You are on page 1of 57

EAME Service Training

PLE6xx Installation
Ref REHS8850

Olivier Clisse - October 2015

1
EAME Service Training

PLE Install Content List from REHS8850 –


2

check this
1. Identify if PL-ready/installed or not on your product
2. Mount A5N2 following ‘A5N2 rules’
3. Mount Radio(s) following ‘Radio rules’
4. Install PRO/Elite harness without radio connection
5. Connect 8 main wires to the equipment
6. Key ON and Winflash via Ethernet cable
7. Upload Config file (if any, get or create it)
8. ET Checks and ET Configuration
9. Connect Radio(s)
10. Launch Service Dashboard Communication-check

Caterpillar: Confidential Yellow


EAME Service Training

1. Identify if Equipment is PL-ready/installed 3

Caterpillar: Confidential Yellow


EAME Service Training

Caterpillar: Confidential Yellow


EAME Service Training

2. Mount A5N2 following ‘A5N2 rules’

• Shock mounted
• Horizontally mounted
• In harness reach
• Within Temperature and Moisture range
• Don’t forget ground strap
• 1m max CAN-length to main trunk if shielded (PS)
• 3m max CAN-length to main trunk if not shielded (EM)

Caterpillar: Confidential Yellow


EAME Service Training

3. Mount Radio(s) following ‘Radio rules’


• External Antenna mounted horizontally
• Internal Antenna (if PL641i) => mount radio horizontally
• No metallic cover
• 0.5m away from other antenna (min)
• Within Temperature & Moisture range
• Total Ethernet length < 100m
• Total coax antenna extension < 4.5m
• Coaxial radius > 50mm

• DO NOT CONNECT RADIO YET*

Caterpillar: Confidential Yellow


EAME Service Training

4. Install PRO/Elite harness 7

without radio connection*

5. Connect 8 main wires to the equipment


Caterpillar typical wires-names & numbers

•Batt + =125
Elite
•Ground = 200
•Key Switch = 308
•R-term = 403
•CDL + = 945,893 Pro
•CDL - = 944,892
•CAN + = Y795, F711
•CAN - = Y794, F712
•Can Shield
Caterpillar: Confidential Yellow
EAME Service Training

Useful Components for splices

P/N 199-9785: 1 socket to 2 pins

P/N 207-3814: 1 pin to 2 sockets

P/N 115-8109: orange splice

Caterpillar: Confidential Yellow


EAME Service Training

10

12-24V Relay for KeySwitch

• 12V Relay: 115-1615 Relay As


• 24V Relay: 3E-5239 Relay As

Caterpillar: Confidential Yellow


EAME Service Training

11

Reminder: System Block Diagram

Caterpillar: Confidential Yellow


EAME Service Training

12

PL harness up to Ethernet Port #1: primary radio

Caterpillar: Confidential Yellow


EAME Service Training

PL harness up to Ethernet Port #2: 13

secondary radio (option)

Caterpillar: Confidential Yellow


EAME Service Training

14

PL harness up to Radio Disable Switch (PS option)

Caterpillar: Confidential Yellow


EAME Service Training

15

PL harness up to Ethernet Port #3: Modbus

Caterpillar: Confidential Yellow


EAME Service Training

16

PL harness up to Ethernet Port #4: Service Port

425-6889

Caterpillar: Confidential Yellow


EAME Service Training

PL harness up to the rest of the Equipment: 17

CAN & CDL

Caterpillar: Confidential Yellow


EAME Service Training

18

Reminder: PLE Install - REHS8850 –


1. Identify if PL-ready/installed or not on your product
2. Mount A5N2 following ‘A5N2 rules’
3. Mount Radio(s) following ‘Radio rules’
4. Install PRO/Elite harness without radio connection
5. Connect 8 main wires to the equipment
6. Key ON and Winflash via Ethernet cable
7. Upload Config file (if any, get or create it)
8. ET Checks and ET Configuration
9. Connect Radio(s)
10. Launch Service Dashboard Communication-check

