BUILDING CORE ANALYSIS MECHANICAL

BUILDING TYPOLOGY: VENTILATION


COMMERCIAL COMPLEX FIRE STAIRCASE TOILET A.H.U.
CORE TYPE:
LIFTS AND
SPLIT CORE
STAIRCASE
•HEIGHT OF BUILDING : 20 MTS
•FLOOR TO FLOOR HEIGHT : 3.5MTS

CONTENTS OF CORE
VERTICAL CIRCULATION
ELEVATOR AND STAIRCASE
SERVICES
ELEMENTS OF SERVICES
• FIRE STAIRCASE
• PLUMBING
• LIFT
• TOILET

ARRANGEMENT PATTERN OF VERTICAL


DISTRIBUTION:
•THE ELEVATORS AND SERVICES TOGETHER.
•DUE TO WHICH THE HORIZONTAL CIRCULATION IS
NOT EASIER.
•HENCEIT NEEDS TO BE REDESIGNED.
•SPLIT CORE CAN BE REDESIGN.

STAIRCASE:
•THEY SHOULD BE CLEARLY VISIBLE AND SHOULD
EASY TO IDENTIFY.
ELEVATORS USE OF RE-DESIGNING :
•WIDTH OF STAIRS : 1.5 M
•SIZE OF ELEVATORS • COST REDUCTION
•LENGTH OF FLIGHT 12 STEPS IN ONE FLIGHT.
NORMAL : 1.75 X1.45 • GOOD HORIZONTAL CIRCULATION
•PITCH OF STAIRS SHOULD NOT EXCEED THAN 40
SERVICE : 1.75 X 2.25 • PROPER DUCTING
•LANDING OF FLIGHT : 1.5 M
• ALL SERVICES WILL BE IN ONE PLACE.
•RISER SHOULD BE 150MM
•TREAD SHOULD BE 300 MM

SHREYASH
ANALYSIS OF SERVICE CORE IN COMMERCIAL COMPLEX .
MECHANICAL
VENTILATION
FIRE STAIRCASE TOILET A.H.U.
LIFTS AND
STAIRCASE
REDESIGN OF CORE
STAIRCASE
• TOTAL 3 STAIRCASES ARE PROVIDED AS
PER DESIGN.
(2 FIRE STAIRCASE AND 1 NORMAL )
•FLIGHT WIDTH OF FIRE STAIRCASE IS 2MTS
•RISER IS 150MM AND TREAD IS 300MM.
•4 HOUR FIRE RESISTANT MATERIAL IS GIVEN
TO THE FIRE STAIRCASE.
•FIRE STAIRCASE ARE NOT ACCESSIBLE TO
THE BASEMENT AS IT ENDS UP TO THE
GROUND FLOOR.
•2 FIRE STAIRCASES ARE PROVIDED
AROUND 30MTS.
`
ELEVATOR
•ELEVATORS ARE PROVIDED AS PER THE
DESIGN REQUIREMENT.
•SERVICE LIFT IS PROVIDED OF 1.7M X
2.25M.

SERVICE / GOODS
LIFT

SHREYASH
RESDESIGN OF SERVICE CORE IN COMMERCIAL COMPLEX .
STRUCTURAL SYSTEM
•STRUCTURE : RCC FRAME STRUCUTRE.
•COLUMN SIZES : IT VARIES AS PER THE
SPAN.
•MASONRY : 230MM THICK BRICKS ARE
PROVIDED.
•ALL THE PASSAGE LIGHTS,LIFTS HAVE
POWER BACKUP.
•EMERGENCY LIGHT BACKUP ARE
PROVIDED IN EVERY SHOP AND OFFICES.
•RAIN WATERE HARVESTING AND
RECYCLE METHODS ARE USED.
•SOLAR LIGHTING SYSTEMS ARE GIVEN
FOR TOILET AND ATRIUMS .
•FIRE STAIRCASES ARE PROVIDED AT
CONVENIENT PLACES. ELEVATION TREATMENT
•LANDSCAPING IS DONE INSIDE THE •CURTAIN WALLS ARE PROVIDED TO THE BUILDING AS ITS GIVES
COMPLEX NEAR TO THE FOOD COURTS. GLAZING AND MODERN ` LOOK.
•SOLAR CONTROL GLASS ARE PROVIDED BECAUSE IT CAN CONTROL THE
HEAT FROM SUN THAT ENTERS THE COMPLEX.
•BUFFER WALLS LOUVERS ARE PROVIDED TO HIDE THE DUCT AND
PIPING OF THE TOILET AND THE OTHER SERVICES.

CURTAIN WALLS
FIXING OF CURTAIN
WALLS

ELEVATION TREATMENT IN SHREYASH


.
COMMERCIAL COMPLEX