COLD DOWTHERM Flow into fridge GCA-850 Flow into fridge GCB-850 Flow into fridge GCC-850 Flow going to cold supply Flow into fridge GCD-850 Pressure going to cold supply Pressure in cold return % pressure control valve open Temp in cold return Temp going to cold supply FI-01 FI-02 FI-03 FI-06 FI-08 PI-06 PI-08 PIC-08 TI-22 TI-24
DRAW NO.
EIR-2-178-0293
DOWTHERM J PROPERTIES BELOW 0OF Temp. Heat Capacity C kJ/kgK 0 1.769 -20 1.714 -40 1.663 -60 1.616 -80 1.584 Saturated Liquid Properties Temp. Heat Capacity kJ/kg.K 1.584 1.769 2.023 2.315 2.636 3.04
HOT DOWTHERM Flow in hot supply Pressure in hot supply Pressure leaving hot return Temp leaving top of heater EAA-851 Temp leaving top of heater EAB-851 Temp in hot supply Temp leaving hot return Temp from balance line FI-01 PI-06 PI-11 TI-02 TI-03 TI-06 TI-08 TI-15
DRAW NO.
EIR-2-178-0294
TEMPERED DOWTHERM SYSTEM Flow leaving pump GA-852 Flow entering molecular sieve PAA-852 Pressure leaving pump GA-852 FI-01 FI-02 PI-03
DRAW NO.
EIR-2-178-0295
Temp leaving pump GA-852 % temp control valve open to cold dowtherm
TI-02 TIC-02
TEMPERED DOWTHERM DISTRIBUTION Pressure in 2nd floor header Temp in 2nd floor header PI-01 TI-04
DRAW NO.
EIR-2-178-0414
m . Cp . D T
m (kg/s) 56.05 Cp (kJ/kgK) 1.714 DT (K) 1.84 Q (kW) 176.78
Fridge Loading
PERTIES BELOW 0OF Density kg/m3 878.5 892.9 907 921 931.3
operties Density kg/m3 931.3 878.5 817.4 749.2 668.8 560.4 Thermal Conductivity W/mK 0.1485 0.1326 0.1156 0.0987 0.0817 0.0647 Viscosity mPa.sec 8.43 1.23 0.47 0.28 0.2 0.16 Vapour Pressure bar