Introduction ................................................................................................................. 1
Systems Approach ....................................................................................................................... 2 Graphical User Interface ............................................................................................................. 3

Installation ................................................................................................................... 5
CD Installation ............................................................................................................................ 5 Users Manual and Online Help .................................................................................................. 5

QuickStart .................................................................................................................... 6 Using ISET 2.0 ............................................................................................................ 8


Session Window ........................................................................................................................... 8 Scene ............................................................................................................................................ 9 Optics.......................................................................................................................................... 18 Sensor.......................................................................................................................................... 25 Processor..................................................................................................................................... 33

ISET Programming Guide ........................................................................................ 45 ISET Scripts and Application Notes......................................................................... 46 Glossary and Formulae .............................................................................................. 48 Appendix .................................................................................................................... 49
A. Matlab Data Conversion Routines ...................................................................................... 49

ISET

USER

MANUAL

Introduction
ISET is designed to help clients evaluate how imaging system components and algorithms influence image quality. ISET is a software package developed by Imageval Consulting, LLC. Using ISET the user can measure and visualize how changes in image systems hardware and algorithms influence the quality of the image. The software allows the user to specify and explore the influence of physical properties of visual scenes, imaging optics, sensor electronics, and displays on image quality. ISET is a unique tool that lets the user trace the effects of individual components through the entire imaging system pipeline. The software package uses a Graphical User Interface (GUI) to enable the user to intuitively and efficiently manipulate the various components within the image systems pipeline. Through this simple-to-use interface, the user can specify the physical characteristics of a scene including the viewing conditions (e.g. radiance, viewing distance, field-of-view, etc), and define many parameters of the optics, photodetector, sensor electronics and image processing-pipeline. ISET also allows the user to make quantitative characterizations of the individual components within the image systems pipeline. The package includes methods of calculating optical MTFs, pixel and sensor SNR, and color tools based on international standards (CIE chromaticity coordinates, color matching functions, CIELAB metrics and others) to evaluate the image quality of the processed image. Based on the Matlab development platform and open-software architecture, ISET is extensible and all of the data are accessible to users who wish to add proprietary computations or who simply wish to experiment.

4/20/2007

ISET

USER

MANUAL

Systems Approach
People judge an imaging system based on the final output rendered on a display or a printer. But the quality of the rendered output is determined by the sequence of image transformations that occur before and during image rendering. To identify the source of a visible distortion, we need to simulate and evaluate the entire imaging system, from image capture to image processing, transmission, and rendering. ISET simulates a complete imaging system beginning with a radiometric description of the original scene, optical transformations, sensor capture, and digital image processing for display. The user explores the image system properties using a suite of integrated windows that allow the user to view and alter the key physical objects in the image systems pipeline. The key elements are referred to as the Scene, Optics, Sensor, and Processor.

4/20/2007

ISET

USER

MANUAL

Graphical User Interface


ISET consists of a suite of integrated windows that allow the user to view and alter the key physical objects in the image systems pipeline. The principal windows are referred to as the Scene, Optics, Sensor, and Processor. ISET is launched from a Matlab command window by typing ISET. This begins a Session, which is an integrated record of the Scene, Optics, Sensor and Processor objects and their properties. The program opens a small window that allows the user through control of the main steps in the imaging pipeline. The program also creates a Session variable that is used to store the data created and analyzed during program execution. Each Session can store multiple objects making it easy for the user to switch back and forth between parameter settings and compare results as parameters and processing change. To create or edit different objects, the user opens a window designed to interact with that type of object. The windows controlling each of the objects are organized by a set of pull-down menus and editable boxes. The Pull-Down Menus in all of the object windows are organized in a similar, familiar way File: This menu allows users to load and save the information defined in each window. Edit: This menu allows users to delete, rename or edit properties of the objects associated with that window. Plot: This menu enables the user to plot data associated with the current object. For example, the user can select and plot the radiance in any area in the Scene window. The user can plot the optical transfer function, pointspread and linespread functions in the Optics window. The user can plot the spectral data for filters and sensors used in the current Sensor window and the data characterizing the display properties associated with the current Processor window. Scene, Optics, Sensor, Processor: Each window has a pull-down menu for importing data sets and adjusting the parameters of the object specific to that window. The Scene window has a pull-down menu labeled Scene to select the scene or targets. The Optics window has a pull-down menu labeled Optics to load optical parameters for standard optical formats.

4/20/2007

ISET

USER

MANUAL

The Sensor window displays a pull-down menu labeled Sensor to load sensor parameters of CIF, VGA or customized sensors that are stored in a file. And, finally, the Processor window has a pull-down menu for loading display parameters such as the spectral power distribution of color channels, the spatial layout of pixels, the display gamma, etc. Analyze: Each window has a menu that lets users calculate various metrics and measurements. For example, the user can select and plot the CIE chromaticity coordinates for areas in the Scene and Optics images. The user can create 3D pseudo-color coded images that represent the luminance and illuminance in the Sensor and Optics images. The user can calculate and plot Line, Region of Interest and SNR statistics for the Sensor image. And the user can calculate color image quality metrics (such as CIE E) and spatial image quality metrics (such as DCTune and PSNR) for the Processor image. Help: The help menu directs the user to an online manual page that describes the functionality of that window. Each window has an editable box for specifying the display gamma for the monitor that the window is displayed on. This has the effect of changing the appearance of the image displayed in the window, but it does not influence the underlying data. Each window has buttons and editable boxes for specifying properties associated with the current object. For example, the user can specify the physical dimensions of the scene, F-number and focal length of the optical lens, sensor noise properties, color filter array, color image processing algorithms, etc. The properties that users can specify and measure are listed for each window in the separate sections below for Scene, Optics, Sensor and Processor.

4/20/2007

ISET

USER

MANUAL

Installation
CD Installation
To install the ISET software, perform the following three steps. 1. Copy the contents of the ISET directory from the ISET-CD into a suitable location on your computer. We suggest placing the distribution inside of the users Matlab working directory, say C:\myhome\Matlab\ISET.2.0 2. Copy the file isetPath.m to a location that is always on your path when Matlab starts up. For example, place isetPath.m in C:\myhome\Matlab 3. Before running ISET, you must add the program and its sub-directories onto your path. To do this, you can simply type isetPath(C:\myhome\Matlab\ISET); 4. If you wish to run ISET routinely, you can put the isePath() command in your startup file.

Users Manual and Online Help


This user manual and related help files are maintained and updated online. A version of this manual in PDF format is also on the distribution CD in the Documents sub-directory.

4/20/2007

ISET

USER

MANUAL

QuickStart
If you like to explore software just by running it and exploring, we suggest you get started quickly by following these instructions. If you would rather read more about the software, please continue to the next section. Install the ISET tools on your Matlab path (see Installation). Enter ISET at the Matlab prompt. The Session window will appear. Press the Scene button. This will bring up a window in which you can create and explore various types of scenes. To get started quickly, under the Scene pull-down menu, select Macbeth D65. This will produce an image of a standard color test chart in the Scene window. Other test targets can be selected from the Scene pull-down menu, as well. Under the Plot pull-down menu, select Radiance. You will be asked to choose a region of the image using the mouse. Once you have done so, a graph window will appear showing the underlying spectral radiometric image data: The radiance of the scene at that location within the image. Return to the Session window and click on the Optics button. A new window will appear with a default set of assumptions about the optics. Click on the large Compute Optical Image button towards the bottom of the window; ISET will compute an image of the irradiance at the sensor and show an estimate of the image. You can plot the irradiance at the sensor, alter the parameters of the optics, and measure other features of the optical image, from this window. Next, return to the Session window and click the Sensor button. This will bring up a window with a default sensor. Clicking on the Compute Sensor Image button, will produce an image of the voltage responses across the surface of the default sensor. Using the Plot menu you can explore the current sensor parameters. Finally, returning to the Session window, click on the Processor button. This will bring up a new window. By pressing on the Compute button, you will render an image that illustrates how the demosaicd and processed data will appear on a model display.

