Introduction to

Raised Floor System

AEC Interiors is one of the leading names in Raised Floors in Pakistan. We provide
Raised Flooring services in Karachi, Lahore, Quetta, and Peshawar. Over the years,
we have completed many key projects throughout Pakistan. In this article, we have
provided comprehensive information regarding Raised Floors.
Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.
1
Ph.0345-3383788
Introduction of Raised Floor System?

Raised floor systems may also be called False Flooring Systems or Access
Flooring Systems. This elevated structural floor has a void above a concrete
floor to allow electrical, mechanical, and data cables to pass through.

It is the most effective way to create a void for cable management in the
computer room (cable tray system). There is easy access to every point of
the floor with the Raised Floor system.

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


2
Ph.0345-3383788
Application of Raised Floor System?

There are many applications for False Floors


• Control Room
• IT Centers
• Data Centers
• High-rise buildings
• Office Area
To accommodate services, false flooring is installed at varying heights,
ranging from 200mm to more than 1200mm.

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


3
Ph.0345-3383788
Raised Floor Structure

Raised Floor Tiles


These tiles are typically made of particle board or Cement filled steel
tile. 
These tiles may be covered with various flooring finishes, such as HPL,
Vinyl, and carpet tiles, to suit the application need.

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


4
Ph.0345-3383788
Support pedestal
Pedestals are adjustable floor height supports for raised flooring rigid
systems. This pedestal is designed to support removable floor panels. The
number of cables and other services determines the height of the pedestal.

There is a minimum height requirement of 200 millimeters and a standard


height requirement of 300 millimeters. The control room and electrical room
require pedestals that are 600mm tall.

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


5
Ph.0345-3383788
Stringers
Stringers are an integral part of the frame. It is used to connect pedestals. It
is the stringers that support the raised flooring panel. As a result, the
structure is braced, and the load is evenly distributed across the pedestals.

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


6
Ph.0345-3383788
Raised Floor Types
Raised floors can be classified into different categories based on their
function and need.

• Cementitious Raised Floor


• Wooden Raised Floor
• Calcium Sulfate Raised Floor

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


7
Ph.0345-3383788
Cementitious Raised Floor
Steel panels with a cementitious core are used for the construction of the panels. In
general, the panel measures 600mm by 600mm and is 32mm thick. An HPL or vinyl
covering would be applied to its top surface. The panel frame has been coated with
epoxy, and the base has a perimeter shape. 
As far as loading capacity, durability, and fire rating are concerned, this tile is ideal.
Application Area
• Electrical Room
• Control Center
• IT Center
• Server Room Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.
8
Ph.0345-3383788
Wooden Raised Floor
This type of false Floor is made of particle board (chipboard) with a top
surface made of HPL or vinyl. The bottom surface is covered with a GI sheet
for fire rating. The standard tile size is 600 x 600, with a thickness of 38 mm.
You should consider this false floor type if antistatic and lightweight are your
main concerns.
Application Area
Server Room
Office Building
Telecommunication Room

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


9
Ph.0345-3383788
Calcium Sulfate Raised Floor
The panel looks like a false floor panel made of wood. It is usually 600x600
and 38 mm thick. It consists of calcium sulfate with a top surface of HPL or
vinyl and a bottom surface of GI sheeting.
Its excellent load capacity, antistatic properties, and electrical resistance
make it an ideal false floor type.
It is, however, more expensive than the other false floor variations. The
disadvantage of this type of panel is that it is heavy and difficult to move an
additional load on the building structure.
Application Area  
• Control Room
•  Server Room
• Electrical Room
Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.
• IT Room Ph.0345-3383788
10
Perforated Raised Floor Tiles
An air conditioning system with underfloor air distribution typically supplies
cooling air from below and exhausts it into the room when computer
equipment is used. 
The conditioned air must be directed under the computer system using
perforated Raised Floor tiles.

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


11
Ph.0345-3383788
Raised Floor Top Finishes
HPL (High-Pressure Laminated)
The tile's surface is coated with high-pressure laminate (HPL) to provide an
antistatic raised flooring surface. There are several advantages to this type of
surface cover, including scratch resistance, dust resistance, and stain
resistance. The standard thickness is 1.2 mm. and the standard electrical
resistance is 1×108–1×1011 ohms.

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


12
Ph.0345-3383788
Vinyl Cover
A vinyl surface cover is ideal if your main objective is to create a more
capable anti-static raised floor and ensure electrical resistance. Its standard
thickness is 2 mm, and its electrical resistance ranges from 2.5 x 104–1 x 106
ohms. Consequently, this surface covering is ideal for sensitive equipment
areas, such as telecommunications and information technology rooms.
However, this type of cover is not scratch-resistant, heat-resistant, stain-
resistant, or fire-rated.
It is an ideal surface covering for sensitive equipment, such as
telecommunications and information technology rooms.

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


13
Ph.0345-3383788
Bare Finish Raised Floor Tiles
A bare-finish tile will be the most suitable option when using a panel in high-
rise buildings for LGS (Light Gauge System) purposes. Later, this tile’s top
surface is covered with a porcelain or carpet tile. A bare finish tile is cost-
effective that leaves the option for custom finishing according to the theme
and need of the interior.
The Bare finish false floor tile is often used in high-rise buildings, offices,
hallways, lobbies, museums, etc.

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


14
Ph.0345-3383788
False Floor Loading Criteria
According to the PSA MOB PF2 PS and BS/EN12825 UK benchmarks,
different raised floors can bear various weights.
False Floor for Control Room, Server Room, and Data Center
It is generally recommended that PSA heavy grade be used in computer and
control rooms, including data centers. It should deliver 12 kN/m2 UDL and a
4.5 kN point load, with a 3x safety factor applied.

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


15
Ph.0345-3383788
False Floor for Office Building
The weight-bearing standard for false flooring in office buildings is PSA
medium, which carries a uniformly distributed load of 8 kN/m2 and a point
load of 3.0 kN. The loadings are subject to an additional 3x safety factor.
Raised Floor Tile Puller
Raised floor pullers, tile lifters, or suction lifters are tools with a suction
rubber cup. It is easy to remove tiles with a tile puller vacuum suction.

Office# 1010, Park Avenue, Main Sharah-e-Faisal Karachi.


16
Ph.0345-3383788
Raised Floor Price in Pakistan
It is an imported product and is not manufactured in Pakistan. Raised
Floor Price frequently changes due to its dependence upon the dollar
exchange rate.
If you intend to use Raised Flooring in your project, we offer a free
consultation to help you select the right product within your budget.