You are on page 1of 58

1

Quarterly Update Q-2 2021 BYONYKS


BLOODLESS DIALYSIS
52 year back
2

1969

Today, 52 years
3
4
5

HEMO
DIALYSIS
PERITONEAL
DIALYSIS ?
? 6

BREAK THROUGH
TREATMENT?

SELF MIXING
DIALYSATE

REUSABLE
DISPOSABLE
7

PROGRESS REPORT
BASE LINE MACHINE
FACTORY
PRODUCT Pure Vanilla Ice Cream
APP - IOT Basic Automatic
Peritoneal Dialysis Machine
8

FACTORY
9

MANUFACTURING
PLANT
• Manufacturing Site Leased (Complies with
DRAP guideline)

• Structural & civil design/drawings and


process flow design completed

• Work already started

• Some production machines ordered


MANUFACTURING
PLANT LAYOUT

10
11

MANUFACTURING PLAN 3D MODEL


Medical grade flooring & walls underway No cost to us - expansion of 2nd hall by owner
MANUFACTURING PROGRESS
Medical grade flooring & walls underway No cost to us - expansion of 2nd hall by owner
MANUFACTURING PROGRESS
Medical grade flooring & walls underway No cost to us - expansion of 2nd hall by owner
EXTRUDER TESTED IN CHINA
BEFORE SHIPMENT

14
Machines in Transit

TUBE STERILIZED
EXTRUDER CHAMBER

15
16

PRODUCT
Bloodless Dialysis Machine
Disposable Kit
SENSING SUB-SYSTEMS
Patient MPX
Pressure Sensor

Loadcell pressure
Sensor
Pressure Sensing Sub-systems
Patient Side:
1. MPX Pressure Sensor - Primary
LED pressure
2. Loadcell Sensor - Secondary
Sensor
3. LED Sensor – Tertiary
All these systems measure both the
negative and positive pressure form
the patient.
Source Side:
1. MPX Pressure Sensor
MPX Chamber

Source MPX
Chamber
18

Enclosure
for first 100 machines
Enclosure
for first 100 machines

19
20

Enclosure
21
22
23
24
25

https://youtu.be/25ZuKkbHdqM?t=126
BYONYKS APP
27
28

BYONYKS APP
29

Make machine
Test runs
30

REGULATORY CERTIFICATES
31
32

REGULATORY AFFAIRS
33

SIGNED
MOU
34

DRAP APPROVAL PROCESS & FDA/CE


PREPARATIONS
DRAP Process FDA & CE Preparation
• We are engaged and working with • Consultants hired in USA to prepare
DRAP on a regular basis exhaustive documents to meet
requirements
• Manufacturing approval received
• ISO and other certifications required
by FDA have been started
35

PATIENT
36

PATIENT TREATMENTS
• The female patient had volume overload issues. • APD therapy is performed twice a week
• Good UF results • Better UF and the patient is feeling quite satisfied
• Satisfactory results • He cannot wait to have it at home!

https://pk.mashable.com/video/4821/whatsa pp-video-2020-08-26-at-120521-pmmp4
BAHRIA
INTERNATIONAL
HOSPITAL

37
38

IP Protection
US
Pakistan
&
International
IP Protection in the US

• 2 Design patents filed


• 8 PPA
• 4 Trademarks

IP Protection in Pakistan

• 2 Patents filed
• 8 Trademarks – 1 got registered
• 4 Copyright

International Filing

• 1 Design Patent – WIPO (UK, EU, Canada)


• 2 PCT applications
40

THE TEAM
BIGGEST ASSET IS OUR STRONG TEAM WORKING TOGETHER!
THE
TEAM
42

SALAHUDDIN KHAN
43
44
45
46
47

RENACON PHARMA
48

SIGNED MOU
49

Q&A
GANTT CHART
(START OF PRODUCTION AUGUST 11, 2021)

50
51

PRODUCT
Bloodless dialysis machine
Disposable Kit
52
53
54

FUTURE
Tubes to MPX
Chamber

1. MPX PRESSURE
SENSOR MPX Pressure
Sensors

• Fluid in the cassette acts


against the membrane Trapped Air
which then acts against
Trapped air in MPX
Chamber.
• MPX Pressure sensor reads
4 kPa against 15kPa in
Cassette which is then
regressed. MPX Chamber
• O-ring protrusion from
surface is 0.5 mm.
Cassette
2. LOADCELL
PRESSURE SENSOR Loadcell
Plunger
• A plunger is used for transmitting
the load from the membrane onto
the loadcell as shown in fig.
• The membrane is prestressed with
the plunger, this is to ensure that Loadcell
the membrane covers both
negative and positive pressure
range. Loadcell
• Based on the membrane behavior Cover
the load on the loadcell is either
increased or decreased, which is Plunger
calibrated against the pressure Nut
sensor.
Loadcell
Cartridge
57

TEAM BUILDING IN USA

Sheela Gayatri [Software]


Farzeen Christie [FDA]
Kevin Christie [Electrical]
Tyler Fontaine [Electrical]

Inline
Kelly Catale [Human Factors]
Kara Johnson [FDA]
3. LED PRESSURE SENSOR
• LED Is transmitting light onto
the membrane. Where a LED
reflective a surface is pasted.
• The reflected light is received
on a photodiode as shown in
fig.
• Received light intensity is
increased or decreased with
membrane deflection, which is
measured on the sensor.
• The received electrical signal is
calibrated to be used as
pressure sensor.

LED Pressure
LED Mount Photodiode
Sensor

You might also like