4/20/2007

ISET

USER

MANUAL

More details about each of these windows and their functionality are described below. You can close any of these windows at any time, without losing the underlying data. Pressing on the Session button for that window will bring the window back up with all of the stored data. At any time, you can save the Session data from the File menu in the Session window. There, you can also save the data and close all of the ISET windows. For programming: The data from the ISET session are stored in a large structured variable called vcSESSION. At present, the data can be extracted from this variable directly from the Matlab workspace. In the future, data will be extracted from this variable using object based routines including of the form, get(scene, parameter). Currently, the files sceneGet, opticsGet, sensorGet, and vcimageGet are used to retrieve Session data as well as compute various important variables from the vcSESSION structure.

4/20/2007

ISET

USER

MANUAL

Using ISET 2.0


The ISET software is organized into four main parts corresponding to four stages in the imaging pipeline. These are the Scene, Optics, Sensor, and Processor. The user creates and manipulates the objects and algorithms that transform the scene into an optical image at the sensor, the optical image into a sensor image, and the sensor image into a set of digital values for display. ISET is open-source. The Programmers Guide includes the ISET Matlab functions associated with the scene, optics, sensor and processor windows. By reading the ISET functions, the user can learn how the data are created and transformed. Users can find examples of ISET Matlab scripts that call these functions in the ISET Directory titled Scripts. In our experience, people begin using the ISET GUI to learn about functions and derive some intuitions about the significance of different parameters. As they begin their own experimental analyses, they begin to write scripts designed to evaluate their processes and ideas. The Scripts directory is a good place to learn about how to write scripts and perform various types of analyses.

Session Window
After installing the software, type iset into the Matlab prompt. A small Session window will appear. This window allows the user to access each of the principal object windows used to create and manipulate data. The four buttons in the window are ordered to follow the imaging pipeline: Data begin in the Scene, pass through the Optics, are captured by the Sensor and transformed by the Processor to yield a final display image. In this introduction we explain the main functions of each of these windows, in turn, and provide some examples of how the software can be applied to analyze the imaging pipeline.

4/20/2007

ISET

USER

MANUAL

Scene
The simulation pipeline in ISET begins with scene data; these are transformed by the imaging optics into the optical image, an irradiance distribution at the image sensor array; the irradiance is transformed into an image sensor array response; and the image sensor array data are processed into an image for display. The scene information is modeled as light from a diffusely reflecting plane at a fixed distance from the imaging lens. Equivalently, you can imagine the scene as a diffusely emitting surface (e.g., a cathode-ray tube display) at that distance. Information about the scene is stored in a SCENE structure. The routines for controlling the information in the SCENE structure are sceneGet and sceneSet. To create a SCENE structure use sceneCreate, a function that contains many scene types used for system evaluation (described below). The headers of these three functions contain documentation about the SCENE structures. The ISET\Scripts\Scene directory contains examples of creating a variety of SCENE structures. ISET is open-source, by reading the code that creates the scene you can see the precise way the scene is generated and answer any questions about the scene properties. The parameters and properties of the SCENE structure can be managed using the sceneWindow graphical user interface (GUI). In this section, we describe the representation of scene information and present examples of scenes that can be created automatically to test the image system properties.

Scene data
You can create a default SCENE structure by starting Matlab, making sure ISET-2.0 is on your path, and then typing SCENE = sceneCreate('macbethD65'); The variable SCENE is a structure containing several slots that describe the scene information. You can see these slots by typing scene into the Matlab prompt.

4/20/2007

ISET

USER

MANUAL

10

SCENE = type: spectrum: name: distance: magnification: data: wAngular: 'scene' [1x1 struct] 'Macbeth (D65)' 1.2000 1 [1x1 struct] 8

The scene data comprise a radiance image. The radiance represents photons emitted from a point in a plane located at the SCENE.distance (specified in meters from the imaging lens). The data slot in the SCENE structure contains a representation of the (diffusely radiating) photon data. The wavelength samples are contained in the SCENE.spectrum slot. The angular width of the image (degrees) is represented in SCENE.wAngular. To retrieve data about the scene, the user should use sceneGet. For example, to extract the photon data from the scene use: photons = sceneGet(SCENE,'photons'); The variable photons is a (row,col,nWavelength) array. The entries of photons have units of photons/sec/nm/ m2/steradian. The scene photons are stored in a compressed format. The data are stored at 16 bits of resolution, but in a floating range because the scene radiance levels can be very large. The compression and decompression are handled using the routines ieCompressData and ieUncompressData. The user should not have to invoke these routines. The sceneGet function incorporates a number of basic operations that are frequently needed. For example, if you would like to retrieve the data in energy units, you can invoke energy = sceneGet(SCENE,'energy'); The variable energy is in units of watts/s/m2/nm/sr, and the conversion from photons is done by the sceneGet function. If you wish to extract only the photons at selected wavelengths, you can add an argument as in photons = sceneGet(SCENE,'photons',[550, 600]);

4/20/2007

ISET

USER

MANUAL

11

In this case the photons variable is (row, col, 2). The sceneGet function, as other get functions in ISET, includes many computations. The software is designed to store a minimal set of basic variables in the structure (e.g. SCENE) and to use the get function (sceneGet) to derive other quantities on-the-fly. Before computing a scene quantity, we recommend that you check the header of sceneGet to see whether that quantity is already computed for you. An advantage of using ISET is that you can verify the specific computation by reading the open-source Matlab code in the sceneGet (or other) functions.

Scene window
The scene window (sceneWindow) offers a graphical means for interacting with the SCENE structure. The window uses the same format as other ISET windows, although it is slightly simpler. ISET windows have the same basic structure as this window. By placing your mouse over either the box or its title, a tooltip will be rendered to offer a slightly longer reminder about the meaning of each edit box.

Figure Scene-1. ISET Scene window: An example of a Gretag/Macbeth Color Checker image used to analyze system color properties.

4/20/2007

ISET

USER

MANUAL

12

The main image represents the SCENE data. Remember that the displayed image is only an RGB representation of the SCENE data; the scene data are spectral. ISET uses a simple rendering algorithm to show the spectral data using an RGB format (sceneShowImage). The gamma curve for the rendering the data in the image is controlled by the Edit box in the lower left. Adjusting this value helps see parts of high dynamic range images; the value in this box does not influence the underlying data. The text box in the upper right corner of the scene window contains a set of variables that are frequently used when performing imaging analyses. These values are derived from other scene parameters; they cannot be set themselves. These values are updated during every refresh (sceneSetEditsAndButtons). Several frequently edited quantities can be changed by the Edit boxes in the lower right. These include the mean scene luminance, the field of view, and the distance of the plane from the imaging lens. You might try adjusting, say, the FOV to see the consequences on the horizontal resolution (H-Res). The first two pull down menus are sceneWindow | File and sceneWindow | Edit. These menus include various routines that manage saving, loading, renaming and other basic properties. The sceneWindow | Plot pull down provides various summary plots of the current SCENE structure. The sceneWindow | Scene pull down creates and edits SCENE properties. The sceneWindow | Analyze pull down provides some basic tools to analyze the data within the current scene. In future releases of ISET, the sceneWindow | Help function will bring the user to manual pages, such as this, describing ISET functions.

Scene creation
The sceneCreate function creates many types of scenes that we summarize in four categories. These are scenes designed to clarify system (a) color properties, (b) spatial resolution, (c) noise, and (d) general image quality. Examples from each category also can be created from the sceneWindow | Scene pull down menu. We describe each of these in turn.

1. Color test patterns


You can create various color images based on the Gretag-Macbeth Color Checker. These images combine the spectral reflectance properties of the target

4/20/2007

ISET

USER

MANUAL

13

with a variety of standard illuminants to create a radiance image. The key function within sceneCreate that creates Macbeth images is sceneCreateMacbeth. It is possible to modify these images to simulate different illumination functions. See the relevant code called by sceneWindow | Edit | Adjust SPD. With that pull down, you can select a file containing illuminant information, divide the radiance image, and then multiply by a new illumination function. Future plans include creating simulated images based on the much larger sample of reflectance data from ISET-2.0 database.

