General Objectives
A good ventilation takes out around the half of the heat of grinding
2 3 8 False air
Enough Air/mat. interference?
air? False air
material 7
1 L/D too high outlet
-250 mm
WG
Dust
47000 m³/h Collector
Ventilation at ~ 34400
100°C
Nm³/h
Material Diameter = 3.6 m -150mm = 1.3 m/s empty mill
WG
and also: 0.5 Nm³/kg of
C1 C2 cement
37000 m³/h
20°C
30 %
Double Flap Towards product
Valve
Elevator
35 % False air
No air
inlet! Airslide
False air
A consequence of under-ventilation
• Under-ventilated mill
• air flow over the load: 0,8 m/s, hot clinker
• Consequences
• mill outlet temperature 124 °C
• plaster false set due to excessive gypsum dehydration
3,35% of semi-hydrate instead of 1%!
Water Injection
Water Injection
N O IN J E C T IO N IN J E C T IO N
IN L E T /O U T L E T
ºC ºC
S lo t b lo c k a g e
•Dehydration of gypsum S lo t b lo c k a g e
•Slot blockage
InInnneeffic
DDeehhy yddraratatatiotionnoof fggy ypps suumm fficieiennc cy yinin
•Coating •Inefficiency inddeeddedusting
CCooaatintingg duus stintinggeeqquuipipmmequipment
eennt t
•Low mill
LLoefficiency
owwmmillilleeffic
fficieiennc cy y •Temperature T e m p e
Toscillations ra tu re o s
e m p e ra tu re o s c ilac ila tiotionns s ventilation
affect
aaffe
ffec ctstsv veenntila
tilatiotionn
Spray Locations
1 2 3
• 1 - Feed end
• Mechanically simple, process problems
• 2 - Partition
• Can be mechanically problematic, best for process
• 3 - Discharge end
• Good if mill is weakly vented and/or short compartment or
only small amounts are needed
Thermal Profile
Illustration of Water Spray Effects
90
80
70
Mill Shell Temp, % Range
60
50
DE Water Spray
Partiton Water Spray
40
Compartment 1 Compartment 2
0 20 40 60 80 100 120
30
• Objective
• Decrease the temperature peak to avoid gypsum
dehydration when all action has been done on ventilation
• Current controls
• Cleaning the injection cane (good level of atomization)
• Stable flow injected
Agglomeration
Ball Coating
Ball Coating
Grinding Aids