Emissions

Exhaust Port Locations

• IMPORTANT – Do not sample from the exhaust


collector.
• There are no set positions to take samples. These are
only guidelines. The minimum EPA longitudinal
sample port locations are…
• Two stack diameters downstream from transitions or
bends.
• One stack diameter upstream from the stack exit plane.
• In some situations, the only way to locate the sample
port is accessibility and common sense.
Cal gas kits
The standard Solar kit will consist of 4 calibration gases – CO, NO,
NO2 & N2.

  Stainless Steel Flow Controlled


Regulator with Overflow Vent
Print out data input

• The local date and time should be already


set.
• Test site name
• PD number
• Engine serial number
• Model
• FSR name
Print out sample
Analyzer data

3 programmable lines

T60-7301S
Data Location name

Date and time

Test data

Analyzer data

Programmable footer