2. Spatial test patterns


The Color Checker is made from relative large patches. To examine the spatial resolution of the image system ISET-2.0 includes a variety of spatial patterns. These can be found in the pull down sceneWindow Scene | Patterns. From the pull down menu, you can create a Mackay pattern, as illustrated in the image below. You can also create pattern containing multiple spatial frequencies at a variety of orientations (Freq-Orientation), a grid pattern or dot pattern (useful for geometric distortion), a slanted line used for the ISO-12233 standard, and many others.

Figure Scene-2. pattern

ISET Scene:

Mackay test

One easy way to adjust the spatial sampling density of these patterns is to vary the field of view (FOV). When you create these patterns using the sceneCreate function directly, you can set the parameters as arguments to this function. For example, to create an array of points, you can specify the size of the image (in pixels) and the number of pixels between the points using the call

scene = sceneCreate('pointarray',imageSize,pixelsBetweenPoints);

4/20/2007

ISET

USER

MANUAL

14

Each of the different scene types has its own associated calling arguments. These are described in the header to the sceneCreate function.

3. Sensitivity and noise evaluation patterns


It is often useful to evaluate the system sensitivity and noise using very simple targets. A set of intensity ramps running from average intensity at the bottom of the image in either decreasing intensity (left side) or increasing (right side).

Figure Scene-3. ISET Scene: An image ramp useful for testing noise properties and sensitivity.

4. High Dynamic Range Multispectral Scene Data


The ISET package includes two images from ImagEvals high dynamic range spectral (HDRS) image database. These multispectral scene data can be loaded using the pull down sceneWindow | Scene | Choose File | Multispectral. One of these images is shown in Figure Scene-4. These HDRS images also include information about the scene illuminant. The illuminant SPD can be plotted using sceneWindow | Plot | Illuminant SPD. This makes it possible to re-illuminate the image computationally by dividing the scene data by the illuminant and then multiplying by a new illuminant function (see sceneWindow | Edit | Adjust SPD).

4/20/2007

ISET

USER

MANUAL

15

Figure Scene-4. ISET Scene: An example of a scene from from our high dynamic range spectral (HDRS) image database.

These images are obtained using a calibrated camera and multiple images of the same scene. By using images with different exposure durations as well as images measured through a variety of color filters, we obtain high-dynamic range spectral approximations of the light radiance field. Appendix A describes in more detail about how these HDRS images are created. Currently, the database contains 25 scenes, each measured at three spatial resolutions (253 x 380, 338 x 506, and 506 x 759). We are in the process of expanding the number of images and increasing their resolution.

5. RGB Images
It is possible to load RGB and monochrome images as scene data. ISET will read any image files supported by the Matlab imread() function; the full list can be specified by calling the Matlab imformats() function. RGB and monochrome image data do not contain a full representation of the scene SPD. To create scene data from such images, we build a representation of the spectral radiance that would be emitted when the image is displayed on a monitor with non-overlapping primaries in the red, green and blue bands. Under these conditions, the spectral radiance data is not an accurate representation of the scene spectral power distribution. Using this method, however, we can use ISET to examine many complex and interesting types of images and patterns.

4/20/2007

ISET

USER

MANUAL

16

Computational methods
The scene data are used to initiate the computations in the imaging pipeline. They are used as one of the two structures input to the oiCompute function, which combines scene and optical image information to calculate the irradiance at the image sensor array surface. The functions Quanta2Energy and Energy2Quanta convert scene radiance data units. The sceneWindow | Analyze pull down includes several functions that compute luminance (candelas per meter-squared) and chromaticity coordinates (CIE, 1931) from the scene radiance data.

Scene Image Size


We find that people initially like to perform calculations using large images. With experience, however, we find that such images are rarely useful in engineering applications. The number of spatial samples needed for the scene depends on the field of view. If you analyze a scene that has a very large field of view (40 deg), then you may in fact need a very large scene image. But for most purposes engineers find it satisfactory to understand the representation over a much smaller field of view, say the central 5 or 10 deg. In this case, there is not usually a need to represent the scene with 1K x 1K samples. Consider this example. Suppose we are studying the properties of an imaging system with a diffraction limited lens with F# = 2.0. The blur circle of such an ideal lens is a 2-3 um. Hence, the scene does not need to be represented at a resolution finer than 1.0 um resolution. For a region of the image that is 5 deg, this can be achieved using a 200x200 scene. If we go to higher F#s, or lenses that with performance that is worse than diffraction limit, or we use an optical diffuser, then even the 200 x 200 number is more than we need. The reason one might want a very large image is only if you wish to simulate an image in which you have a space-varying model of the lens and you would like

4/20/2007

ISET

USER

MANUAL

17

to simulate the entire image over, say, a 40 deg field of view. Then you would need to represent the input image at adequate sampling resolution over the entire 40 deg field of view. We do have customers who do this. They manage the large data set, however, by scripts and several simple tricks for minimizing the memory requirements. This application, however, is unusual rather than common. Even in this case, it is possible to explore the different parts of the scene by adjusting the optics to represent the central portion or edge portion of the image and making separate calculations. If you only want to explore image processing calculations on real camera images, then you can load the raw sensor camera data into the Sensor window. In that case, because the data are only RGB and not wavelength sampled, it is possible to work with much larger image sizes.

Analyze, Plot and Graphs


To help understand systems, we frequently use many of the graphing and data analysis functions in the optics window. We suggest that you explore the plots and analyses within the sceneWindow | Plot and sceneWindow | Analyze pulldown menus. You can use the tools in this menu to plot the sensor irradiance data and measure its color properties.

4/20/2007

ISET

USER

MANUAL

18

Optics
The simulation pipeline in ISET begins with scene data; these are transformed by the imaging optics into the optical image, an irradiance distribution at the image sensor array; the irradiance is transformed into an image sensor array response; and the image sensor array data are processed into an image for display. The optical image describes the irradiance prior to interactions with the integrated sensor, but after passage through the imaging lens. The optical image is still light and represented in the form of photons (or energy) as a function of wavelength. Information about the optical image is stored in an optical image (OI) structure. The routines for controlling the information in OI structure are oiGet and oiSet. To create a default OI structure use oiCreate. The headers of these functions contain a great deal of documentation about the OI structures. The ISET\Scripts\Optics directory contains examples of creating and calculating with OI structures. The parameters and properties of the OI structure can be managed using the oiWindow graphical user interface (GUI). The most important OI structure slots are data and optics. The data slot is straightforward. Much of this document describes the representation of optics information and the three computational models for the optics.

Optical image data


The data representation is straightforward. The data are stored in the OI structure (OI.data). The data are a compressed representation of the irradiance image. This information should only be read or stored using the oiSet and oiGet routines. These routines handle the compression and decompression correctly using the routines ieCompressData and ieUncompressData.

Optics Models
The main portion of ISET uses two principle image formation computations. These are based on a diffraction-limited optics model and a general shiftinvariant optics model.

4/20/2007

ISET

USER

MANUAL

19

In addition, ISET supports an extra imaging module that is capable of simulating a full ray trace calculation using a lens description derived from Zemax or Code V. This is a separate add-on module that is not part of the basic ISET description. In this manual, we describe the diffraction-limited and shiftinvariant methods in detail. We provide only a short description of the ray trace optics model, which is described in more detail in the Appendix. In the next sections we describe the interface to these optics calculations through the oiWindow GUI. When the window is opened, you can mouse-over many of the entries to get a reminder or fuller description of their meaning. You can perform all of the operations described in the GUI from the Matlab command interface. There are many examples of how to do this in the ISET\Scripts directory. You can see the precise calculations used for these functions because all of the computational code is freely readable. This is an important advantage of ISET over many computational tools.

