZX CA BLE (13*0.75m m ^2)
CABLE(13*0.75mm^2)
CABLE(13*0.75mm^2)
CABLE(13*0.75mm^2)
ZK BOX
K SW
BZXF
BR
LMPX
KXFT
PS
LMPS
KSFT
SA B O IN V
S A BF
JJY
P FC D
KS Y F K S YS
KX YS
K X YY LM P XY K XY F S A -X ,STPX YF S KX YW KS YW LM PS Y K Q LY DD L D DK
M P(LO W E R_S U B) LE D
M P(UP P ER_SUB )
안전 스위치 배치도
M ain C ollocation
U R
5*10 mm2 Cable H01
V S 2*4 mm2 Cable HA1
User Power HA
W T HM HA1
0 0
Heat Stick (Upper Part)
G G 2*1.5 mm2 Cable HAN
HAN
X30
Note: Take HB and HC calbe out of the heat box before transportation,
put them with the tag in the middle and lower parts of escalator;
HE and HF cable should be rolled in the upper part with the tag
D 08 2*0.75m m ^2
JJY
D 09 5*0.75m m ^2
SA-S,S TPS
D 10 2*0.75m m ^2
LM PS
D 11 2*0.75m m ^2 D 23 4*0.75m m ^2
NR S KSFT
D 12 2*0.75m m ^2 D 24 4*0.75m m ^2
SAB O KS W
D 13 2*0.75m m ^2 D 25 4*0.75m m ^2
SABF KQ LZ
D 14 3*0.75m m ^2 D 26 4*0.75m m ^2
PS KQLY
D 15 2*0.75m m ^2 D 27 4*0.75m m ^2
K SZW D D L¡ ¢D DK
D 16 2*0.75m m ^2 D 28 2*0.75m m ^2
K SYW LPSZS
D 17 3*0.75m m ^2 D 29 2*0.75m m ^2
M O D E(U PPER ) LPSY S
D 18 3*0.75m m ^2 D 31 2*0.75m m ^2
SYS POW ER 1
D 19 4*0.75m m ^2 D 32 2*0.75m m ^2
KSZS POW ER 2
D 20 4*0.75m m ^2 D 33 4*0.75m m ^2
KSYS LIG HT(U PPER )
D 21 4*0.75m m ^2 D 56 13*0.75m m ^2
K SZF
M P (U PPER _SU B)
D 22 4*0.75m m ^2
KSYF D 70 2*0.75m m ^2
M P (U PPER _M AIN )
상부 제어반 박스 결선
Cable C ollocation(upper)
M P(LO W ER _M AIN )
D04 40*0.75m m ^2
D 57 13*0.75m m ^2
ZK X JM X M P(LOW ER _SU B)
D 71 2*0.75m m ^2
D55 13*0.75m m ^2
하부 인스펙션 박스 결선
C able Collocation(lower)
D
¡â
5 6
5 6
JXW 3 4
L1 L 2 L3 P FC D
U SER ZK G FCI 1 2 (Power Factor C om p ensation Device)
3 4
PO W E R OCR
T
U 1 2 Y
R 1 2 L1 L1 U U U 21 U 22
1 2 1 2 1 2 1 2
S 3 4 L2 L2 V V V21 MT V22
3 4 3 4 3 4 3~ 3 4
T 5 6 L3 L3 W W W 21 W 22
5 6 5 6 5 6 5 6
0
N N'
G
G 3~
JBZ JBZ1
U 32
Braker
1 2 1 2
JBZ JBZ1 U32 L +
032 BZX DZ T-H
N -
2~
3 4 3 4
O32
JJY DZT-HF
U41
N -
2~
BZX F
U32 L +
5 9
MJ
2~
8 12 041
Y-Δ 기동 회로도
M ain C ircuit (Y-¡ â)
D
¡â
5 6
5 6
JXW 3 4
L1 L2 L3
3 4
USER ZK GFCI 1 2
POWER U OCR 1 2
T Y
R 1 2 U21 U22
1 2 1 2 1 2 1 2
