You are on page 1of 59

201.

A vent in a combustion waste and vent system shall be approximately


equal in area to one half.

a. Area of the house sewer

b. Cross section area of the draw pipe

c. Area of the public sewer

d. Diameter of the draw pipe served


202. DWV material means

a. Drainage, water vents

b. Drainage water valve

c. Drum waste valve

d. Drainage, waste and vent


203. Every passageway to an attic water heater shall have a solid continuous
flooring not less than

a. 36 inches wide

b. 48 inches wide

c. 60 inches wide

d. 24 inches wide
204. Every building in which plumbing fixture are installed shall have
connection to a :

a. Deywell

b. Cesspool

c. Storm sewer

d. Public or Private sewer


205. Allowing for friction and other pressure loss the available water pressure
for fixture is

a. 30 psi

b. 20 psi

c. 15 psi

d. 45 psi
206. The movement of water to the surface of a soil and into the soil below the
surface is

a. Storm meter run off

b. Depression

c. Evaporation

d. Infiltration
207. The size of supply piping outlet for any gas appliance shall be not less
than

a. The smallest size pipe in the system

b. The inlet connection of the appliance

c. ¾ inch of total length is 30 ft

d. One inch to allow future expansion


208. The quantity of water required to be supplied to every plumbing fixture
shall be represented by:

a. Pound per square inch

b. Gallons per minutes

c. Fixture units

d. Feet per second


209. A pit or receptacle at a low point to which the liquid waste are drain

a. Canal

b. Sump

c. Tank

d. Cistern
210. A fixture vent pipe increased one pie size its entire length

a. May exceed the maximum horizontal length limited by code

b. Will be better workmanship job

c. Will increase venting efficiency

d. Will reduce the cost of installation


211. Fee for one unit of plumbing as plumbing permit is:

a. P 5.00

b. P 15.00

c. P 12.00

d. P 10.00
212. A storm drain sometimes located under the basement floor within the
walls of the building

a. Inside storm drain

b. House sewer

c. Outside storm drain

d. Inside sewer
213. What is the interval distance between clean-out along lateral line?

a. 15 m

b. 48 m

c. 10 m

d. 6 m
214. Which type of fire line installation has become obsolete and seldom
installed?

a. Automatic system

b. Wet standpipe

c. Local vent

d. Dry standpipe
215. Generally, what is the standard diameter of standpipe for buildings more
than six stories tall?

a. 9”

b. 4”

c. 6”

d. 10”
216. A pressure regulator should be installed when pressure exceeds

a. 75 psi

b. 80 psi

c. 85 psi

d. 90 psi
217. What is the copper content in brass fitting?

a. 80%

b. 85%

c. 90%

d. 95%
218. Is a device located at the bottom of the tank for the purpose of flushing
water closet and similar fixtures

a. Gate valve

b. Flush valve

c. Flushometer valve

d. Flush tank
219. The lowest portion of the interior part of any pipe or conduit that is not
vertical

a. Leader

b. Lateral

c. Grade

d. Invert
220. What is the maximum height for the Hose Cabinet to be installed from
the floor line?

a. 6 ft

b. 8 ft

c. 5 ft

d. 4 ft
221. A structure built, erected and framed of component structure parts
designed for the housing, shelter, enclosure or support of person, animals or
property of any kind.

a. Building

b. Catch basin

c. Court

d. Park
222. A pipe connected from building gutter to the downspout

a. Header

b. Conductor

c. Latrine

d. Privy
223. A term used to described soil or waste system where all piping are
threaded pipe tubing or other rigid construction using recessed drainage
fitting to correspond to the types of piping

a. Drainage System

b. Durham System

c. Piping System

d. Waste Pipe System


224. Generally, what is the standard diameter of standpipe for buildings two
or three stories in height?

a. 4”

b. 6”

c. 3”

d. 2”
225. The pressure available at the fixture or water outlet, allowance is made
for pressure drop due at friction loss, head, meter and other losses in the
system during maximum demand period

a. Pressure

b. Residual Pressure

c. Static Pressure

d. Pressure Loss
226. In a line of piping is a combination of elbows or bends, which brings one
section of the pipe out of line but into a line parallel with the original section.

a. Dead end

b. Offset

c. Drain

d. Flooded
228. A non-watertight lined excavation in the ground which receives the
discharge of a sanitary drainage system or part thereof, designed to retain the
organic matter and solids discharging therefrom, but permitting the liquid to
seep through the bottom and sides of the cesspool.

a. Chase

b. Cesspool

c. Privy

d. Receptor
228. A non-watertight lined excavation in the ground which receives the
discharge of a sanitary drainage system or part thereof, designed to retain the
organic matter and solids discharging therefrom, but permitting the liquid to
seep through the bottom and sides of the cesspool.

a. Chase

b. Cesspool

c. Privy

d. Receptor
229. An approved plumbing fixture or device of such materials, shape and
capacity to adequately receive the discharge from indirect waste pipes,
constructed and located to readily cleaned

a. Rim

b. Receptor

c. Riser

d. Revent Pipe
230. The normal force exerted by a homogeneous liquid or gas per unit of
area on the wall of the container

a. Pitch

b. Static head

c. Friction loss

d. Pressure
231. An impairment of the quality of the water to a degree which creates
hazard to the public health and adversely affects the aesthetic and potable
qualities of waters for domestic use.