1. Diffraction-limited optics
The basic and default imaging modality assumes that the imaging lens is diffraction limited and passes all wavelengths fully. We further assume that the relative irradiance of the lens follows the cos4th fall-off, as is commonly described in the optics literature. Finally, in this optics mode we allow the user to simulate a small diffusing material in the optical path (e.g. anti-aliasing filter) that introduces a Gaussian blur into the irradiance image. The Optics window can store several different optical images. You can change between them using the pull-down menu above the image. Pull-down menu items are also available for naming and editing the optical images. The optics model is selected using the pull-down menu on the right. Just above the pull-down menu is a textbox that contains a variety of useful parameters about the optical imaging, including the number of spatial samples, the wavelength samples, the height and width of the image, and so forth. These data can all be obtained at the Matlab prompt from the optical image using the oiGet command.

4/20/2007

ISET

USER

MANUAL

20

Figure Optics-1. ISET Optical Image: Diffraction-limited optics model

In the diffraction-limited model, the f-number and focal length are set using the edit boxes below the pull-down. You can also make some choices about the computational stream. First, you decide whether to include relative illumination by clicking on the button Off axis (cos4th). This is implemented in the function cos4th. You also decide whether to include a wavelength-independent Diffuser. Optical diffusing materials are also called anti-aliasing filters and they are often superimposed on the surface of image sensors. There are a variety of complex types; but for this simulation we include only the Gaussian blur. The full-width half-maximum spread of the Gaussian diffuser is specified in the edit box (units are microns). This blurring is implemented in the function oiDiffuser. Once the parameters are adjusted, you initiate the computation of the optical image using the large button at the bottom of the Optics window (Compute Optical Image). This button makes a call to the oiCompute routine that integrates information from the scene and OI structure to produce the irradiance image.

4/20/2007

ISET

USER

MANUAL

21

The large red spot adjacent to the Compute Optical Image button is turned on when there is a chance that the parameters of the optical image may have been changed since the last computation. The red mark disappears immediately after a computation. It is turned back on following most parameter edits. Finally, the Gamma button at the left adjust the rendering of the data onto the display. It does not affect the data stored in the OI structure.

2. Shift-invariant optics calculations


The transformation from the scene data to the sensor irradiance is managed by a convolution applied separately to each waveband. This is a good approximation for the central part of most imaging lenses. The central part is sometimes called paraxial imaging. Diffraction-limited imaging uses a specific convolution kernel that defines the optimal transformation from scene to sensor irradiance (see dlMTF). But real lenses rarely achieve optimal performance at all wavelengths, even within the central (paraxial) portion of the image. The convolution kernel (i.e., the point spread function) of a real lens is broader than the convolution kernel for a diffraction-limited system. Using ISET-2.0 you can design and use your own wavelength-dependent point spread functions. The information you need to create such functions and use them with ISET-2.0 is described in the script s_IExamples.m. (In ISET all scripts begin with s_, s underscore). You can load the saved the shift-invariant point spread function information into the Optics window using the pull-down menu (Optics | Load SI Data). If you do not have any data of your own, but you would like to see examples, you can select Optics Import Optics from the ISET-data\optics directory. Two example optics files are siPillBox.mat and siGaussian3to1.mat. You can load the saved data for the pillbox directly using Optics | Load SI data and choosing the file siPillBox-data.mat.

4/20/2007

ISET

USER

MANUAL

22

Figure Optics-2. ISET Optical Image: Shift-invariant optics model

Whether you are using the shift-invariant optics or the diffraction-limited optics, other options are the same. Diffraction-limited calculations are essentially the same as shift-invariant apart from the special point spread function characteristics of the diffraction-limited operation.

3. Ray trace optics


If we wish to simulate a larger portion of an image, then it is necessary to model changes in the point spread function across the imaging surface. The distance from the center of the image to the margins is usually called the field height. A complete model of the effect of the imaging optics needs to account for the geometric distortions introduced by the lens and the fact that the point spread function varies with the field height and field angle. Managing this much larger simulation is significantly more complicated than a convolution operation. For most applications, it is sufficient to use a point spread function that captures a locally shift-invariant region of the image. (In optics, such a region is called isoplanatic).

4/20/2007

ISET

USER

MANUAL

23

ImagEval offers a toolbox for integrating ray traced lenses with the optics window. The approach we take is to use ray trace programs, such as Code V and Zemax, to calculate a set of files based on the lens descriptions. These files describe relative illumination, geometric distortion, and point spread functions as a function of field height. We read in these files, store this information in the optics structure and use it to compute a more precise irradiance image. For more information about this toolbox, contact us at ImagEval.

Computational methods
The optical image computation is first managed by oiCompute. This routine determines the optics model and distributes the computations to opticsDLCompute, opticsSICompute or opticsRayTrace. Reading these three routines provides a detailed analysis of the computation. Other important routines called within opticsDLCompute and opticsSICompute are opticsOTF, opticsCos4th, and oiDiffuser. The opticsRayTrace routines are significantly more complex. The computational approach is to store the optical transfer function (OTF) in the optics structure. We perform the convolution of the image waveband by waveband in the Transform domain. Image and OTF management for this convolution, as well as for transforms from OTF to point spread function, is described in s_FFTinMatlab and in the opticsGet routine.

Analyze, Plot and Graphs


To help understand systems, we frequently use many of the graphing and data analysis functions in the optics window. We suggest that you explore the plots and analyses within the oiWindow | Analyze pull-down menu. Using these functions you can visually inspect the point spread function at different wavelengths, or the line spread function at different wavelengths, and many related optics properties. You can also use the tools in this menu to plot the sensor irradiance data and measure its color properties.

4/20/2007

ISET

USER

MANUAL

24

4/20/2007

ISET

USER

MANUAL

25

Sensor
The ISET simulation pipeline begins with scene data; these are transformed by the imaging optics into the optical image, an irradiance distribution at the image sensor array; the irradiance is transformed into an image sensor array response; finally, the image sensor array data are processed to generate a display image. ISET image sensors are modeled as an array of pixel. Each pixel includes a microlens, color filters, a tunnel of some depth corresponding to the sensor metal layers, and a photodetector. A large number of optical and electrical properties can be modeled, including the spectral characteristics of the filters, indices of refraction of the metal layers, electrical noise in the detectors, array inhomogeneities, and so forth. Sensor information is stored in an Image Sensor Array (ISA or SENSOR) structure. We create a SENSOR structure using sensorCreate. The SENSOR structure properties are managed using sensorGet and sensorSet. The headers of these three functions document the SENSOR parameters. The ISET\Scripts\Sensor directory contains examples of creating a variety of SENSOR structures. ISET models the sensor array as comprising one type of pixel that is repeated across the array. The pixel information is represented in a PIXEL structure that is part of the SENSOR structure. The PIXEL structure is created using the function pixelCreate; the functions pixelGet and pixelSet manage the pixel properties. Variations in the pixel properties across the array are managed by sensor{Set,Get}. The parameters and properties of the SENSOR and PIXEL structures can be managed using the sensorImageWindow graphical user interface (GUI). ISET is open-source. You can always read the code that creates the SENSOR or PIXEL to see the precise way these structures are stored or computed. This section describes the representation of sensor and pixel to test the image system properties.

4/20/2007

ISET

USER

MANUAL

26

Sensor window
The sensor window (sensorImageWindow) is a graphical means for interacting with the SENSOR structure and setting the sensor computation parameters. The SENSOR window uses the same format as other ISET windows; because the SENSOR and PIXEL structures are complex this is a fairly complicated window, When you place the mouse over an editable box or its title, a tooltip appears that briefly describes the parameter or computation.

Main image

Figure Sensor-1. ISET Sensor window: An example of a Gretag/Macbeth Color Checker image acquired with a conventional Bayer (GRBG) sensor.

The main image represents the SENSOR data before it has been processed. Depending on how you have set the processing parameters, the sensor data are analog voltages, electrons, or digital values. The sensor data are not yet demosaicd, color balanced, and so forth. This processing takes place in the image processing window, described in the next section.