S 3 4 V21 MT V22
3 4 3 4 3 4 3~ 3 4
T 5 6 W 21 W22
5 6 5 6 5 6 5 6
0
N N'
G INV
ENA RUN
G
U1 R W W2
1 2 1 2
V1 S V V2
3 4 3 4
W1 T U U2
5 6 5 6
Braker
JBZ JBZ1 U32 U32 L +
1 2 1 2 BZX D ZT-H
N -
2~
JBZ JBZ1
032 O32
3 4 3 4
-
DZT-H F
N
2~
BZXF
U32 L +
JJY
U41
5 9
MJ
2~
8 12 041
VVVF 기동 회로도
Main Circuit (VVVF)
FAN
XP
XN
MSTSUBISHI FX2N-80MR
I0(COM ) AQ2
102
STATUS COM1
(upper)
U D
Y1
3 30S A1 A2
101
4 40S Y2
X22 13 14
D1(option board)
Y3
RUN CM (control board +5v)
STATUS COM2
13 14
(Down)
EN(control board)
4
D4(control board)
3 30S
TO INVERTER ( ZENER MSC-3)
UP(control board D1)
4 Y4
DOW N (control board D2)
Y5
INV
X21 D2(option board)
13 14 Y6
7(option board)
TH 8(option board)
11 12
입 . 출력 회로도
Control Circuit (VVVF)
101 OCR JXW JTS STPS KSZW KSYW KSZS KSYS
101 95 96 11 14 1 2 1 2 11 12 11 12 11 12 11 12
102
AC 220V ~ STPX JTX AQ1 KQLY KQ LZ KSW KSFT KSYF KSZF
MSTSUBISHI FX2N-80MR
2 1 2 1 12 11 12 11 12 11 12 11 12 11 12 11
24+
COM KXZW KXYW KXZS KXYS KXZF KXYF KXFT KXW KX ZY KX YY
PS
X0 11 12 11 12 11 12 11 12 11 12 11 12 11 12 11 12 11 12 11 12
U
Y31 D
JM A1 A2 21 22
X3
9 5
SA-S SI Y32 Y
¡â
4 A1 A2 21 22
X4
JM DS US
OFF XI
9 1 12 4 12 4 Y
3 X5 Y33 ¡â
4 A1 A2 21 22
SA-X
4
DS OFF Y34
A1 A2
5 9 3
US DS 1
4
5 9 9 1 A1 A2
3 5
7 CJM U 6
2 Y35 101
13 14
US 1
9 1
3 JDDL DDL
5
24+ 110VL 110VN
7 5 9 1 2
14
JM 13 6
CJM D
14
US 13
2
14
DS 13 Y36 AQ2
13 14
FIRE
1 2
X6
Y37
A1 A2
KC
X7
5 9
입 . 출력 회로도
Control Circuit (Y-¡ â)
I0(COM)
C OM 3 CM CM
PSO (upper)
X10 Y10 UP ¨ç
P SO1 PSO 2
MSTSUBISHI FX2N-80MR
( Provided by user )
X11
P SO1 PSO 2
Y12 BREAK D OW N ¨é
M ODE
(upper) STAND-BY ¨ê
Y13
4 AUTO
X12
3
4 M ANUAL
X13
Voice System (Ann)
M ODE
(Low er) Y16 Y15 Y14 Voice M ode
4 C OM 4 DC 24 -
OFF O FF OFF ---
입 . 출력 회로도
Control Circuit (1)
I0(COM )
U
X16
23 24
MSTSUBISHI FX2N-80MR
D
COM5 DC24 +
23 24
Y
23 24
Auto (M ode)
Y24
¡â
23 24
D own Run (¡ è X)
Y25
JBZ
To M ulti Post
23 24
( Provided by O LG )
JBZ1 Up R UN (¡ è X)
Y26
23 24
RU N
Buzzer (BZ)
23 24 Y27
KQLZ KQ LY
21 22 21 22
X17
PO W ER3
( Lower )
3 4
N RS
1 2
X25
D DK
13 14
X26
SABO
11 12
X27
SABF
11 12
