Start The criterion must be satisfied separately for all of the floors ULS Loads (vertical and horizontal) HEd 0,15 VEd Yes
No
EN1993-1-1 5.3.2(3) a)
Created on Monday, November 22, 2010 This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Access Steel Licence Agreement
Forces on bracing system due to ULS loads and global sway imperfection
Page 2
EN 1993-1-1 5.3.2(5)
/2 /2
Created on Monday, November 22, 2010 This material is copyright - all rights reserved. Use of this document is subject to the terms and conditions of the Access Steel Licence Agreement
EN 1993-1-1 5.3.3(4)
No
Repeat for each floor The local imperfections for inclined columns and spliced columns are not considered to be coexistent
Verify the bracing system members for the worst forces (due to global or local effects, in conjunction with ULS forces)