Terminal Objectives
UNCLASSIFIED
3
Enabling Objectives
• IDENTIFY the equipment, function, and employment considerations
for portable Fire Fighting Equipment.
• IDENTIFY the equipment, function, and employment considerations
for portable Dewatering Equipment.
• IDENTIFY the equipment, function, and employment considerations
for Pipe Patching Equipment.
• IDENTIFY the equipment, function, and employment considerations
for Shoring Equipment.
• IDENTIFY the equipment, function, and employment considerations
for Emergency Access Equipment.
• DISCUSS the safety considerations of all equipment.
UNCLASSIFIED
4
Fire Fighting Equipment
UNCLASSIFIED
5
Purple-K-Power (PKP)
Dry Chemical Extinguisher
• Class BRAVO fires
• Extinguishes the fire by breaking up
the combustion chain reaction
• No cooling capability
• Sizes: 18 / 27 pounds
• Ranges: 19 / 21 feet
• Discharge Times: 10 / 11 seconds
• Compound will foul electronic
components
UNCLASSIFIED
6
Carbon Dioxide (CO2)
Extinguisher
• Class CHARLIE fires
• Extinguishes the fire by displacing
oxygen
• Size: 15 pounds
• Range: 4 to 6 feet
• Discharge Time: ~35 to 40
seconds
• Located within 30ft of equipment
with high potentials for a class
“C” Fire
• Keep grounded to deck to avoid
shock from static electricity
UNCLASSIFIED
7
Aqueous Film-Forming Foam
(AFFF) Extinguisher
• Class BRAVO fires
• Extinguishes the fire by creating
a vapor barrier and cooling
• Size: 28lbs (2.5gal of premixed
AFFF producing 16gal of foam)
• Range: 10ft and decreasing
• Discharge Time: 45 to 65 sec
UNCLASSIFIED
8
AFF Inline Eductor
• Used in conjunction with the
95gpm Vari-nozzle
• 5gal AFFF bottle or 55gal drum
• Providing a mixing ratio of
6% AFFF to 94% H2O
UNCLASSIFIED
9
Naval Firefighter’s
Thermal Imager (NFTI)
• Used to locate the seat of a fire in
smoke filled and dark spaces
• Operated by the Attack Team Leader
• 2 modes of operation: PAN-while
moving, CHOP-while fighting the fire
• Can “wash out” in an environment that
is too hot for too long
UNCLASSIFIED
10
Dewatering Equipment
UNCLASSIFIED
11
P-100 Portable Emergency Pump
• Diesel engine driven centrifugal pump
• Provides 100gpm at 83psi
• 20ft suction lift; max 39ft when used with a portable educator
• Be mindful of exhaust if operating inside the ship
UNCLASSIFIED
12
Electric Submersible Pump (ESP)
UNCLASSIFIED
13
Perijet Eductor
• Jet-type pump, no moving parts
• Often used with an ESP or P-100 pump
• Can be used with fluids with small
particulate matter or that are more viscous
UNCLASSIFIED
14
S-Type Eductor
• Jet-type pump, no moving parts
• Often used with an ESP or P-100 pump
• Has a Foot Valve with a strainer to prevent
flooding and clogging
UNCLASSIFIED
15
Pipe Patching Equipment
UNCLASSIFIED
16
Soft Patch
UNCLASSIFIED
17
Jubilee Patch
UNCLASSIFIED
18
Emergency Water-Activated
Repair Patch (EWARP)
• Used for systems with 150 psi or
less and does not exceed 300
degrees
• Cannot be used on fuel or potable
water systems (can contaminate
the system)
• 2 Sizes: 3in x 9ft, 4in x 15ft
• Fully hardened in 30 minutes
UNCLASSIFIED
19
Various Patches
• Box Patch: effective for holes with
jagged edges
• Hinged Plate Patch: designed for
use over relatively small holes
• Folding T-Patch: used for
unevenly shaped holes
• Hook Bolts: used to anchor a
patch
UNCLASSIFIED
20
Shoring Equipment
UNCLASSIFIED
21
Shoring Materials
• Shore: a portable beam. Douglas Fir or Yellow
Pine preferred (straight grained, cured woods)
– Carried in lengths of 16ft to 18ft and should
never be painted
– The length of a shore should never be more
than 30 times its minimum thickness
• a shore of 4in x 4in or 4in x 6in should not
be any longer than 10ft (4in x 30 = 120in)
• Wedge: a block, triangular on the sides and
rectangular on the end
– Made of Fir or Yellow Pine (soft woods)
– Approximately the same width as the shores
it’s being used with and about 6 times as long
as it is thick (if a shore is 4in x 4in, the wedge
should be about 4in wide, 2in thick, 12in long)
UNCLASSIFIED
22
Shoring Materials
UNCLASSIFIED
23
Steel Shoring Materials
• Model 3-5 is adjustable from 3ft to 5ft and can
support a vertical load of 12,000lbs to 20,000lbs
• Model 6-11 is adjustable from 6ft to 11ft and can
support a vertical load of 6,000lbs to 20,000lbs
• Advantages: Can also be welded into place,
fireproof, easier to store, less materials need,
greater variety of use, prefabricated
UNCLASSIFIED
24
Types of Shoring
• I Type: Consists of a single beam between an anchor point and a
strong back (simplest and strongest type)
• K Type: Used if a single anchor point is not readily available
– Constructed using the Measuring Batten Method
or the Framing Square Method
UNCLASSIFIED
25
Emergency Access Equipment
UNCLASSIFIED
26
Plasma Exothermic
Cutting Unit (PECU)
• Used for cutting into a
deck to vent a
compartment due to
extreme temperature
from a fire that is
preventing normal
entry
• Uses expendable rods
which combine
oxygen and fuel to
create a cutting torch
• Must wear PPE while
operating (gloves and
goggles)
UNCLASSIFIED
27
Portable Hydraulic Access and
Rescue System (PHARS)
• Utilized in emergency access, personnel rescue, or fire-fighting
operations involving spreading, cutting, pulling, and piercing light
plate or sheet metal (may also be called jaws of life)
• Powered by small, external diesel engine (JP-5 or F-76)
• Must wear PPE while operating (gloves and goggles)
UNCLASSIFIED
28
Portable Electric Access and
Rescue System (Power Hawk)
UNCLASSIFIED
29
Questions?
UNCLASSIFIED