INVESTMENT PROPOSAL M/s. . Kind Attn: Mr Offer No.

CCPL/MDS/SCVS/KGD/007/2012-13

Offer Date Dear Sir, Enquiry Ref. With reference to the enquiry, we are submitting our Handled by best offer for your perusal. Validity Sl NO. Description
MAKE: CONSUL STABILISER WITH ISOLATION TRANSFORMER

02.07.12 Mail dt. 02.07.12 K.G. Deenadayalan 99401 72533. 30 days Rate (Rs.) Per unit TOTAL Amount

Qty.

01.

CAPACITY 15KVA 3PHASE Stabilizer with Isolation Transformer Model : Air Cooled Input : 295-465V Output : 415V

P&F @2% EXTRA

Excise Duty Extra @ 12.36%

Vat / CST Extra @ 14.5%

Prices F.O.R CHENNAI

Octroi/Entry Tax If applicable extra at actual

FREIGHT TO PAY

Warranty: 12 months from the date of invoice. Delivery: 3-4 Weeks from the date of receipt of technically and commercially clear purchase order.

Order to Be placed on : Consul Consolidated Pvt. Ltd., 4/329 A Old Mahabalipuram Road, Chennai- 600 041. Order to be sent to: Consul Consolidated Pvt. Ltd., No.: 44/19,3rd Floor, Krishnasree Enclave , First Main Road, Gandhi Nagar, Adyar, Chennai 600 020.

INSTALLATION & COMMISSIONING FREE OF COST

Terms of payment: 50% ADVANCE & BALANCE AGAINST DELIVERY & RECEIPT OF MATERIAL AT SITE Please inform in your purchase order any legal / statutory or other requirements to be followed as vendor of the above products INSTALLATION: Any civil work for site preparation is not For CONSUL CONSOLIDATED (P) LTD in scope of this proposal. The end customer will provide all the power cables & switchgear for input and output. K.G. Deenadayalan 99401 72533.

SPECIFICATIONS OF STABILISER: RATING INPUT RANGE OUTPUT VOLTAGE INPUT FREQUENCY CORRECTION SPEED RESET METERING PROTECTIONS : : : : : : : : 15KVA 295-465V 415V +/-1% 47 TO 53 Hz AVERAGE 70V PER SECOND PHASE TO PHASE MANUAL (OR) AUTO RESET WITH TIME DELAY TO DISPLAY VOLTAGE / CURRENT / FREQUENCY ELECTRONIC OVER & UNDER VOLTAGE TRIP WITH TIME DELAY & OVERLOAD PROTECTION PROVIDED FOR TRIPPING CONDITIONS AIR COOLED NON-LATCHING INDICATIONS CAUTION INPUT HIGH /INPUT LOW SIEMENS GREY >98% INPUT AND OUTPUT CABLE TERMINATIONS WITH PROVISIONS FOR FIXING CABLE GLANDS. RUGGED AC STEP SYNCHRONOUS MOTOR. 0 DEGREE 45 DEGREE CENTIGRADE. UNI DIRECTIONAL FOR AIR COOLED

SINGLE PHASE PREVENTOR AUDIO ALARM NATURE OF COOLING ANNUNCIATION PANEL

: : : :

COLOUR OF CABINET EFFICIENCY PROVISION OF CABLING

: : :

SERVO MOTOR DRIVE OPERATING TEMPERATURE WHEEL

: : :

TECHNICAL SPECIFICATION OF IT: RATING MODEL NATURE OF COOLING INPUT OUTPUT CORE CABINET WHEEL TERMINATION COLOUR OF CABINET PROVISION OF CABLING : : : : : : : : : : : 15KVA 3PHASE ISOLATION TRANSFORMER AIR COOLED 415V 415V FIRST QUALITY LAMINATOIN M.S CLOSED CABINET UNI- DIRECTIONAL WHEELS PROVIDED INPUT& OUTPUT TERMINATION SIEMENS GREY INPUT AND OUTPUT CABLE TERMINATIONS WITH PROVISIONS FOR FIXING CABLE GLANDS OPERATING TEMPERATURE REGULATION CONNECTIONS OPERATING POWER FACTOR DIELECTRIC STRENGTH COUPLING CAPACITANCE DC GALVONIC ISOLATION LINE LEAKAGE CURRENT NOISE ATTENUATION : : : : : : : : : 0 DEGREE 45 DEGREE CENTIGRADE. 2-4% FOR 100% CHANGE IN CURRENT AT UNITY P.F DELTA / STAR FOR 3 PHASE 0.75 LAGGING TO 0.75 LEADING 2500V FOR 60 SECONDS 0.1 PICO FARADS GREATER THAN 50 MEGA OHMS LESS THAN 5 MILLI AMPS 100 DB MAXIMUM = 1/1,00,000