O UT(auto heat)
1
1 2
2 X30
입 . 출력 회로도
Control Circuit (2)
I0(CO M)
KSZS
Fault Display
21 22
X31
Code Description
KSYS
X32
1 Bypass Status
21 22
2 M otor Speed Monitor
KSZF
21 22
X33 3 Left Handrail Speed Monitor
4 Right Handrail Speed Monitor
MSTSUBISHI FX2N-80MR
KSYF
21 22
X34 5 Upper Step M issing M onitor
KSFT
DC24 - 6 Down Step Missing Monitor
21 22
X35
COM 7 DC24 + GS 7 Drive Chain Broken Fault
KSW
G 8 Contact Adhere Fault
21
X36
22
GA 9 Upper Left Com b Fault
Y40
KXZS
X37
10 Upper Right Comb Fault
21 22 GB
Y41
11 Upper Left Handrail Entry Fault
KXYS
21 22
X40 GC 12 Upper Right Handrail Entry Fault
Y42
KXZF
13 Upper Step Anti-Jump Fault
GD
X41
21 22 Y43 14 Upper Step Sag Fault
KXYF GE 15 Down Left Com b Fault
X42
21 22 Y44 16 Down Right Comb Fault
KXFT 17 Down Left Handrail Entry Fault
21 22
X43
18 Down Right Handrail Entry Fault
KXW
X44 19 Down Step Anti-Jump Fault
21 22
에러 코드 표시
Fault Display ( LED )
LIGH TING
ZM (20A)
POW ER
XL JZM XP
1 2
Xa ( T )
5 9
AC220V
3 4 LIG HT
Xb ( 0 ) ( Upper )
LPSYS
LPSYS
LPSZS
LPSZS
LMPX
LMPS
3 4
LIG HT
( Lower )
3 4
XN
BYA
110VL
AC110V
110VN
36L
AC36V 36N
AC 220V
SO CKET
(upper)
3 3
JZM S JZM X
AC 36V AC36V
AC 220V SO C KET 4 SO C KET 4
SO CKET (upper) (down)
(dow n)
입 . 출력 회로도
Lighting Circuit
USER RUN1
POWER
C1 HA1 HAN
1 2 1 2 HA
U
3 4 3 4 HB HB1 HBN
V
5 6 HC HC1 HCN
5 6
W
N1 N2
HM
0
PE PE
HC1 HCN HB1 HBN HA1 HAN
TCC
(E5CN)
HM
9 L N 10
PLC : I0 1 C2
TO PLC 1 2 HD
(MITSUBISHI FX2N-80MR) OUT
2
PLC : X30
3 4 HE
3 A 6 Terminal : Kb HE
TDS (Temperature Detect Stick) ALM2
4 B
7 Terminal : Kc 5 6 HF
ALM1 HF
5 B 8 Terminal : Kd
BK1 BK1
JBZF
3 4
U32 L RD Q L1 Q L2
1 2
~ L N
R1 R2 R DZZ1
R C
O32 N
CC(F) ( In BZX )
8 AQ 2 BZ X(F):L 1
10 BK1 3
BK2 4
11 5
12 6
13 7
입 . 출력 회로도 ( 브레이크 )
DZT-H(F) Brake M agnet
Plug of ZKX
C0 C1 C2 C3 C4 C5
Y16 Y14 STATU S MO DE:CM
8 ZFS:¡ è CJM D:1 1 8 (¨ é/Ann) (¨ ç/Ann) 1 8 BP(lower) XL 1 8 KXYY KXZS 1 8 N RS:1 SA-S :C OM 1 8 ( Upper ) PS:+ 1
Y27 Y15 STATU S M O DE:AU
9 YFS:¡ è CJM D:2 2 9 Buzzer Drive (¨ è/Ann) 2 9 40S(lower) XN 2 9 FLO AT KXYS 2 9 N RS:2 SA-S:UP 2 9 ( Upper ) PS:- 2
10 M(OUpper
