SMT. KAMALA AND SRI VENKAPPA M.

AGADI COLLEGE OF
ENGINEERING AND TECHNOLOGY LAXMESHWAR-582116
2021-2022
DEPARTMENT OF MECHANICAL ENGINEERING

PROJECT ON

DESIGN AND FABRICATION OF


SAVONIUS WIND TURBINE
Under the Guidance of
Dr.Suresh Bujari

PROJECT ASSOCIATES
Basavaraj.R.Mishrikoti [2KA19ME401]
Kiran.M.Konanatambigi [2KA19ME404]
Mabusab.R.Bentur [2KA19ME407]
Sateesh.C.Shirabadagi [2KA19ME414]
CONTENTS

Schematic Diagram
Design Calculation
Materials
BLOCK DIAGRAM

1000

800
DESIGN CALCULATION

Diameter of blades (d) =150 mm


Gap (e) = 0.15*d
= 0.15*150
= 22.5mm
Rotor diameter (D) = d+d-e
=150+150-22.5
=277.5mm
Rotor height (h) = 1000mm
End plate diameter ( Do) = 1.1*D
= 305.25mm
Thickness of blades & end plate ( t ) = 3mm
Assume TSR = 6
Velocity of air = 5m/s
Density of air = 1.2 kg/m3

Velocity of blade = TSR*Vair


= 6*5
= 30

Swept area (As) = π×D×h


= 3.142*0.2775*1
= 0.871 m3
Power (P) = 1/2 ρAv3
= 1/2*1.2*0.871*5^3
= 65.32 W
Co-efficient of power (CP) = 0.36*h*D*v3
= 0.36*1*0.2275*5^3
= 12.48 W
MATERIALS

Wind turbine blades :

Material of blade : alluminium


Thickness : 3mm
Diameter of blade : 150 mm
Height of blade : 800mm
Bearing

A ball bearing is a rolling element that uses balls to

maintain the bearing

NSK 6313 Ball bearing

It is used between the rotor and the frame to hold the


rotor vertically
Alternator

Alternator used to generate the electricity to from the


mechanical motion of shaft of turbine
Specification of the Alternator :
Input: 1250 rpm
Output: 12-13 V
Battery

Flat plate batteries that do not emit any fumes or


gases on a continuous basis

These batteries are used as a part of UPS and


inverter

SMF batteries are used for solar power storage


applications
STATUS OF PROJECT

40

60

60% work is completed


40% remaining PROJRCT COMPLITION
DATE : 06/06/2022