You are on page 1of 20

MCRNC ALARMS

ETHERNET LINK FAILURE

NOKIA
IMPORTANT TO KNOW – ARCHITECTURE AND
CONFIGURATION
BCN – Box Controller Node
SFP0 SFP2 SFP4 SFP6

Factory usage
4x RJ-45

2xUSB
Alarm and sync 1xRJ-45
7x10GE 2x10GE 10x1GE
1x1GE

Debugging interfaces,
Tracing

Hardware
interfaces BCN UTRAN UTRAN interfaces 2x1GE (not used by mcRNC) maintenance
interconnect interfaces DCN

SFP1 SFP3 SFP5

NOKIA
IMPORTANT TO KNOW – ARCHITECTURE AND
CONFIGURATION
BCN – Box Controller Node
• Each BCN contains two (2) Internal Switches

• Main Switch – Which has SFP0, SFP1, SFP2, SFP3, SFP4, SFP5, SFP6 & Trace
Port plus others linked internally

• External Switch – Which has SFP11, SFP12…..SFP21 & SFP22 + Others linked
internally

NOKIA
IMPORTANT TO KNOW – ARCHITECTURE AND
CONFIGURATION
BCN – Box Controller Node
Standard Working Configurations for mcRNC are;

• S1 or Step-1 – This is made up of two (2) BCNs

• S3 or Step-3 – This is made up of four (4) BCNs

• S7 or Step-7 – This is made up of eight (8) BCNs

NOKIA
IMPORTANT TO KNOW – ARCHITECTURE AND
CONFIGURATION
BCN – Box Controller Node
Standard Working Configurations for mcRNC are;

S1-B2 S3-B2 S7-B2

NOKIA
IMPORTANT TO KNOW – ARCHITECTURE AND
CONFIGURATION
BCN – Box Controller Node
Based on the configuration, the interconnection interface are utilized
BCN Interconnect

Factory usage
4x RJ-45

2xUSB
Alarm and sync 1xRJ-45
7x10GE 2x10GE 10x1GE
1x1GE

interfaces,
Tracing

Hardware
BCN UTRAN UTRAN interfaces 2x1GE (not used by mcRNC) maintenance
interconnect interfaces DCN

NOKIA
IMPORTANT TO KNOW –
ARCHITECTURE AND CONFIGURATION
BCN – Box Controller Node
Based on the configuration,
the interconnection interface
are utilized

NOKIA
IMPORTANT TO KNOW –
ARCHITECTURE AND CONFIGURATION
BCN – Box Controller Node
Based on the configuration,
the interconnection interface
are utilized

NOKIA
IMPORTANT TO KNOW –
ARCHITECTURE AND CONFIGURATION
BCN – Box Controller Node
Based on the configuration,
the interconnection interface
are utilized

NOKIA
IMPORTANT TO KNOW –
ARCHITECTURE AND CONFIGURATION
BCN – Box Controller Node

By default, all BCNs are delivered with S7-B configuration, where all the Interconnect SFPs are enabled.

When ports are enabled but are NOT utilized, it raises ETHERNET LINK FAILURE
alarm.

It is the responsibility of the commissioner of the BCN to know the RNC configuration and configure the
ports correctly

NOKIA
INVESTIGATE AND CORRECT
ETHERNET LINK FAILURE IF
CAUSED BY WRONG PORT
CONFIGURATION

NOKIA
INVESTIGATE AND CORRECT
ETHERNET LINK FAILURE ALARM
CHECK ALARM

NOKIA
INVESTIGATE AND CORRECT
ETHERNET LINK FAILURE ALARM
CHECK SPECIFIC ALARM DETAIL

NOKIA
INVESTIGATE AND CORRECT
ETHERNET LINK FAILURE ALARM
CHECK RNC CONFIGURATION

NOKIA
INVESTIGATE AND CORRECT
ETHERNET LINK FAILURE ALARM
CHECK SWITCH PORT STATUS

NOKIA
INVESTIGATE AND CORRECT
ETHERNET LINK FAILURE ALARM
CORRECT PORT CONFIGURATION
The RNC has scripts inside it to correct the configuration to the required status permanently

The scripts can be found at:


/opt/nsn/SS_QNTools/script/

The scripts are listed below and must be executed with the root authority;

zs1_sfp_disable_bcnb.scli

zs3_sfp_disable_bcnb.scli
zs7_sfp_disable_bcnb.scli

NOKIA
INVESTIGATE AND CORRECT
ETHERNET LINK FAILURE ALARM
CORRECT PORT CONFIGURATION

NOKIA
INVESTIGATE AND CORRECT
ETHERNET LINK FAILURE ALARM
CHECK SWITCH PORTS AGAIN

NOKIA
INVESTIGATE AND CORRECT
ETHERNET LINK FAILURE ALARM
CHECK ALARMS AGAIN

NOKIA
INVESTIGATE AND CORRECT
ETHERNET LINK FAILURE ALARM

Thank You

NOKIA

You might also like