DE:MA
Y24
10 XYS:¡ è I0 3 10 (Auto/M ode) DC 48 + 3 10 Power3:4 XP 3 10 KXZF 3 10 SABO :11 SA-S:DN 3 ) PS:¡ è 3
PSO1
SI 4 ( lower ) 4 36VL 4 KXYF 4 STPS:1 4 KSZW :11 4
Y25 PSO2
11 S A-X:C OM XI 5 11 (Down Run) ( lower ) 5 11 36VN 5 11 KXFT 5 11 SABO :12 STPS:2 5 11 SYS:+ KSZW :12 5
Y26 MODE:AU
12 AQ1 CJM D:7 6 12 (Up Run) D C48 - 6 12 ( Lower )
110VL 6 12 KXW 6 12 SABF:11 LMPS:L 6 12 SYS:- KSYW :11 6
M O DE:MA
13 AQ2 24+ 7 13 D C24 - DC 24 + 7 13 ( Lower )
110VN 7 13 KXZY 7 13 SABF:12 LM PS:N 7 13 SYS:¡ è KSYW :12 7
연결 플러그 ( 제어반 )
Plug of M ain Controller
Plug of Inspection Box
H0 H1 H2 H3 H4
Y16 Y14 S TATUS STATUS
8 ZFS:¡ è CJMD:1 1 8 (¨ é/Ann) (¨ ç/Ann) 1 8 BP(lower) XL 1 8 KXYY KXZS 1 8 CM(lower)
SA-X:COM 1
Y27 Y15 S TATUS STATUS
9 YFS:¡ è CJMD:2 2 9 Buzzer Drive (¨ è/Ann) 2 9 40S(lower) XN 2 9 FLOAT KXYS 2 9 BP(lower) SA-X:UP 2
Y24 STATUS
10 XYS:¡ è I0 3 10 (Auto/M ode) D C48 + 3 10 Power3:4 XP 3 10 KXZF 3 10 40S(lower) SA-X:DN 3
PSO1
SI 4 ( low er ) 4 36VL 4 KXYF 4 STPX:1 4
Y25 PSO2
11 SA-X:COM XI 5 11 (D own Run) ( low er ) 5 11 36VN 5 11 KXFT 5 11 YFS:+ STPX:2 5
Y26
12 AQ1 CJMD:7 6 12 (Up Run) D C48 - 6 12 MODE:AU
( Lower ) 110VL 6 12 KXW 6 12 YFS:- LMPX:L 6
MO DE:MA
13 AQ2 24+ 7 13 D C24 - D C24 + 7 13 ( Lower ) 110VN 7 13 KXZY 7 13 YFS:¡ è LMPX:N 7
H5 H6 H7 H8 H9 H10
Y16 Y14
8 MO DE:CM
( Lower ) ZFS:+ 1 8 KXZS:21 KXZS:11 1 8 KXYF:21 KXYF:11 1 8 KXZY:21 KXZY:11 1 8 (¨ é/Ann) (¨ ç/Ann) 1 8 Power3:3 STM :1 1
Y27 Y15
9 MO DE:AU
( Lower ) ZFS:- 2 9 KXZS:22 KXZS:12 2 9 KXYF:22 KXYF:12 2 9 KXZY:22 KXZY:12 2 9 Buzzer Drive (¨ è/Ann) 2 9 Power3:4 STM :2 2
MODE:MA Y24
10 ( Lower ) ZFS:¡ è 3 10 KXYS:21 KXYS:11 3 10 KXFT:21 KXFT:11 3 10 KXYY:21 KXYY:11 3 10 (Auto/M ode) DC48 + 3 10 3
PSO1
KXZW :11 4 4 4 4 ( lower ) 4 4
Y26 PSO2
11 XYS:+ KXZW :12 5 11 KXYS:22 KXYS:12 5 11 KXFT:22 KXFT:12 5 11 KXYY:22 KXYY:12 5 11 (Up Run) ( lower ) 5 11 5
Y25 LIGHT:3
12 XYS:- KXYW :11 6 12 KXZF:21 KXZF:11 6 12 KXW:21 KXW :11 6 12 FL0AT:21 FL0AT:11 6 12 (STOP) DC48 - 6 12 ( Lower ) 6
LIGHT:4
13 XYS:¡ è KXYW :12 7 13 KXZF:22 KXZF:12 7 13 KXW:22 KXW :12 7 13 FL0AT:22 FL0AT:12 7 13 DC24 - DC24 + 7 13 ( Lower ) 7
