New HMI Panels
CP600 range - Some rules for the webinar

 Dial the Genesys phone No: +33 1 72 21 38 53

 Please mute your phone line during presentation.

 Use chat to ask questions or hints for all.

 For better screen view, use icons “Fit to screen” and then
“Maximize” a right corner of sametime meeting
.

 In case you only see a grey screen please inform immediately.

 All documents (presentation, example, an so on …) will be


send to all participants after presentation.
Week 10
2012
• AC500 – application example
Controlling ACS800 via EtherCat
Week 08
2012
• AC500 – Data Types
Handling of arrays and structures
Week 06
2012
• AC500 – CI541-DP & CI542-DP
Profibus DP Slaves
Week 04
2012
• AC500 - Technical Support Tool
PowerHelp handling
Week 03
2012
• CP600 range – Trends, Alarms & Recipes
AC500 & CP600 range - Webinars schedule
Next Subjects
New HMI Panels
CP600 range – Summary
 Working with Trends
 Presentation
 Configuration and programming
 Demonstration

 Working with Alarms:


 Presentation
 Configuration and programming
 Demonstration

 Working with Recipes:


 Presentation
 Configuration and programming
 Demonstration
PB610 Panel Builder
Working with Trends

 Configuring trend buffers


 Sampling conditions: Time, Trigger
 Boundaries
 Mechanism to save space in memory
 Historical trend
 Trend files
 Each buffer has its own file on disk
 Viewing trends
 Extracting data: Dump to USB
 Real time trends
 No data storing

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 5
PB610 Panel Builder
Working with Trends

 Trend limits:
 Number of trend buffers = 30
 Number of curves per trend widget = 5
 Number of curves per page = 10
 Number of samples per each trend buffer = 200 000

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 6
PB610 Panel Builder
Working with Trends (1)

 Configuring a trend buffer


 Trend viewer
 Configuring action for dump
 Open the trend editor
 Add a trend buffer

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 7
PB610 Panel Builder
Working with Trends (2)

 Configure buffer options


 Source: Tag to be sampled
 Size: Size of the buffer in number of samples
 Trigger
 Blank: disabled
 Tagx: allows to sample “on event”
 Low and High Limits (boundaries)
 The sample is stored if
 (current value – previous value) < Low Limit
 (current value – previous value) > High Limit

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 8
PB610 Panel Builder
Boundaries Concept

V2

V3

V1

V0

t t+1 s s+1

V1 – V0 > High V3 – V2 < Low

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 9
PB610 Panel Builder
Working with Trends (3)

 Locate the Trend viewer in gallery


 Drag & Drop it on the page
 Configure the viewer
 Scale X and Y, Grid and Curve

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 10
PB610 Panel Builder
Working with Trends (4)

 History viewers
 Requires refresh!!

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 11
PB610 Panel Builder
Working with Trends (5)

 Configure the action to dump data


 Data is exported in binary format
 CSV Export in preparation
 Requires conversion to CSV

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 12
PB610 Panel Builder
Working with Trends (6)

 External utility to decode the data


 TrendBufferReader.exe
 Batch file
 TrendBufferReader -r TREND\Trend1 csv\Trend1.csv 1
 Format of exported file
 DataType,Value,Timestamp(UTC),SamplingTime(ms),Q
uality

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 13
PB610 Panel Builder
Alarms/Events and Alarm History

 Alarms and Events concept


 Configuring Alarms
 Triggers
 Actions
 Alarm historical list
 Buffers
 Visualization of alarm history
 Dumping Alarms and Events
 Live Tag values in alarm description
 Alarms can be enabled/disable at runtime

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved
PB610 Panel Builder
Trigger Conditions

 Bit mask
 Bit status withing the tag

 Limits
 Triggered is out of “safe” zone

 Deviation
 Percentage deviation of tag value
from set point

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 15
PB610 Panel Builder
Working with Alarms (1)

 Configuring one alarm


 Alarm widget
 Events viewer
 Open Alarm editor from Project tree
 Give a name to the alarm
 Enable the alarm
 Configure Ackowledge
 Set monitored Tag
 Decide where log is stored

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 16
PB610 Panel Builder
Working with Alarms (2)

 Configure Actions to be executed when trigger occurs

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 17
PB610 Panel Builder
Working with Alarms (3)

 Configuring Alarm behavior


 Decide when widget is updated
 Decide when the alarm state change is logged
 Decide when the alarms action is executed

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 18
PB610 Panel Builder
Working with Alarms (4)

 Configure the action to DumpEventArchive


 Data is exported in binary format
 CSV Export in preparation
 Requires conversion to CSV

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 19
PB610 Panel Builder
Working with Alarms (4)

 Configuring the alarm widget


 From widget gallery
 Advanced category
 Widgets for alarm visualization
 Widget for Event buffer visualization

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 20
PB610 Panel Builder
Working with Alarms (5)

 Use of the display Filter


 Runtime options
 Default sorting
 No runtime change

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 21
PB610 Panel Builder
Recipes

 Working with recipes


 Configuring recipes
 Recipe, Element, Set
 Storing recipes data
 Recipe data files
 Extracting data
 Backup and Restore to USB
 Handling recipes
 Menu selection
 Download/Upload

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 22
PB610 Panel Builder
Recipes limits

 Number of recipes = 32
 Number of parameter sets for recipe = 32K
 Number of elements per each recipe = 1000

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 23
PB610 Panel Builder
Working with Recipes (1)

 Configuring one recipe


 Using the standard widget for recipe operation
 Right click on “Recipe” to insert a new element
 Double click on Recipe name to open the recipe editor

 Configure Elements and Sets

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 24
PB610 Panel Builder
Working with Recipes (2)

 Locate the recipe widget in gallery


 Advanced\Recipe Source
 Drag & Drop the widget on page
 Configure the widget
 Assign the recipe from “Recipe Name”

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 25
PB610 Panel Builder
Working with Recipes (3)

 Use action to save and restore recipes


 Recipe data is saved in CSV format

© 2010 Sitek S.p.A, An Exor International Inc. Partner Company


All rights reserved 26
HMI Panels CP600
CP600 Documents

 Link to CP600 Web page


 Link to CP600 range Brochure (pdf format)
 Link to CP600 – PB610 Panel Builder 600 manual (pdf format)

 You can find also an E-learning course named F854e, available within
the ABB University ( training Partner tool ) where you can find CP600
range description, + arguments, benefits, applications, and Competitor
comparisons.
Link to Training Partner tool:

You might also like