Opsis International Sales Meeting 2005

FASTLOOP SYSTEM
OR..

The “Alternative” path


Opsis International Sales Meeting 2005

DOAS -The perfect installation site


Nice conditions

Nice long paths


Close

Nice
height
No vibrations
Very easy access
Opsis International Sales Meeting 2005

Bypass monitoring The


NOT be mixed “Fastloop”
with traditional Concept
Extractive
monitoring We do NOT
systems! change the gas
content. We are
• No pumps
Emitter just moving the
Receiver
• No drying or measuring point!
filtering
• No change of the
gas
conditions!
THE FAST LOOP CELL
Design Example
Inlet
(after fan)

120 mm 2" Insulated Pipe


(or tube)

Option: Insulated Measure


Calibration Loop (Opsis part) AC
Fan Zero Air

see drw.
   
D302792

Outlet
(before fan)

Option:
External fan Drainage
Example With Fixed Tubing and External Fan
7
SO2,NOX,CO,CO2,Hg(0),Hg(tot) monitoring with
FAST LOOP DOAS TECHNOLOGY

FAST LOOP WITHOUT CELL


HEATED PROBE
HEATED SAMPLE LINE
ID FAN 3 WAY VALVE
HEATED CONVERTER
EJECTOR PUMP

STACK

EM HEATED CELL RE

USING FAST LOOP : AR


•VERY SHORT HEATED SAMPLE LINE CAN BE USED
•FAST TRANSPORT TIME (FOR THE SAMPLE)
Fast Loop Cell here, make brackets on the
wall to support Fast Loop cell
Return pipe going into duct
prior to blower
Approx
routing of
fast loop tube
FAST LOOP CELL FROM THE EMITTER SIDE

12
FAST LOOP CELL FROM THE RECEIVER END

13
COMPLETE FAST LOOP CELL

14
FLUE GAS FROM 15 MTR HEIGHT FROM STACK

15
FAST LOOP CELL TEMPERATURE MEASUREMENT PROBLEM SORTED
OUT AFTER PROPER INSERTION OF THERMOCOUPLE

16
System400HG Vertical
System400Hg Horizontal
System400Hg Dual Duct (1)

MX
System400Hg Dual Duct (2)

Sample switch