Siddipet medical college

CIRCULATION VERTICAL CIRCULATION

1.HORIZONTAL IT IS SIMPLY ALL WALKING AREAS AND MECHANICAL TOOLS INSTALLED IN ALL


FLOORS OF A BUILDING REQUIRED FOR VERTICAL PHYSICAL ACCESS TO SOME
SPACES INCLUDING STAIRCASES, RAMPS, ELEVATORS AND ESCALATORS
2. VERTICAL
STAIRCASE
1.HORIXONTAL CIRCULATION
• THERE ARE 8 STAIRCASES AROUND THE MEDICAL COLLEGE BLOCK

HORIZONTAL CIRCULATION IS HOW PEOPLE MOVE FROM ONE SPACE TO ANOTHER ON A • 4 ARE AROUND THE CORNERS OF THE BLOCK AND REMIANING 4 CONECTS THE
SINGLE FLOOR. NEXT FLOOR FROM THE CENTRE OF THE BLOCK.

HORIZONTAL CIRCULATION MIGHT INCLUDE HALLWAYS, ATRIA, PATHS, CORRIDORS, ENTRIES • TREAD=300MM; RISER=250MM; WIDTH=2000MM
AND EXITS.
• ALL THE STAIRCASE ARE OF TYPE DOG-LEGGED STAIRCASE.
• IN TOTAL THERE ARE 3 ENTRY/EXITS FROM THREE SIDES OF THE MEDICAL COLLEGE.IN
WHICH ON ENTRY ACTS AS SERVICXE ENTRY AND OTHER TWO ACTS AS MAIN ENTRIES RAMPS
FOR THE STUDENTS. • RAMPS ARE PROVIDED OVER THE ENTRY AND EXITS OF THE COLLEGE AND THE
RATIO OF RAMP IS 1:10 I.E., 10%
• 1.8M AND 2M CORRIDORS FOR THE STAFF AREA WHICH DIVIDES THE STAFF ROOMS.
LIFTS
• THERE ARE TWO LIFTS USED FOR VERTICAL CIRCULATION WITH THE CAPACITY
• 3M CORRIDORS FOR CIRCULATION INSDIE THE MAIN BLOCK FROM ONE SPACE TO
OF 6-8 PERSONS PER LIFT
OTHER SPACE. THESE ARE USED TO MOVE FROM DISSECTION HALLS TO STAFF ROOMS
AND TO ADMINISTRATION ETC.
STAIRCASES
• AS THERE SHOULD BE FREE CIRCULAYTION FOR STUDENTS THERE’S A 4.5M CORRIDOR
AROUND THE LECTURE GALLERIES. RAMP

• THERE’S A LOBBY WHICH CONNECTS CENTRAL LIBRARY AND ANOTHER ENTRY OF THE LIFTS
MEDICAL BLOCK

RAMP
CORRIDOR

HORIXONTAL CIRCULATION STAIRCASE LIFTS


INTERNAL WATER SUPPLY
• TOILETS ARE PROVIDED WITH
DIFFERENT DIA OF PIPES FOR
DOMESTIC WATER SUPPLY.
• OVER HEAD TANKS ARE • LABS DO HAVE WASH BASINS AND ARE
PROVIDED SEPERATELY FOR CONNECTED WITH SAME WATER
DOMESTIC PURPOSE(3 SUPPLY PIPES AS SUCH TOILETS AND
TANKS) AND FOR FIRE EACH LAB CONTAINS 40 WASH BASINS.
FIGHTING PURPOSE(2
TANKS) WITH CAPACITY OF
75.000L AND 50,000L
(APPROX) RESPECTIVELY ELECTRIC SERVICES
• THERE’S ELCETRICAL POWER SUPPLY
ROOM IN EVERY FLOOR BESIDE LIFT.
• LECTURE HALLS ARE PROBIDED WITH AIR
DIFFUSERS FOR FRESH AIR.
• THERE ARE CEILING LIGHTS, TUBE
LIGHTS, CEILING FANS, EXHAUST FANS
• THERE IS A MAIN TRANSFORMER TO APPLIANCES IN LECTURE HALLS
CONDUCT EKECTRICITY FOR COLLEGE.

INTERNAL WATER SUPPLY

SEWERAGE SYSTEM
• WASTE FROM TOILETS AND LABORATORY
CHEMICALS ARE COLLECTED THROUGH SOIL
WASTE PIPES OF DIA 110MM AND THESE ALL
SOIL WASTE PIPES ARE CONNECTED TO
GROUND DRAINAGE AT 2 MAIN POINTS.
• SOIL WASTE IS COLLECTED FROM
WASHBASINS AND ARE CONNECTED TO
DRAIN HOSES.
• SOIL WASTE FROM COLLEGE IS COLLECTED
AND DRAINED TO STP[SEWAGE TREATMENT
PLANT] WHICH IS LOCATED AWAY FROM THE
COLLEGE

MEDICAL COLLEGE

SEWAGE TREATMENT PLANT (STP)


FOR MEDICAL COLLEGE AND HOSPITAL
SITE PLAN
SEWERAGE SYSTEM SUMP FOR MEDICAL COLLEGE

TRANSFPORMER YARD FOR MEDICAL


COLLEGE
FIRE SAFETY
• THIS BUILDING IS BUILT UNDER PROPER FIRE SAFETY NORMS
• IT HAS FIRE EXTINGUISHERS AND ALSO FIRE EXIT ROUTES IN
EVERY FLOOR RELATIVELY CLOSE TO EXITS OF THE BLOCK
• IT HAS FIRE AND HEAT DETECTORS ALL ALONG THE PARKING
AND LECTURE HALLS., ALONG WITH THESE LECTURE HALLS
AND PARKING HAS SPEAKERS, HOOTERS FOR AWARENESS.

FIRE HOSE SYSTEM

HEAT DETECTOR

FIRE ALARM

CO2 FIRE
EXTINGUISHER
FIRE ESCAPE ROUTE

ABC- FIRE
EXTINGUISHER

SWOT ANALYSIS
STRENGTHS OPPURTUNITIES

1. WHOLE SITE IS LOCATED NEAR KOMATI CHERUVU, THEREFORE, NO 1.THERE MIGHT BE FUTURE EXPANSION
SCARCITY OF WATER 2.
2. 3.
3. 4.
4.
THREATS
WEAKNESS 1.
2.
1. NO RAIN WATER HARVESTING PIT 3.
2. 4.
3.
4.