You are on page 1of 49

This new MITSUBISHI CNC will guide you to

Upgraded Manufacturing.
MAZATROL SMART H/W Connection / Maintenance

MAZATROL SMART Series

CONTENTS
1. Control Unit connection
2. Key board connection
3. I/O interface Connection
4. MPG connection
5. LED conditions
6. Maintenance

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 2
MAZATROL SMART (H/W
H/W Connection )

1.Control unit:
Connectors Layout Drawing of Control Unit

INV DCIN EMG ADONCCB LCD

USB

CF

OPT LAN CG71 RIO1 MENUKEY SKIP SIO BAT

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 3
MAZATROL SMART (H/W
H/W Connection )

Connector list of Control unit

NAME FUNCTION CONNECTED CABLE


INV Backlight DC input Display unit F480
DCIN DC24V input Power Supply F070
EMG EMG input EMG Switch F120
ADONCCB Option unit I/F Option Card -
LCD LCD I/F Display unit G492
CF CF card I/F CF card -
OPT Drive system I/F Drive unit G395/G396/G380
LAN Ethernet I/F Net work G300/G301
CG71 I/O unit I/F Keyboard unit G011
RIO1 Remote I/O unit I/F Remote I/O Unit FCUA-R211
MENUKEY Menu key input Display unit -
SKIP SKIP I/F 8-ch Sensor FCUA-R030
SIO RS-232 I/F 8 -ch F034/F035
BAT Battery input Battery -
USB USB Memory I/F USB Memory -

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 4
MAZATROL SMART (H/W
H/W Connection )

2. Keyboard unit
 Operation Panel I/O card (HN354) is mounted on the back side of FCU7-YZ031/YZ032

HN354

NC Data Key I/F


( KBADON)

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 5
MAZATROL
MAZATROLSMART H/WConnection
SMART (H/W Connection)

3. I/O interface Connection


KBADON
3.1 Operation panel I/O MPG

CG71
RIO3

CG32 CG37

Connector list of HN354

NAME FUNCTION CONNECTED CABLE


MPG MPG I/F Manual pulse Generator F320/321,F023/024
KBADON NC Data Key I/F KS-7YZ211A-P G403
CG71 I/O unit I/F Control unit G011
RI03 Remote I/O I/F HR371-Y FCUA-R211
CG32 DO I/F
Machine Operation panel
CG37 DI I/F

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 6
MAZATROL SMART H/W Connection

3.1.1 Connection of Power Supply to Operation panel I/O


.

POWER
SUPPLY HN354
0V
+24V

0V

CG32 CG37
2A 1A 2A 1A
2B 1B 2B 1B

+24V

Note: +24Vdc power supply is necessary for both of the sink type and source type.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 5
MAZATROL SMART H/W Connection
3.2 Remote I/O Unit Sections Front view

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 8
MAZATROL SMART H/W Connection

① DI-L ( A connector for machine input signals )


② DS ( A switch to change transfer speed )
③ CS ( A switch to change the channel )
④ DO-L ( A connector for machine output signals )
⑤ RIO1 ( A connector for series connection #1 )
⑥ RIO2 ( A connector for series connection #2 )
⑦ DCIN ( A connector for DC24V power supply input )
⑧ AIO ( A connector for analog input/output signals )

3.2.1 Connection of Remote I/O Power


<Connection Outline>
 +24Vdc power is required for the remote I/O unit. power for the DI-L DI-L
control circuit is supplied from the connector DCIN.
B1
Front B2

A1
A2

+24V
B1
B2

0V
A1
A2

DO-L
Rear DO-L

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 9
MAZATROL SMART H/W Connection
3.2 Connection of FCUA-DX141 unit and analog I/O signal

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 10
MAZATROL SMART H/W Connection

ANALOG I/O connection Details

1 0V 11 0V
2 I AI 0 12 I AI 1
3 I AI 2 13 I AI 3
4 NC 14 NC
5 0V 15 0V
6 NC 16 NC
7 O AO 17 NC
8 NC 18 NC
9 NC 19 NC
10 NC 20 NC