The SENSOR data are rendered using a simple algorithm that provides some guidance about the type of pixel at each location. Each pixel is displayed using a color based on the spectral transmissivity of the color filter for that pixel. The pixel intensity is measures the pixel response level as a proportion of the maximum possible level. Thus a pixel with a red filter and a response near the saturation voltage will be rendered as bright red. This algorithm is implemented in the function sensorData2Image.

4/20/2007

ISET

USER

MANUAL

27

There are multiple ways to examine the pixel values in an image region. You can examine the data visually by zooming into the window with the pulldown menu Edit | Zoom. This turns on zoom within the main image. When your mouse is over the image, you will see the magnifying icon and you can zoom into the image by clicking. To zoom out, use shift click. You can also explore the data in detail using the Edit | Viewer menu. This will display the data using the Matlab imtool function. You can use the Matlab interactive imtool to explore individual values in more detail. Finally, there are multiple ways to plot the sensor data within the Analyze and Plot pulldown menus. These include functions that plot the number of captured electrons along a line (Analyze | Line) or within a region of interest (Analyze | ROI). For example, the image in Figure Sensor-2 shows the number of electrons captured in the green and blue pixels of the image at line #116, which runs through the gray series. Notice that the axes are specified in physical units (position along the sensor array) and number of electrons captured. Whenever possible, ISET-2.0 uses physical units to describe sensor responses or properties. Most ISET plot windows contain user data so that the user can retrieve the plotted data. For example, after producing the graph at the left using the Plot | Line pulldown call, you can retrieve the position and electron values using >> get(gcf,'userdata') ans = pos: [176x2 double] data: [88x2 double]

4/20/2007

ISET

USER

MANUAL

28

Figure Sensor-2. An example of plotting the sensor values along a line, using the Analyze | Line | Horizontal pulldown menu. This line shows the electrons at pixels in the middle of the gray series at the bottom of the Gretag/Macbeth color checker. Data can be graphed using a variety of pulldown options from the Plot and Analyze menus.

The appearance of the sensor data in the main window is controlled using the two controls in the lower left part of the Sensor Window. The gamma curve parameter determines how the sensor data levels are mapped in the digital display images. Adjust this value to a fraction, say 0.3, to visualize high dynamic range sensor images. The scale button renders the data so that the brightest sensor data is at the peak display intensity. This parameter and button do not influence the data only how the data are rendered to your screen.

PIXEL descriptions
The left side of the SENSOR Window describes and controls several PIXEL parameters. The edit boxes on the left control four basic PIXEL parameters. These are the dark voltage, read noise, conversion gain, and voltage swing. The user can control many other pixel parameters by the using items in the pulldown menus Edit and Sensor. The text box on the upper left contains a set of other important PIXEL variables, including the pixel and photodetector size, the percentage of the pixel filled by the photodetector, the well capacity (in electrons) the pixel dynamic range for a

4/20/2007

ISET

USER

MANUAL

29

1 ms exposure, and the pixel signal-to-noise (SNR) ratio in decibels. The geometric properties of the pixel and photodetector are set by the pulldown Sensor | Design Photodetector geometry. Several of these quantities, such as the Well capacity, are derived from other pixel properties and cannot be set themselves. The pixel values are updated during every refresh (sensorEditsAndButtons).

SENSOR descriptions
The right side of the SENSOR Window describes several SENSOR parameters and contains several items that set properties of the computation.

Setting and controlling SENSOR parameters and data


You can create a default SENSOR structure by starting Matlab, making sure ISET-2.0 is on your path, and then typing SENSOR = sensorCreate; The variable SENSOR is a structure containing many slots that describe the sensor information. You can see these slots by typing SENSOR into the Matlab prompt. SENSOR = name: 'bayer-0' type: 'ISA' pixel: [1x1 struct] rows: 72 cols: 88 spectrum: [1x1 struct] data: [] sigmaGainFPN: 0 gainFPNimage: [] sigmaOffsetFPN: 0 offsetFPNimage: [] integrationTime: 0 AE: 0 CDS: 0 quantization: [1x1 struct] cfa: [1x1 struct] color: [1x1 struct]

4/20/2007

ISET

USER

MANUAL

30

The slots at the lowest level of the SENSOR structure are either (a) parameters that apply to the entire sensor array, or (b) several key structures. These parameters and structures are described in the sensor{Get,Set} comments and summarized below. SENSOR parameters The name and type fields are straightforward; the type is always ISA so that routines can identify the structure. The name can be adjusted using SENSOR = sensorSet(SENSOR,name,mySensorName); The pixel slot is a large structure that contains many parameters characterizing the pixel size, electrical and optical properties. We describe this structure in a separate section below. The pixel is important enough that it has its own management routines, pixelGet/Set. The rows and cols slots define the SENSOR array size. The spectrum slot is the same structure that is contained in the scene and optical image structures. The spectrum structure lists the wavelength samples used in computing the sensor response. ISET-2.0 checks the spectral representation in the SENSOR with that in the Optical Image an interpolates the two types of data to estimate the SENSOR response. The data slot stores computed values such as the analog voltages at the pixel photodetectors or the digital values corresponding to each pixel. The data values stored depend on the computation, such as the level of quantization established in the quantization structure (see below). The parameters that follow are related to the sensor noise properties and the way the pixel response function is computed. The pixel response maps the light incident at the pixel, E ( ) , into a voltage response, vi . If a detector has spectral quantum efficiency S ( ) , then the ith pixel voltage is calculated using the formula

vi

gi

E ( ) S ( )d

oi

The parameters gi and oi are the gain and offset for the ith pixel.

4/20/2007

ISET

USER

MANUAL

31

ISET models the gain and offset as Gaussian random variables across the image sensor array. The sigmaGainFPN and sigmaOffsetFPN slots store the standard deviation of these two parameters. In some cases we wish to keep an instance of these parameters, so we store an entire array of the gain and offset values in the gainFPNimage and offsetFPNimage fields. The AE (auto-exposure) slot is a binary flag that determines whether the autoexposure algorithm is used. The integrationTime parameter determines the integration time when auto-exposure is false (sec), or stores the actual exposure time set by the auto-exposure routine. The CDS (correlated double-sampling) slot is a binary flag that turns on or off correlated double-sampling in the computation. CDS is a method for reducing fixed noise. The method works by acquiring two frames nearby in time and storing only the difference. Different companies implement correlated double sampling in a variety of ways; the ISET simulation acquires a frame with integration time 0 and then at the full exposure time. The difference between these two is stored. This has the consequence of removing the offset error. The quantization slot determines whether we compute digital (linearly quantized) or analog photodetector voltages or not. SENSOR.quantization = bits: [] method: 'analog' If the quantization flag is on, the number of quantization bits is also stored in this structure. The method slot should be either analog or linear. The number of bits is typically 8,10 or so forth, referring to linear quantization at 2^bits levels. In the future, we will implement square-root and other custom quantization schemes. The cfa (color filter array) contains information about the spatial structure of the color filter array. The cfa field is a matrix that indicates the position of the color filters within the array. For example, suppose that the color filters are of RGB type, stored in that order. If you are coding a Bayer color filter array pattern, then the entries with [G R; B G] structure, then the pattern field will be SENSOR.cfa.pattern ans = 2 1 3 2

4/20/2007

ISET

USER

MANUAL

32

The color structure describes the spectral transmission of the color filters. The color structure contains SENSOR.color ans = filterSpectra: [31x3 double] filterNames: {'rDefault' 'gDefault' irFilter: [31x1 double] 'bDefault'}

The filter transmissivities are stored in the columns of the filterSpectra slot; brief names are stored in the filterNames slot, and the irFilter transmissivity is stored in the irFilter slot. If you purchased the microlens toolbox, then the SENSOR structure may contain two additional fields: etendue and ml. These store properties concerning the optical transmission associated with the microlens properties. Finally, after you use the SENSOR in a computation, a consistency field will be added that stores whether any of the SENSOR parameters have been touched since the last computation of the SENSOR data.