연결 플러그 ( 인스펙션 박스 )
Plug of Inspection Box
Left Panel Right Panel
S TO P
POWER
On O ff
D IR EC TIO N
Up D ow n
H E ATIN G
O ff
A uto M anu
M O DE
Note:
A uto M anu
1¡ ¢PO W ER Key: M anual Reset ( ASW 2K11 )
2¡ ¢HEAT Key: M anual Reset ( ASW 3K20 )
LIG H T
STA T US
3¡ ¢LIGHT Key: M anual Reset ( ASW 2K11 )
A uto M anu 30S
4¡ ¢STO P Button: Auto Reset ( ABW 111R )
BP 40S
5¡ ¢DIRECTIO N Key: Auto Reset ( ASW 33K20 )
6¡ ¢M ODE Key: M anual Reset ( ASW 3K20 )
7¡ ¢STATUS Key: M anual Reset ( ASW 3K20 )
운전반
O peration Panel
( MP 1 C on nector )
M ulti Post
( upper ) ( M P1 C on nector )
M ulti P ost
( Low er )
( provided by O LG ) ( P rovided by OLG ) ( provided by OLG ) ( P rovided by O LG )
M P1-13 M P1-13
GS
GA
GB
Safety Error Code D isplay
GC
provided by SJEEC GD
GE
멀티 포스트
M ulti Post
10s 10s
Speed(m/m) ( No person ) ( No person )
40S/30S
<20min 20min
12S
0S
Time(s)
Scan sensors
30S/40S 30S/40S
12S
D2(Y6) 0S 12S 0S
INVETOR D1 D2 D3
param eter (COM 2) (Y6) (Y7)
Hz Speed(m/s)
OFF OFF OFF 0 V0 : 0S Note:1¡ ¢ Speed 30S or 40S selected by status key
P11 ON OFF ON 18 V1 : 12S 2¡ ¢ 12S mean 12metre/minute
3¡ ¢ 30S mean 30metre/minute
P12 ON ON OFF 46 V2 : 30S
4¡ ¢ 40S mean 40metre/minute
P13 ON ON ON 60 V3 : 40S
Common M ushroom
Button Button Inspection Plug
3 4 3 4 1 2
Mushroom Button 3 5
4 UP
Up Run Button
Up Run Button
Inspection Panel
Note£º
Cable Length: Escalator 20m
Conveyor 30m
리모콘 (MSB)
Inspection Panel
PFCD
(Power Factor Com pensation Device)
L1 U
L2 V
L3 W
KM
capacitance
QF
KM
10 9 8 7 6 5 4 3 2 1
IT1
IT2
US1
역률 보상 장치
Power Factor Com pensation Device
INVERTER (ZENER MSC-3)
FAN
ZKX ( In BR box)
(Main Control Box) XP
K04 (2*0.75mm2)
XN
Control Board RL1
Option Board
+5V D1 D2 D3 D4 EN D1 D2 D3 TH+ TH-
C10 1 2 3 4 5 6 13 14 1 2 3 7 8
TH
8 1 ( In BR box)
INV:CM 11 12
9 2
INV:FWD
10 3
INV:REV
4
INV:D2
11 5
INV:D1 INV:D3
12 6
INV:13
13 7
INV:14
BR
K02 (13*0.75mm2)
L1 L2 L3 M1 M2 M3
R1 R2 R3
B1 B2
U1
K03 (2*10mm2)
V1
W1
U2
본 사각 박스 부분은 OLG 에서
V2
Local 공급 .
W2 나머지 파트는 SJEEC 에서
공급 .
K01 (7*10mm2)
인버터 접속 회로도
Inverter Interface