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 11
MAZATROL SMART H/W Connection

3.3 Card-sized I/O Specification


 The Card-sized I/O can be used as operation board I/O or electric cabinet I/O.
The connector PCB for the card-sized I/O is provided by machine builder.
 The card-sized I/O powers (+24V and +5V) must be supplied from external power supplies

 Card-sized I/O doesn't have rotary switch for setting a channel number. Connect
SEL1~SEL3 signal pins of connector CF30 to +5V or 0V on base PCB

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 12
MAZATROL
MAZATROLSMART H/WConnection
SMART (H/W Connection)

4. Connection of Manual Pulse Generator


 Up to two manual pulse generators can be connected.
 5V power supply type connect the F023/024 cable,
 12V power supply type connect the F320/321 cable to "MPG" on operation panel I/O.

1) connect to 5V power supply type

Operation panel I/O

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 13
MAZATROL
MAZATROLSMART H/WConnection
SMART (H/W Connection)

2) connect to 12V power supply type

Operation panel I/O

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 14
MAZATROL
MAZATROLSMART H/WConnection
SMART (H/W Connection)

Input / Output Conditions of Manual Pulse Generator


90 degree phase difference between A and B. (Refer
Input pulse signal type
to waveform below)
H level 3.5V to 5.25V
Input pulse signal voltage
L level 0V to 0.5 V
Max. Input pulse frequency 100kHz
5VDC ± 10%
Power voltage for pulse generators
12VDC ± 10%
Max. output current 100mA
No. of pulses per rotation 25 pulse /rev or 100 pulse /rev

A Phase

B phase Phase difference=T/4±t/10


T :- A or B phase cycle ( Minimum 10μs )
T

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 15
MAZATROL SMART H/W Connection

Manual Pulse Generator connection details

1 0V 11 0V
2 NC 12 NC
3 I 2HA 13 I 2HB
4 I 1HA 14 I 1HB
5 0V 15 0V
6 12V 16 12V
7 NC 17 NC
8 NC 18 NC
9 NC 19 NC
10 5V 20 5V

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 16
MAZATROL SMART
MAZATROL SMART(H/W
H/WMaintenance)
Maintenance

5. LED Condition (Control unit)


7 segment LED for system status

NAME FUNCTION COLOUR STATUS


Normal Error
24VDCIN 24VDC being supplied Green ON OFF
DCOUT Internal power being output Green ON OFF
LCDON 12VDC being output Green ON OFF
PSEMG Power supply emergency stop Red OFF ON
WDER Watchdog error Red OFF ON
BATALM Low battery alarm Red OFF ON
COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 17
MAZATROL
MAZATROLSMART H/W Maintenance)
SMART (H/W Maintenance

5. LED Condition ( Keyboard unit )

RIOWD1 RIO1 12VON

24VON
PACKETNG 5VON
FUSE

STATUS
NAME FUNCTION COLOUR
Normal Error
24ON 24VDC input status for DI/O Green ON OFF
FUSE Fuse status Green ON OFF
RIOWD1 RIO watchdog error Red OFF ON
PACKETNG RIO packet error Red OFF ON
RIO1 In RIO communication Green ON OFF
5VON 5VDC input status Green ON OFF
12VON 12VDC output status Green ON OFF

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 18
MAZATROL SMART
MAZATROL SMART(H/W Maintenance)
H/W Maintenance

6.1 Maintenance (exchange of fuses)


Fuses are mounted on Control unit and Keyboard unit respectively.
Please exchange fuses when the following phenomenon occurs.
(1) Control unit
NC doesn’t work and “24VDCIN” LED ON though 24V is normally supplied.
(2) Display unit
Machine panel doesn’t work normally, and “FUSE” LED OFF and “24VON”LED ON

(1)Control unit (2)Display unit

F1 (LM40)

(1) “24VDCIN” OFF

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 19
MAZATROL SMART
MAZATROL SMART(H/W
H/WMaintenance)
Maintenance