Caterpillar: Confidential Yellow


EAME Service Training

19

6. Key ON and Winflash via Ethernet cable*


• Don’t forget to change your ET communication settings:

Typical screen if you forget


=> (E.T. / Utilities / Preferences / Modify ) …

425-6889

Caterpillar: Confidential Yellow


EAME Service Training

20

Flashing PLx6xx Devices *


•Connect service tool 425-6889 or 305-5528
to service port:

Caterpillar: Confidential Yellow


EAME Service Training

*
21

And launch Winflash :

Note: CR = A5N2, YC = PL631, YD = PL641


(or TR = latest A5N2)

Caterpillar: Confidential Yellow


EAME Service Training

22
Flash- & Config-files located in ‘SISweb’ and/or
‘Dealer.cat.com/PL’

Caterpillar: Confidential Yellow


EAME Service Training

7. Upload Config file (if any) * 23

via PLx6xx Webpage


• 3 ways to get to the PLx6xx Webpage
A) Via E.T. / Utilities / Browse Product Network Devices
B) Via Cat ECM Finder (external app doing the same)
C) Manually putting your laptop in PL-range (165.26.78.x, 255.255.254.0)

or

Caterpillar: Confidential Yellow


EAME Service Training

24

ET / Utilities / Browse Product Network Devices

Note: above example for Elite Dual Antenna:


A5N2, PL641 and PL631 each count as one ECM
(all 3 devices show the same IP in this screen.)

2 3
Caterpillar: Confidential Yellow
EAME Service Training

25

Automatic jump to the PLx6xx Webpage: 165.26.78.1

Service
Dashboard

Product
Link

Caterpillar: Confidential Yellow


EAME Service Training

26

Upload all config files (If any) via the “Product Link” Tab

• The configuration file tells your PL-device


what to do with your equipment data.

Caterpillar: Confidential Yellow


EAME Service Training

27

Configuration files for Machines via SISweb

Caterpillar: Confidential Yellow


EAME Service Training

Configuration files for ‘Oil & Gas’: via dealer.cat.com 28

• https://dealer.cat.com/PL/Toolbox
• Link to E&TS Industrial Protocol Reports for PL6 Configuration
Files on Power Net

Caterpillar: Confidential Yellow


EAME Service Training

29

Creating your own ‘customer’ config file via PL-Web

Use example of JAZ00468 in PL-web

REHS9763 now also includes information about “Modbus configuration”

Caterpillar: Confidential Yellow


EAME Service Training

30

Reminder: PLE Install - REHS8850 -


1. Identify if PL-ready/installed or not on your product
2. Mount A5N2 following ‘A5N2 rules’
3. Mount Radio(s) following ‘Radio rules’
4. Install PRO/Elite harness without radio connection
5. Connect 8 main wires to the equipment
6. Key ON and Winflash via Ethernet cable
7. Upload Config file (if any, get or create it)
8. ET Checks and ET Configuration
9. Connect Radio(s)
10. Launch Service Dashboard Communication-check

Caterpillar: Confidential Yellow


EAME Service Training

31

8. ET Checks and ET-Configuration.


• Switch back to Commadapter 2 or 3 (CAN and CDL)
• Check individually for proper CAN and CDL comm.
• Check for R-term input (engine running): CAN or 403 wire
• Finally Set up the ‘Product Id’ in Configuration screen

Caterpillar: Confidential Yellow


EAME Service Training

32
8.a. Check for proper CAN & CDL connections

Unclicked !!!

If A5N2,
verify it shows up
in both CDL and CAN

Caterpillar: Confidential Yellow


EAME Service Training

33

8.b. Check for R-Term input through CAN or 403- wire:

Caterpillar: Confidential Yellow


EAME Service Training

34

8.c. Finally configure the ‘Product Id’ in ET Config screen


either for the A5N2 (Elite) or for the Radio (Pro)

•The Telematics ‘Product ID’ default is “CAT00000” .


