Customer Shell
Site Dunlin
PD 47911
Eng S/N 1054M
Model M100-15000S
Point No. Date Time NGP NPT T1 Pamb Rh T2 Pcd Fuel Flow % Pilot On/Off T5
SBVT5SPD_X2
SBVT5SPD_X3
SBVT5SPD_X4
SBVT5SPD_X5
SBVT5SPD_X6
SBVT5SPD_X7
Point No. Nox ppm CO ppm O2 % NO ppm Tana (F) cNOx ppm cCo ppm Fuel O2ref % NO2 ppm CO2 % Tf (F)
SBVT5SPD_X2
SBVT5SPD_X3
SBVT5SPD_X4
SBVT5SPD_X5
SBVT5SPD_X6
SBVT5SPD_X7
Generator set results
Customer Shell
Site Dunlin
PD 47911
Eng S/N 1054M
Model M100-15000S
Point No. Date Time Load T1 Pamb Rh T2 Pcd Fuel Flow %Pilot on/off T5
SBVT5SPD_X2
SBVT5SPD_X3
SBVT5SPD_X4
SBVT5SPD_X5
SBVT5SPD_X6
SBVT5SPD_X7
Point No. Nox ppm CO ppm O2 % NO ppm Tana (F) cNOx ppm cCo ppm Fuel O2ref % NO2 ppm CO2 % Tf (F)
SBVT5SPD_X2
SBVT5SPD_X3
SBVT5SPD_X4
SBVT5SPD_X5
SBVT5SPD_X6
SBVT5SPD_X7
Mars KVAL Data
BHP
T12000S 0463M
MD
SYMBOL KVAL DESCRIPTION
PILTONSP F13;394 LOW EMISSION MODE ON
PILT1OFFSP F13;447 LOW EMISSION MODE OFF
PILT3OFFSP F13;448 LOW EMISSION MODE OFF
BVCL_T5SP T5 SETPOINT FOR CO
BVCL_TPZSP TPZ SETPOINT FOR CO
SIVCNT5SPLO F13;368 SIV OPEN
SIVCNT5SPHI F13;369 SIV CLOSE
T5REFHIGPG F13;272 T5 TOPPING GAS
T5REFHIGPL F13;273 T5 TOPPING LIQ
Analyser Calibration Data
APPENDIX Q
EMISSIONS ANALYZER INTEGRITY DATA DATA TABLES FOR: LEAK CHECK
ZERO CHECKS
CAL VERIFICATION
CROSS-SENSITIVITY CHECKS
Data Table Q1
LEAK CHECK & ZERO CHECKS
Pre-Test Inter-Test Inter-Test Inter-Test Post-Test
[s ample N2] [sam ple N2] [sample N2] [s ample N2] [sample N2]
Check Target Target Target Target Target
Type Sensor Concent Reading Concent Reading Concent Reading Concent Reading Concent Reading
Leak [1] O2 0 %vol 0 %vol 0 %vol 0 %vol 0 %vol
Zero [2] CO 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm
Zero [2] NO 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm
Zero [2] NO2 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm
1 The sample system is considered air-tight when an O2 reading of 0.0% to 0.2% vol is obtained when sampling N2.
2 Sensor zeros are considered acceptable when CO, NO, & NO2 readings from 0 to +/- 2 ppm are obtained when sam pling N2.
Data Table Q2
CALIBRATION VERIFICATIONS
Cal Gas Pre-Test Inter-Test Inter-Test Inter-Test Post-Test
Bottle [s ample cal gases] [sam ple cal gas es] [sample cal gases] [s ample cal gases] [sample cal gases]
Concent Stable Stable Stable Stable Stable
Sensor [ppm ] Reading Diff [3] Reading Diff [3] Reading Diff [3] Reading Diff [3] Reading Diff [3]
CO
NO
NO2
3 Difference = (Stable Reading - Cal Gas Bottle Concentration)
Data Table Q3
CROSS-SENSITIVITY CHECKS
Sensor Reading
Cal Gas Sampled CO [ppm ] NO [ppm] NO2 [ppm]
CO
NO
NO2