6.2 Maintenance (exchange of battery)


One battery is mounted on Control unit. Please exchange battery
when the following phenomenon occurs.
(1) “BATALM”LED lights and “BATTERY ALARM” appears on the

display.
(2) Parameter (SRAM data) is broken
※Attention 52 BATTERY ALARM
a) Backup the SRAM data before exchange of battery
b) Control unit power turn off
c) Replace the battery within 30 minutes after turn off the power

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 20
MAZATROL SMART H/W Maintenance

6.3 Attention by cable connecting


Please note the connection of the cable because the shape of three connectors are same.
(Especially, when the cable for SKIP is done another connector in, it causes the substrate
damage.)

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 21
MAZATROL SMART H/W Maintenance

6.4 Basic Operations for Maintenance


Unlocking the Password Key Lock
The functions and screens that cannot be operated by the user are locked with a password
key, and normally cannot be used

Releasing the Key-lock


Follow the below procedure to unlock the key. Once the key-lock is released, the key is
remained unlocked until the power is turned OFF. When the power is turned ON again, the
key will be automatically relocked

(1) Select [DIAGNOS] and [VERSION].

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 22
MAZATROL SMART H/W Maintenance

(2) Press the menu selection key , and press keys in the order of

1 1 3 1 INPUT

Following the operation above, the [Hidden] screen menu will appear when the menu selection
key is pressed

Screen Menu
selection key Menu key selection key

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 23
MAZATROL SMART H/W Maintenance

6.5 Normally (locked with password key) Prohibited Operations

1. Setting of forced output

2. Setting of servo parameters and spindle parameters

 Parameter setting menu


 Servo Parameter window
 Spindle Parameter window

3. Setting of system parameters (SYSTEM PARAM) and pitch error compensation (PITCH
ERROR), and display of key history (KEY HISTORY) and memory scope (MEMORY
SCOPE) ,Setting of cutting parameter (CUTTING PARAM)

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 24
MAZATROL SMART H/W Maintenance

6.6 Backing up the Saved Data


All the data stored in SRAM, the data indicating the customer's machine conditions can be
backed up by data input/output on NC screen.

Type of the saved data

1 Machining program 6 Work piece offset

2 Tool data 7 User parameter

3 Tool offset 8 Machine parameter

4 Jaw shape 9 Macro variable

5 Cutting condition 10 Periodic inspection

Media for backing up the saved data

The available media for backing up the saved data is a CF card only (NC's front side slot).
Use a CF card via the NC's front side slot to back up the data

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 25
MAZATROL SMART H/W Maintenance

Backing up the saved data


1) Press the screen selection key until the menu in the figure below appears, and select
[DATA I/O] from the menu

(2) Input / Output the data via the screen below.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 26
MAZATROL SMART H/W Maintenance

(3) Press the [CARD] menu.


(4) When the [DIR. SELECT] menu is pressed, the folders in the selected drive are displayed
in the [SELECT DIRECTORY] window. Choose the folder to input/output data.
・ When a folder is newly created, directly input a folder name using the keys.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 27
MAZATROL SMART H/W Maintenance

The selected folder name is displayed in <<DIRECTORY>> on the right side, when [OK]
is clicked or when <INPUT> is pressed.

(5) Select [NC->CARD SAVE], and select the data to output.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 28
MAZATROL SMART H/W Maintenance

(6) Selecting the program file


Press the [SELECT ALL] menu and press <INPUT>. And then, all the program files are
displayed in the program area on the upper left.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 29
MAZATROL SMART H/W Maintenance
(7) Selecting the other data
Use the down arrow key to move the cursor from PROGRAM area to OTHER DATA area .
Press <INPUT> to select and highlight all the items.

(8) Press the [START] menu to start copying.