Setting and controlling PIXEL parameters and data Computational methods

4/20/2007

ISET

USER

MANUAL

33

Processor
The ISET simulation pipeline begins with scene data; these are transformed by the imaging optics into the optical image, an irradiance distribution at the image sensor array; the irradiance is transformed into an image sensor array response; and the image sensor array data are processed to become a display image. This final portion of the simulation is called the image-processing pipeline. In this stage, the image sensor data are converted into RGB display data. ISET includes several algorithms needed for basic camera operation: exposure duration (auto-exposure), faulty pixel replacement, interpolating missing RGB sensor values (demosaicing), and transforming the sensor color data using methods that account for both the sensor spectral characteristics (color conversion) and the illumination conditions (color-balancing). The ISET-Processor window is a graphical means for computing and interacting with the processed data. The processed data are stored in a virtual camera image (VCI) structure. This structure is initiated using the vcImageCreate command. >> vci = vcImageCreate vci = name: type: spectrum: data: display: demosaic: colorbalance: colorconversion: internalCS: 'vcimage' 'vcimage' [1x1 struct] [1x1 struct] [1x1 struct] [1x1 struct] [1x1 struct] [1x1 struct] 'sensor'

The VCI structure fields are read or set using the imageGet and imageSet commands. The function headers contain a great deal of documentation about the VCI structure and quantities that are derived from its parameters. The ISET\Scripts\Processor directory contains scripts that illustrate how to creating and calculate with VCI structures. The user can adjust the VCI structure properties and experiment with several types of computations from the ISET-Processor window. The window is shown in Figure Processor-1.

4/20/2007

ISET

USER

MANUAL

34

Figure Processor-1. ISET-Processor window for experimenting with the imaging pipeline.

The image processing pipeline begins with the data in the sensor. The first step in the pipeline is to interpolate the sensor color filter array mosaic into a full representation. The demosaic algorithm can be selected from a standard set by the first pull-down menu option to the right of the main image. The second step is to convert the sensor data into an RGB format. This color conversion step is controlled by the second and third pull-down menus. The options for conversion include specification of the Color Transform algorithm and a specification of the internal color space for applying the algorithm. The color conversion algorithms use a model display for as a target. By default, the image processing pipeline assumes that the sensor data are rendered on a display with standard (sRGB) color primaries. It is possible for the user to set a different target display in the interface (Processor | Display | Adjust Display Properties) or by using Matlab commands.

4/20/2007

ISET

USER

MANUAL

35

Color-balancing is the final stage of the pipeline. Again, there are several simple algorithms included in this pull-down menu. The Processor window includes several image quality metrics to help the user quantify color fidelity and image sharpness. There are specific algorithms for evaluating color fidelity and spatial sharpness. These algorithms can be accessed from the ISET-Processor | Analyze pull-down menu. The set of algorithms for demosaicing, color-conversion, and color-balancing and metric calculations are discussed and explained in more detail in the sections below. Several examples of these applications are also provided therein. The simulators extensible and open-source architecture enables the user to insert proprietary image-processing algorithms in the pipeline and to evaluate how different algorithms perform under various imaging conditions. In the following sections we describe some of the basic image processing algorithms and image quality metrics.

Auto-exposure
The auto-exposure algorithm is an important part of the image processing pipeline. A good choice for the exposure duration makes an enormous difference in the final image quality. Unlike all of the other processing algorithms, the auto-exposure algorithm is not part of the ISET-Processor window. The exposure duration algorithm is run during the ISET-Sensor calculations. prior to the SENSOR structure. The ISET routine sensorSet is used to control the exposure duration. The routine can either set an explicit exposure duration (units are seconds). For example, to set a 100 ms exposure use the sensor parameter integrationTime, as in sensor = sensorSet(sensor,'integrationTime',0.1); Alternatively the sensor parameter autoexposure can be set to use an autoexposure algorithm, as in sensor = sensorSet(sensor,'autoexposure',1); ISET includes a general interface routine that specifies which algorithm should be used to determine the exposure value. The default auto-exposure algorithm is described in autoExposure. The Appendix includes a description of the default auto-exposure algorithm, which is based on the signal luminance at the brightest location within the image.

4/20/2007

ISET

USER

MANUAL

36

exposureTime = autoExposure(OI,SENSOR,Level);

Demosaicing
Each pixel in the sensor image is a red, green OR blue sensor. To create a display image, we interpolate the missing data so that the display image has a red, green AND blue pixel value at each location. Methods for interpolating the missing data values are referred to as demosaicing. ISET includes four demosaicing algorithms: Nearest Neighbor, Bilinear, Laplacian, and Adaptive Laplacian. When using the ISET-Processor window, you can select which algorithm is used from the pull-down at the right side of the image. Differences between demosaic algorithms can be quite significant. The images below compare the results of using Bilinear and Laplacian algorithms. The test pattern is designed to highlight demosaicing artifacts. The pattern includes monochrome gratings that differ in both spatial frequency and orientation. Demosaicing artifacts are visible as color aliasing. The pattern can be loaded in the Scene Window by selecting Scene | Patterns | Freq-Orientation or in the Matlab command window by using the ISET routine called sceneCreate

Figure Processor-2. Comparison of Bilinear (left) and Laplacian (right) demosaicing algorithms applied to a sensor image of a simple frequency-orientation test target.

To select a demosaicing algorithm from within an ISET script, you can use a command such as vci = imageSet(vci,'demosaicmethod','adaptive laplacian');

4/20/2007

ISET

USER

MANUAL

37

You can set the demosaicing method to the standard Matlab sub-routines provided in ISET, or to a custom Matlab demosaicing algorithm that you provide. The arguments for the custom demosaic routine should be demosaicedImage = myDemosaic(imgRGB,SENSOR); In this case imgRGB is an RxCxW image representing the row (R) by col (C) SENSOR data from W-color filter types. Data in the individual planes are mainly zero. The demosaic algorithm interpolates the data to return a full RGB (RxCx3) image that can be displayed. Please read the code in the routine Demosaic.m to see the general calling convention. Helpful routines for designing demosaic algorithms are located in the directory \ISET-2.0\imgproc\Demosaic.

Color rendering
In a wonderful world, we could copy the sensor RGB values into the RGB values of a display controller and render an accurate image. While the world we live in is wonderful in many respects, this is not one of them. Copying sensor RGB directly to display RGB will not produce a high quality output. There are many algorithms to transform sensor RGB data into display RGB. We refer to the entire process of transforming sensor color data to display data as Color rendering. Many (but certainly not all) color rendering algorithms can be divided into three parts. The literature is inconsistent in naming the three stages of this process. We are consistent; we apologize if we are not consistent with the usage you have learned. First the sensor data are transformed into a calibrated color space. We call this stage Color conversion. Second, the data are processed within this space to enhance contrast and improve appearance. We call this, Color processing. This stage includes algorithms such as color balancing, as well as contrast or brightness enhancement. Third the image data are converted into a display space. We call this Display rendering. This stage includes algorithms such as gamut-mapping (accounting for the fact that the display has a limited gamut). There are many possible color conversion algorithms; we implement two types of one basic (3x3 matrix) approach through the ISET-Processor window. In the next section, we describe the ISET color rendering process that can be controlled from

4/20/2007

ISET

USER

MANUAL

38

the ISET-Processor window. It is also possible to substitute your own custom color rendering process using ISET scripts.