a. Pollution

b. Quality of water

c. Potable water

d. Defects
232. Tube made of plastic material and colored black. The cross-sectional
shape is circular and is denotes by its outside diameter or O.D.

a. PB or Polybutylene

b. PVC or Polyvinylchloride

c. PE or Polyethylene

d. ABS or Acrylonitrile-Butatiene-Styrene
233. In what year, NAMPAP President Jaime M. Cabase spearhead the
updating of the Revised National Plumbing Code?

a. 1999

b. 2003

c. 1980

d. 1996
234. Number of lavatories for Assembly Places(Theather, Auditorium,
Convention Halls,etc) for public use for 350-female

a. 1

b. 2

c. 3

d. 4
235. In 1902, he was the first Chief of Plumbing Construction and Inspection

a. Emilio Aguinaldo

b. John F. Hass

c. Ramon Magsaysay

d. General Harrizon
236. Consists of a loaded air inlet valve, an internally loaded check valve, two
properly located test cocks and two isolation gate valves.

a. PVB or Pressure Vacuum Breaker Backflow Prevention Assembly

b. RP or Reduced Pressure Principle Backflow Prevention Assembly

c. DC or Double Check Valve Backflow Prevention Assembly

d. AVB or Atmospheric Vacuum Breaker


237. Number of urinal for Office for 420 person

a. 5

b. 2

c. 4

d. 7
238. Revised Plumbing Code of 1999 was approved by President Joseph
Estrada

a. December 21,1999

b. October 12, 1999

c. June 2, 1999

d. August 18,1999
239. Plumbing Code for the City of Manila

a. City Ordinance 4121

b. City Ordinance 1124

c. City Ordinance 2411

d. City Ordinance 1241


240. Drainage Fixture Unit of water closet, public installation

a. 6

b. 3

c. 4

d. 1
241. When President Ramon Magsaysay did signed the R.A. 1378, otherwise
known as the “PLUMBING LAW OF THE PHILIPPINES”?

a. June 8, 1959

b. June 28, 1699

c. June 18, 1955

d. June 8, 1599
242. Type of Joints for soft copper water tubing shall be made with fittings
meeting approved standards. The tubing shall be expanded with a proper
flaring tool.

a. Flared joints

b. Solder & Sweat joints

c. Cement Mortar Joints

d. Burned Lead Joints


243. National Plumbing Code prepared by NAMPAP was Promulgated and
approved by Malacanang

a. June 18, 1955

b. June 8, 1959

c. January 28,1959

d. January 18, 1955


244. Drainage Fixture Unit of sink, bar, private 38 mm min waste

a. 1

b. 2

c. 3

d. 4
245. Birth of Plumbing practice in the Philippines

a. 16th Century

b. 17th Century

c. 18th Century

d. 19th Century
246. Approval of House Bill No. 962 also known as RA No. 1378

a. 1978

b. 1852

c. 1954

d. 1935
247. The indirect waste lines carrying refrigeration waste shall not be smaller
than one (1) inlet serving not more than 2.8 mm3 of refrigeration space.

a. 32 mm

b. 51 mm

c. 76 mm

d. 62 mm
248. Each grease trap shall have an approved water seal of not less than
_____in depth or the diameter of its outlet, whichever is greater

a. 38

b. 64

c. 76

d. 51
249. Cleanouts may omitted on short horizontal drainage pipe installed at a
slope of _____ or less from the vertical line ( or an angle _____bend) and;

a. 72 degree ; 1/5 bend

b. 45 degree ; 1/8 bend

c. 60 degree ; 1/6 bend

d. 22 ½ degree; 1/16 bend


250. Sizing of rainwater piping for two adjacent walls- add _____of the total
wall areas to the roof area

a. 45 %

b. 50%

c. 60 %

d. 35%
251. Access to each septic tank shall be provided by at least two(2) manholes
_______ in minimum dimension or by an equivalent removable cover slab.

a. 545 mm

b. 508 mm

c. 450 mm

d. 445 mm
252. All septic tank covers shall be capable of supporting on earth load of not
less than ______ when the maximum coverage does not exceed 9m.

a. 14.4 kPa

b. 15.3 kPa

c. 18.3 kPa

d. 16.2 kPa
253. Interceptors or clarifiers for sand and similar heavy solids shall be so
designed and located as to be readily accessible for cleaning and shall have a
water seal of not less than ____ deep.

a. 152 mm

b. 120 mm

c. 135 mm

d. 145 mm
254. Air test, air is forced into the pipe system until there is a uniform gauge
pressure of _____ or sufficient to balance a column of mercury 254 mm in
height.

a. 34.5 kPa

b. 43.5 kPa

c. 35.4 kPa

d. 45.3 kPa
255. No galvanized wrought iron or galvanized steel pipe shall be used
underground and shall be kept at least ___ above ground.

a. 125 mm

b. 150 mm

c. 152 mm

d. 251 mm
256. Dome-type strainers shall have a minimum total net inlet area of
________times the area of the outlet pipe to which it is connected.

a. One and one-half

b. Two and one-half

c. One

d. Two
CONGRATUALATION
YOU ARE NOW A
REGISTERED MASTER
PLUMBER
SORRY YOUR
FAILED ……..
Thank You …..

You might also like