The output status is displayed sequentially in the selected directory column on the right side.
The copy is completed when the directory column becomes the same as [NC] on the left side

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 30
MAZATROL SMART H/W Maintenance

6.7 Restoring the saved data


Follow the steps (1) to (5) in the previous section to set the CF card's folder name.
(6) Selecting the backup data
Select [CARD CONTENT] and [START] from the menu. And then the contents of the selected
folder are listed on the right side column.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 31
MAZATROL SMART H/W Maintenance

(7) Loading the selected data


When the [NC<-CARD LOAD] and [START] menu are pressed, the selected data is loaded to NC.
The output status is displayed sequentially in the [NC] column on the left side. The loading is
completed when the NC column display becomes the same as the CF card directory column on
the right side.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 32
MAZATROL SMART H/W Maintenance

6.8 Backup/ Restore the Ladder

The ladders stored in the NC's FLROM can be output to external medium by ladder monitor.
The ladders stored in the external medium can also be input to the NC's FLROM.

6.8 LADDER Backup Procedure.

Step 1. Release the Key-lock .


Step 2: Press LADDER MONITOR menu

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 33
MAZATROL SMART H/W Maintenance

Step 3. Press EXT. FILE operation Menu


Step 4: Press NC – EXT Menu

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 34
MAZATROL SMART H/W Maintenance

Step-5:Confirm that all


items are being selected, Step:6 - Input the project name to save.
and select [WRITE] -Execute [SAVE].

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 35
MAZATROL SMART H/W Maintenance
LADDER Restore Procedure.
Step 1. Release the Key-lock .
Step 2: Press LADDER MONITOR menu

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 36
MAZATROL SMART H/W Maintenance

Step 3:- FORMAT the ladder memory location.


Step 4:-Go back to MAIN menu and select [ EXT-
FILE OPERATION]

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 37
MAZATROL SMART H/W Maintenance

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 38
MAZATROL SMART H/W Maintenance

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 39
MAZATROL SMART H/W Maintenance

6.9 Initializing the Data


(1) Turn the NC power ON.
(2) Press the screen selection key until the following menu appears. Select the [DIAGNOS]
and [DATA ERASE] menu.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 40
MAZATROL SMART H/W Maintenance

(3) Using the arrow keys and INPUT key, enable the initialization of all data on the displayed window
(highlight them in light blue).

(4) Follow the message under the data selection field, input "-9999" and press the INPUT key.
The initialization is completed when the DATA ERASE window display disappears.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 41
MAZATROL SMART H/W Maintenance

6.10 Initializing the programs

The initialization procedure of the area where the machining program is stored is shown below
.
(1) Turn the NC power ON.

(2) Press the screen selection key until the following menu appears. Select [PROGRAM]→
[PROGRAM FILE]→[PROGRAM ERASE] from the menu.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 42
MAZATROL SMART H/W Maintenance

(3) Select (Highlight) [ALL ERASE] from the menu. Using the operation board keys, input "-9999" and then
press the INPUT key. Initialization of the programs is completed when the highlighted display of [ALL
ERASE] returns to the normal display.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 43
MAZATROL SMART H/W Maintenance

6.11 Erasing the Memory


The procedure for erasing the SRAM is described
below
.
(1) Set the NC rotary switch 2 [RotSw2] to "C". Keep
the rotary switch 1 [RotSw1] at "0".
(See the right images.)

(2) Turn the NC power ON. The seven-segment LED 1


(on the right side) changes as shown below.
The procedure is completed when "Y" appears.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 44
MAZATROL SMART H/W Maintenance

(3) Turn OFF the NC power.

(4) Return the rotary switch 2 to "0".

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 45
MAZATROL SMART H/W Maintenance
6.12 Data with Special Operations
Setting the date and time
(1) Select (Highlight) [DIAGNOS] -> [ACCUMU.TIME] to open the [ACCUMULATED TIME] window.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 46
MAZATROL SMART H/W Maintenance
(2) Move the cursor to [DATE] using the cursor keys.

(3) Input the date to be set, and then press the INPUT key to complete the setting.

Example: January 1, 2000

(4) Set the time in the same manner.

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 47
Thank you for Listening

COPY RIGHT : 2011 MITSUBISHI ELECTRIC INDIA PVT. LTD. ALL RIGHTS RESERVED 48
This new MITSUBISHI CNC will guide you to