Color conversion
First, we describe a means of identifying a color conversion matrix that is based on a calibrated target, the Macbeth Color Checker illuminated under a particular illumination (D65). This method is used when you select MCC Optimized under the Color transform method. Second, we describe a method of entering a color conversion matrix manually. You can do this by choosing the option Manual Matrix Entry.
MCC Optimized. Because the MCC target and D65 illumination produce a calibrated

signal, we can calculate the targets effect on the human visual system; say by calculating the CIE XYZ values for the 24 patches in this target. Lets call the 24x3 matrix of XYZ values for this target, tXYZ. Next, we can use ISET to simulate the sensor responses to this same target. Call the 24x3 matrix of simulated sensor responses to this target simRGB. We can compute a color conversion matrix by finding the 3x3 matrix, M, that is the least-square solution to the equation tXYZ = simRGB*M. ISET stores this color conversion matrix and uses it to transform the simulated RGB values into a calibrated color space (in this case the CIE XYZ). It is possible to perform this same calculation in a variety of ways. For example, we may decide to transform the data into another calibrated space (e.g., the Stockman human cone fundamentals). Or we might decide to simply leave the color data in the original sensor space (in which case M is the identity matrix).
Manual Matrix Entry. You may decide to implement a different method for finding

the color matrix. For example, you may not want to use the surfaces in the Macbeth Color Checker to determine the conversion matrix because these surfaces were not designed for this process. Instead, you might use a method like the one above to derive a different 3x3 matrix, M. In that case, you can simply enter the matrix you designed into the processor window by using the Manual Matrix Entry option. When you choose this option, the Internal color space pull down and the Color Balancing pull down are removed. We assume that the matrix you are entering is precisely the one you wish to use to convert from the sensor values to the display result.

4/20/2007

ISET

USER

MANUAL

39

Color processing
There is a limitless set of possibilities for processing enhancing the color data. Smoothing, sharpening, contrast and saturation enhancement, and brightening are all possible to include in this stage of the processing. This broad array of processing algorithms is far too complex to explore effectively within this simulation pipeline. The ISET-Processor window does offer help, however, with one type of color processing: Color balancing. The goal of color balancing is to transform the image data so that the displayed image appears similar to the original image. Because the illuminant in the original image and the implicit illuminant on the display may differ, simply reproducing the same XYZ values on the display will not produce the same color appearance. If you wish to make the rendered image appear similar to the original, when the rendered and original are viewed in different contexts, you must transform the XYZ data to compensate for the illumination difference. The literature on color balancing is quite large and includes many different types of algorithms, of varying complexity. ISET 2.0 includes several popular methods for color balancing. It includes the Gray World algorithm which scales the image R, G and B pixel values so that the mean R, mean G, and mean B values are equal. This method can be applied directly to the linear sensor values (in which case the user selects the Sensor option in the choice of color space), the XYZ transformed pixels values (select XYZ), or the Stockman transformed pixel values. You can, of course, add other color space transformations. ISET also includes a variant of the Gray World algorithm (which we call the White World) which scales the image R, G and B pixels values so that the highest R, G and B values are equal. Again, you select the color space in which the scaling occurs.

Image Quality Metrics


There is no single way to evaluate the quality of an image. The image may have good contrast, but poor color balance. It may be in sharp focus but too dark. Some portion of the image may look great; another may have motion blur. Hence, there can be no single measure of image quality. The ISET-Processor window includes a variety of tools to assess image quality. These can be invoked from the ISET-Processor | Analyze pull-down window.

4/20/2007

ISET

USER

MANUAL

40

In this section, we define the basic image quality measures, and we emphasize those that have a basis in international standards.

Spatial resolution and the MTF


The International Standards Organization (ISO) has adopted a standard (ISO 12233) to evaluate the sharpness of a digital imaging system. The idea is based on measuring the contrast along the edge of a slanted bar target. You can perform this analysis entirely from the ISET-Processor window by first selecting ISET-Processor | Analyze | Create Slanted Bar. This will produce an image of the slanted bar target using the current settings in the optics, sensor and processor window. Figure Processor-3 is an example of a slanted bar image.

Figure Processor-3. A slanted bar image created using the ISETProcessor | Analyze | Create Slanted Bar pull-down menu. When using this pull-down, the system uses the current optics and sensor settings. Alternatively, you can create a slanted bar image explicitly, beginning in the scene window and experimenting with optics, sensor and image

4/20/2007

ISET

USER

MANUAL

41

processing settings.

The ISO 12233 standard then has the user select a region from the edge of the bar. Using the slope across the edge points, the standard computes the spatial modulation transfer function in each of the color channels and for a luminance channel made by adding together the color channels. You can invoke this metric by selecting Image-Processor | Analyze | ISO 12233 (Slanted Bar). After you invoke this command, you choose the rectangular region. An ISET graph window, defining the MTF responses to the different color channels, will be produced.
ISO 12233 1 0.9
Nyquist = 178.57 Mtf50 = 122.56 Percent alias = 27.77

Contrast reduction (SFR)

0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 50 100 150 200 250 Spatial frequency (cy/mm) 300

350

400

Figure Processor-4. The output of an ISO 12233 analysis for particular sensor and image processing configuration. The graph shows the contrast reduction as a function of spatial frequency for each of the three channels, as well as for a luminance channel (black line). In this particular processing configuration, the green and blue channels (but not the red) were scaled by the color balancing algorithm. The demosaicing algorithm was the Laplacian. The optics and pixel size were poorly chosen, so that there is considerable spatial aliasing. The small vertical line (at 178.57 cycles/mm)indicates the Nyquist sampling frequency.

A more detailed description of the metric process is provided in the ISET Application Notes How to Calculate the System MTF.

MCC Luminance noise


The visibility of luminance noise can have a big effect on perceived image quality. The pull-down menu ISET-Processor | Analyze | Color and Luminance | MCC Luminance noise measures the system luminance noise in a Macbeth Color Checker (MCC).

4/20/2007

ISET

USER

MANUAL

42

To perform this analysis, you should create a Scene containing an MCC. Once you have set up the optics, sensor and processing parameters, you can invoke ISET-Processor | Analyze | Compute from Scene to generate a display of the MCC. Next, select the MCC Luminance noise pull-down menu. You will be asked to identify the four corners of the MCC target by left-clicking on the outer corners of the white, black, blue/cyan and brown targets. (You can use the backspace key to undo a point). Click the right button when you are satisfied with the points. (Make sure you clicked in the proper order, as indicated in the text message of the window). This algorithm identifies the central position of the gray-scale sequence at the bottom of the MCC. The percent luminance variance in each of the patches is calculated and plotted in an ISET graph window.
Percent luminance noise (std(Y)/mean(Y))x100
6

1.5

2.5

3 3.5 4 Gray patch (white to black)

4.5

5.5

Figure Processor-5. The percent luminance noise in the six patches of the MCC gray-series. In this case, there is very little noise in the white patch, and nearly 6 percent luminance variance in the black patch. The horizontal line, drawn at 3 percent, marks the visibility threshold for luminance noise. Hence, only the noise in the very darkest patch will be visible.

MCC Color metrics


This image quality metric uses the CIELAB color metric to calculate how accurately the color conversion method reproduces the colors in a Macbeth Color Checker (MCC). Begin by creating a scene of an MCC rendered under a D65

4/20/2007

ISET

USER

MANUAL

43

illuminant (Scene | Scene | Macbeth Charts | D 65. After adjusting the optics, sensor and image processing settings, choose the pull-down ISET-Processor | Analyze | Compute from Scene. This produces the MCC image in the ISETProcessor window. Next, invoke the pull-down menu ISET-Processor | Analyze | Color and Luminance | MCC Color Metrics. The data in the Processor window will be compared with the exact data one would expect for an MCC under D65 illumination. The calculation assumes that the image white point is equal to the values measured at the white surface.
CIELAB color plane 100 Mean deltaE = 5.58 6 4 0 2 -100 -100 0 100 a (red-green) Achromatic series 0 0 5 10 15

b (blue-yellow)

100

Chromaticity (CIE xy) 0.8 0.6

L*

50

0.4 0.2

5 10 Gray patch

0 0.2 0.4 0.6 0.8 x

Figure Processor-6. The Analyze | Color and Luminance | MCC Color Metrics pull-down menu analyzes how accurately an MCC Color Checker (D65 illuminant) is rendered. The user is asked to select the four corners of the MCC (white, black, cyan, brown). The image is analyzed and error metrics for the MCC patches are plotted in the four panels of the window. The graph in the upper left shows the (a*,b*) color error. The graph in the lower left shows the measured and expected L* values for the six gray patches. The upper right shows the Eab error histogram. The graph at the lower right shows the xy chromaticity values. In the upper left and lower right panels the blue circles indicate the measured value and the small red lines show the distance from the measurement to the ideal value.