•If changed, the PLE601 (Elite) or the PL6x1 (Pro)
will automatically generate a new registration message.
•Along with the new registration message,
the equipment will be subscribed in the User Interface
based of the entered ‘Product ID’.

Caterpillar: Confidential Yellow


EAME Service Training

35

ECM Time Setting & SMU Synchronization

Caterpillar: Confidential Yellow


EAME Service Training

36

Reminder: PLE Install - REHS8850 -


1. Identify if PL-ready/installed or not on your product
2. Mount A5N2 following ‘A5N2 rules’
3. Mount Radio(s) following ‘Radio rules’
4. Install PRO/Elite harness without radio connection
5. Connect 8 main wires to the equipment
6. Key ON and Winflash via Ethernet cable
7. Upload Config file (if any, get or create it)
8. ET Checks and ET Configuration
9. Connect Radio(s)
10.Launch Service Dashboard
Communication-check
Caterpillar: Confidential Yellow
EAME Service Training

9. Connect the Radio(s) 37

10. Launch Service Dashboard


‘Communication-check’
• Connect the PL Radio(s)
• Get back to previously opened PLx6xx Webpage,
• Open “Service Dashboard”

Caterpillar: Confidential Yellow


EAME Service Training

e.g. PL641 Service Dashboard


38

For the technician to check comm.

Caterpillar: Confidential Yellow


Download for DSN support
EAME Service Training

e.g. PLE641 Service Dashboard


39

Radio 1
Radio 2
Modbus

Here is the flash file of the A5N2

Creates html file Creates tgz file

Caterpillar: Confidential Yellow


EAME Service Training

40

PL641 Service Dashboard / General Info

Caterpillar: Confidential Yellow


EAME Service Training

41

PL641 Service Dashboard / Radio Info

S/N Suffixes:
-YC = Sat (Pro)
-YD = Cell (Pro)
-CR or -TR = A5N2 (Elite)

acceptable
from -20 to -99 dBm*

Caterpillar: Confidential Yellow


EAME Service Training

42

PL641 Service Dashboard / GPS info

Caterpillar: Confidential Yellow


EAME Service Training

43

PL641 Service Dashboard / Ethernet

Caterpillar: Confidential Yellow


EAME Service Training

44

Summary of PLE Install - REHS8850


1. Identify if PL-ready/installed or not on your product
2. Mount A5N2 following ‘A5N2 rules’
3. Mount Radio(s) following ‘Radio rules’
4. Install PRO/Elite harness without radio connection
5. Connect 8 main wires to the equipment
6. Key ON and flash via Ethernet cable
7. Upload Config file (if any, get or create it)
8. ET Checks and Configuration
9. Connect Radio(s)
10. Launch Service Dashboard Communication-check

Caterpillar: Confidential Yellow


EAME Service Training

45

Extras

Caterpillar: Confidential Yellow


EAME Service Training

46

Star Network: See Spec Instruct M0068740 !

• Connect the to Port 1 of your Elite harness


• Connect a Category 5e or 6 LAN cable to your local
network
• Configure the A5N2 Settings / Network Config / Port 1
as explained in REHS / “PLE601 Communication With
Local Area Network (LAN)”
• Ref to UENR5823 for additional info
on Network Config &
Firewall Requirements
• Also ref to M0068740,
Elite on Marine Systems & Dual Mode

Caterpillar: Confidential Yellow


EAME Service Training

M0068740: Elite in Network Configuration


47

Caterpillar: Confidential Yellow


EAME Service Training

M0068740: Elite in Network Configuration & Dual Mode 48

Also read

“ECM Exclusion” *
&
“MID Override” **

Caterpillar: Confidential Yellow


EAME Service Training

49

Modbus
• Modbus® is an openly published serial communications
protocol developed by Modbus with widespread use in
industry. This protocol is commonly used over RS-232, RS-
485, and Modbus TCP/IP networks. The RS-232, and RS-
485 version is a master/slave protocol, whereas the
TCP/IP version is a peer-to-peer protocol. The strengths of
this protocol are simplicity and low implementation cost.

