GENERAL GUIDELINES FOR SELECTION OF INSTRUMENTS IMPULSE PIPES & FITTINGS AND WELDING ELECTRODES
SL. No I MAX. PR MAX. TEMP UPTO 400 DEG. C UPTO 350 DEG. C UPTO 540 DEG. C UPTO 550 DEG. C UPTO 560 DEG. C NOMINAL BORE 1 1 2 1 1 2 THICKNESS (SCHEDULE) SEC 40 - DO - DO - DO SEC 40 SCH 80 - DO - DO SCH 160 MATERIAL SPECIFICATION FITTING RATING FITTING MATERIAL SPECIFICATION FORGED CORBON STEEL ASTM A-105 GR.II FORGED CORBON STEEL ASTM A-105 GR.II FORGED STAINLESS STEEL ASTM A182 GR.F 316 - DO - DO RECOMMENDED ELECTRODE AS PER AWS CLASSIFICATION E6013

UPTO 42 KG / SQ CM UPTO 250 KG /SQ CM UPTO 155 KG /SQ CM UPTO 190 KG /SQ CM UPTO 250 KG /SQ CM

CARBON STEEL AS PER ASTM, A-106 GR.B ANSI B-16 SEAMLESS 3000 LBS CARBON STEEL AS PER ASTM, A-106 GR.B ANSI B-16 SEAMLESS 6000 LBS ALLOY STEEL ASTM, A-312, GR.P11 SEAMLESS STAINLESS STEEL ASTM A312 GR. TP 316 ALLOY STEEL ASTM, A-335, GR.II SEAMLESS - DO -

II

E6013

III

E8018 B2

IV V

SCH 160 SCH XXS

- DO - DO -

E309 E9018 B3

SCHEDULE as per ANSI B-36, 10/IS-1239 PART-I Note : 1) Above are only recommendation. Refer contract Drawings for details 2) For approved brands of Welding Electrodes refer latest list of rationalized electrodes or Welding Manual 3) For Electrode drying procedures, refer Welding Manual