4/20/2007

ISET

USER

MANUAL

44

Metrics window
Not fully implemented

4/20/2007

ISET

USER

MANUAL

45

ISET Programming Guide


ISET is designed to be controlled either by a graphical user interface, or by writing scripts based on an open-source collection of Matlab routines. Using either method, users can calculate the transformations along the imaging pipeline and measure the effects of different components in the imaging system. While some tasks can be performed best using the graphical user interface, other tasks, say those that require looping through parameters or searching, are best approached using scripts. For a description of the ISET functions, go to http://www.imageval.com/public/Products/ISET/Manual/Functions.htm

4/20/2007

ISET

USER

MANUAL

46

ISET Scripts and Application Notes


A list of the separate documents containing application notes for various tasks, usually associated with ISET scripts.

Scene
High Dynamic Range Spectral (HDRS) Scene Database The ISET package includes images from our high dynamic range spectral (HDRS) image database. These images are complete spectral approximations the light radiance field. The full HDRS image database includes a collection of additional images and customized software tools. This document describes the methodology we used to acquire the data and estimate the spectral radiance for the images in the HDRS database.

Optics
ZEMAX Module Generating distorted image height, relative illumination, optical parameters and PSF data using ZEMAX Microlens Module In many digital image sensors an array of microlenses is placed near each pixel aperture on the sensor surface. The position and properties of this microlens array control two important functions of the optical path from the sensor surface to the photodetector. First, the microlenses concentrate photons incident within the pixel aperture onto a compact region at the silicon substrate. Second, the microlens array redirects the light path.

Processor
Selecting a Color Conversion Matrix This document gives a step-by-step description of using ISET to calculate a color correction matrix (CCM). The method is based on (a) simulating the responses to a Macbeth Color Checker under a specific illuminant, and (b)

4/20/2007

ISET

USER

MANUAL

47

using the simulated sensor responses to derive a 3x3 linear matrix (a CCM) that can be used for Manual Matrix Entry.

Metrics
Calculating Color Accuracy using the Macbeth ColorChecker This document describes how to use the CIELAB color metric to calculate how accurately the color conversion method reproduces the colors in a Macbeth Color Checker (MCC). Calculating the System MTF using ISO-12233 (Slanted bar) ISET implements the ISO 12233 (Slanted bar) method for calculating system the Modulation Transfer Function (MTF). This document describes a step-by-step procedure for how to perform this calculation. Measuring the Visibility of Noise with the Minimum Photometric Exposure (MPE) Spatial Resolution and Sensitivity Tradeoffs

4/20/2007

ISET

USER

MANUAL

48

Glossary and Formulae


.

4/20/2007

ISET

USER

MANUAL

49

Appendix
A. Matlab Data Conversion Routines
ieXL2ColorFilter: routine to run inside of Matlab to convert spectral data in Excel spreadsheet into spectral data as a Matlab file (file.mat). The data should have wavelength in the first column of the Excel spreadsheet and sensitivity (or transmissivity) in the subsequent columns (scaled between 0 and 1) Example: An Excel spreadsheet for a cyan, yellow, magenta filters Wavelength (nm)
780.0000 778.8889 777.7778 776.6667 775.5555 774.4445 773.3333 772.2222 771.1111 770.0000 378.8893

Cyan (%T)
0.6691643 0.6628207 0.6568444 0.6497047 0.6430920 0.6362457 0.6301257 0.6228593 0.6165825 0.6101215 0.1270044

Yellow (%T)
0.9876172 0.9883542 0.9884193 0.9895866 0.9885254 0.9898154 0.9890532 0.9891331 0.9910802 0.9900860 0.2420548

Magenta (%T)
0.9725687 0.9718713 0.9725651 0.9719566 0.9713735 0.9713428 0.9709100 0.9707350 0.9709256 0.9721787 0.5602559

4/20/2007

Index
A
Analyze 4 anti-aliasing filters 20 auto-exposure 31 Auto-exposure 35

E
Edit 3 electrical noise 25 energy 10 Energy2Quanta 16 etendue 32 exposureTime 36

B
Bayer color filter array 31

F
faulty pixel replacement 33 field height 22 field of view 12 field of view. 16 File 3 filter transmissivities 32 FOV 12

C
CIELAB 42 Code V 23 color conversion 34 Color conversion 37, 38 color filter array 31 Color processing 37, 39 Color rendering 37 Color test patterns 12 Color-balancing 35 conversion gain 28 cos4th 20

G
gainFPNimage 31 Graphical User Interface GUI 1 Gray World 39

D
dark voltage 28 demosaic 34 demosaicedImage 37 Demosaicing 36 Diffraction-limited optics 19 Diffuser 20 Display rendering 37 dlMTF 21

H
HDRS 14 Help 4

I
ieCompressData 10, 18 ieUncompressData 10, 18 illuminant SPD 14 illumination functions 13 image processing pipeline 34

50

image quality metrics 35 Image Quality Metrics 39 Image Sensor Array 25 imageGet 33 image-processing pipeline 33 imageSet 33, 36 imaging pipeline 8 indices of refraction of the metal layer 25 Installation 5 integrationTime 31, 35 irradiance 18, 25 ISA 30 ISET Image Systems Engineering Toolbox 1 ISO 12233 40, 41 ISO-12233 13 isoplanatic 22

P
paraxial imaging. 21 photons 10 physical units 27 PIXEL parameters. 28 pixel response 30 PIXEL structure 25 PIXEL variables 28 pixelCreate 25 pixelGet 25 pixelSet 25 Plot 3 Processor 33 Pull-Down Menus 3

Q L
Quanta2Energy 16 Luminance noise 41

R M
Mackay pattern 13 Manual Matrix Entry 38 Matlab imtool function 27 MCC Color metrics 42 MCC Luminance noise 41 MCC Optimized. 38 mean scene luminance 12 microlens 25 microlens toolbox 32 radiance image 10 Ray trace optics 22 read noise 28 RGB Images 15

S
Scene 9 Scene data 9 SCENE properties 12 SCENE.distance 10 SCENE.spectrum 10 SCENE.wAngular. 10 sceneCreate 9, 12, 13 sceneCreateMacbeth 13 sceneGet 9, 10, 11 sceneSet 9 sceneSetEditsAndButtons 12 sceneShowImage 12 sceneWindow 11 Sensor 25 sensor array 25 SENSOR array 30 SENSOR data 26 sensor metal layers 25 sensor noise 30 SENSOR parameters 29 SENSOR structure 25 Sensor window 26 SENSOR.quantization 31 sensor{Set,Get} 25 sensorCreate 29 sensorCreate. 25 sensorData2Image. 26

N
noise evaluation 14

O
offsetFPNimage 31 OI.data 18 oiCompute 16, 20, 23 oiCreate 18 oiDiffuser 20, 23 oiGet 18, 19 oiSet 18 oiWindow 18 Optics 18 opticsCos4th 23 opticsDLCompute 23 opticsGet 23 opticsOTF 23 opticsRayTrace 23 opticsSICompute 23 orrelated double-sampling 31

51

sensorGet 25 sensorImageWindow 25, 26 sensorSet 30, 35 sensorSet. 25 Session variable 3 Session Window 8 Shift-invariant optics 21 sigmaGainFPN 31 sigmaOffsetFPN 31 signal-to-noise (SNR) ratio 29 simulation pipeline 18 slanted bar target 40 Spatial resolution and the MTF 40 Spatial test patterns 13 spectral characteristics of the filters 25 sRGB 34 Stockman 39 Systems Approach 2

vcSESSION 7 visibility threshold for luminance noise 42 voltage swing 28

W
well capacity 28 White World 39

X
XYZ 39

Z