• It has become an industry standard method for the transfer


of discrete/analog I/O information and register data
between industrial control and monitoring devices (PLC)

Caterpillar: Confidential Yellow


EAME Service Training

Modbus TCP/IP Ethernet connection 50

1. Connect Ethernet converter 419-5974 Adapter


to the 6-pin connector (port #3) on the Network Manager
2. Connect the Ethernet cable between Port #3 and your laptop
3. ‘Detect Ethernet Devices’ & open up PL-Interface (http://165.26.78.1/)
then click “Industrial Bus” tab.
4. Click the table to edit the listening ports for Modbus TCP.

Caterpillar: Confidential Yellow


EAME Service Training

A5N2 Network Config: Modbus, Port #3. 51

Never configure Port #3 in range of Service-Port #4

Never remove these 2 opportunities


for future Over-The-Air flashing

Good example above

Caterpillar: Confidential Yellow


EAME Service Training

52

Modbus RS 232

• From a web browser window, navigate to the Product Link


web page of he ECM
• Click on the "Modbus Config" tab, and then select "Modbus
RTU Config" from the left-hand menu.

Caterpillar: Confidential Yellow


EAME Service Training

53

Modbus RS 485
• From a web browser window, navigate to the Product Link
web page of he ECM
• Click on the "Modbus Config" tab, and then select "Modbus
RTU Config" from the left-hand menu.

RS-485
Port TxA- TxB+ RxA- RxB+ Shield
1 5 4 18 17 6

Caterpillar: Confidential Yellow


EAME Service Training

54

Dual Antenna Installation (See REHS8850)

• Information now added in REHS


• Look for “Dual-Mode” with search function
• Kits now available for Upgrading Engines- & Machines:
– E.g. 455-5563 to upgrade a PLE631 to dual
– E.g. 455-5564 to upgrade a PLE641 to dual

Caterpillar: Confidential Yellow


EAME Service Training

55

Dual Antenna Installation (See REHS8850)


1. Install the new radio
2. Connect the GPS antenna to your preferred radio
(recommended is to the Sat Radio)
3. Connect the Cell antenna coax (brown) to Cell Radio
4. Connect the Sat antenna coax (white) to Sat Radio
5. Connect the PC to your PLE-webpage / Settings &
6. Select “GPS Configuration” * screen to
7. Configure it to “Cat Radios Sat” or “Cat Radios Cell”
depending where you ve connected the GPS coax on step2

Caterpillar: Confidential Yellow


EAME Service Training

56

Reminder: Modbus: Eth,RS485 or Serial

1 RS485
(4,5,6,17,18)

14 RS232
19 Port1
PL121 type
24 (13,22,23,3
RS232 28 0,31)
Port 2
32 CAN (27,35,
(34, 43) 36
CAN* (2ndary) 42,
40
(33, 40, 41) 50)

+
Main
48 Ethernet Ethernet
Port 3 53 Port 4 (Service)
(48,49,58, (55,56,
RS232 – Port 3
-
58 59,60) (62,63,64)
66
* 57,68,69)

Caterpillar: Confidential Yellow


EAME Service Training

57

PL 6x1 Radio PinOut

What do you think you need to check on your Radio?


Caterpillar: Confidential Yellow
EAME Service Training

58

Radio lights system


(Ref “LED Lights on the Radio”, REHS8850)

• Power
– GPS
• Cell or Sat Comm
- Ethernet Comm ___on Elite- or
- CAN Comm ______on Pro-installations

Caterpillar: Confidential Yellow