Professional Documents
Culture Documents
L - 09 Design of RC Retaining Walls
L - 09 Design of RC Retaining Walls
c
= 150 pcf;
f
c
= 4500 psi; f
y
= 60000 psi
11-6
3-6
400 lb/ft
2
(Live load surcharge)
13
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 01: Sizes
Trial dimensions for cantilever retaining wall can be calculated as
shown in figure below using thumb rules (reference: topic 24.7, pg 705, Treasures of
R.C.C Design by Sushil Kumar).
25
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 01: Sizes
Let,
B = 0.65h = 0.65 15 = 9.75
D = h/10 = 15/10 = 1.5
Top width of arm of retaining wall = 8
Width of arm at bottom = h/12 = 15/12 = 1.25 = 15
Length of toe = B/3 = 9.75/3 = 3.25
Equivalent depth of surcharge (h) = s /
s
= 0.4 / 0.120 = 3.33
26
14
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 01: Sizes (Stability checks)
Active earth pressure at base (see figure) of retaining wall for the case
of horizontal backfill surface with surcharge is given as:
(P
a
) = (1/2){K
ah
s
h(h + 2 h)}
Here h = total height of retaining wall = 15
P
a
= (1/2)(0.333 0.120 15)(15 + 2 3.33)
= 6.43 kips
27
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 01: Sizes (Stability checks)
And location of resultant from base of retaining wall is:
y = (h
2
+3hh)/3(h+2h)
= (15
2
+ 3 15 3.33)/3 x (15 + 2 3.33) = 5.77
Therefore, Overturning moment (OTM) = P
a
y = 6.43 x 5.77 = 37.10 ft-k
Now calculate the weights of areas and take their moment about toe
edge (shown next).
28
15
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 01: Sizes (Stability checks)
29
Table: Weights and moments about front edge (toe) of
retaining wall.
S.No Area (A) W = A
x (from
toe)
Wx
1 0.15 (8/12) 13.5 = 9 1.35 3.58 4.83
2 0.15 (1/2)(7/12)(13.5) = 3.94 0.591 4.11 2.43
3 0.15 9.75 1.5 = 14.625 2.2 4.875 10.73
4 0.12 3.25 2 = 6.5 0.78 1.625 1.27
5 0.12 (1/2)(7/12)(13.5) = 3.94 0.4728 4.31 2.04
6 0.12 5.25 16.83 = 88.35 10.602 7.125 75.54
W=R
v
=16.00 k
(Wx)=
96.84 k
13.5
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 01: Sizes (Stability checks)
F.O.S against OT = (Wx) / OTM
= 96.84 / 37.10 = 2.61 > 1.5 O.K.
Factor of Safety against sliding = R
v
/ P
a
Total horizontal force sliding the wall (P
a
) = 6.43 kips
= tan 0.577
Resistance to sliding = R
v
= 0.577 16.00 = 9.23 kips
Factor of safety against sliding = R
v
/ P
a
= 9.23 / 6.43 = 1.44.
This is slightly less than the recommended value of 1.5 and can be
regarded as adequate. However, FOS can be increased by providing
key.
30
16
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 01: Sizes (Stability checks)
Check for Allowable Pressure:
R
v
= 16.00 kips
To find the point of action a of R
v
, take moment of forces about the
toe of wall:
aR
v
= (Wx) OTM
a = {(Wx) OTM}/R
v
= (96.84 37.10)/ 16.00= 3.73
l/3 = 9.75/3 = 3.25 < 3.73
The resultant lies within the middle third.
31
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 01: Sizes (Stability checks)
q
max
= (4l 6a) R
v
/l
2
q
min
= (6a 2l) R
v
/l
2
l = 9.75; a = 3.73; and R
v
= 16.00 kips
q
max
= (4 9.75 6 3.73) 16.00/9.75
2
= 2.80 ksf
q
min
= (6 3.73 2 9.75) 16.00/9.75
2
= 0.48 ksf
Allowable pressure = 8000 psf or 8 ksf > q
max
, O.K.
If not, increase the width (B) of the retaining wall.
32
17
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 01: Sizes
Selected dimensions.
33
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 02: Loads (Toe Slab)
Factored Self weight of toe = Ignored
Factored earth fill load from above= Ignored
Factored soil pressure at exterior end of toe slab = 1.6 2.80 1= 4.48 k/ft
Factored soil pressure at interior end of toe slab = 1.6 2.03 = 3.25 k/ft
34
b = Unit
width
0.48
2.80
0.48
2.03
3.25
h=1.5
18
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 02: Loads (Heel)
Factored Self weight of heel = 1.2
conc
hb =1.2 0.15 1.5 1= 0.27 k/ft
Factored earth fill load = 1.6
fill
h
fill
b = 1.6 0.12 13.5 1= 2.592 k/ft
Factored surcharge load = 1.6
fill
h
surcharge
b = 1.6 0.12 3.33 1 = 0.639 k/ft
Total factored load on heel = 0.27 + 2.592 + 0.639 = 3.50 k/ft
35
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 03: Analysis (Arm)
Analysis for flexure
General equation of factored active earth pressure w.r.t bottom of arm is:
P
a
= 1.6 (1/2)(0.333 0.120h)(h + 2 3.33)
Taking moment at the base of the arm. Moment arm will be equal to:
y = {(h
2
+3h 3.33)/3}(h+2 3.33)
M
u
= P
a
y (neglecting passive earth pressure for safety)
= 1.6(1/2) (0.3330.120h) (h + 2 3.33) (h
2
+3h 3.33)/3(h+2 3.33)
= (0.0319h
2
+ 0.212h) (h
2
+9.99h)/3(h + 6.66)
Using this equation, bending moment diagram for arm can be drawn for
various values of h..
36
19
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 03: Analysis (Arm)
Analysis for flexure
37
M
u
= P
a
y = (0.0319h
2
+ 0.212h) (h
2
+9.99h)/3(h + 6.66)
0 < h < 13.5
y
P
a
45.49 kip-ft
0
3
6
9
12
16.34 kip-ft
6.11 kip-ft
1.24 kip-ft
M
nmin
= 39.14 kip-ft
33.54 kip-ft
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 03: Analysis of Arm for Shear
38
0
3
6
9
12
K
ah
s
(h + h)h/ (h+h) = K
ah
s
h
= 0.3330.120 3.33 = 0.133 kip
K
ah
s
(h + h)
= 0.3330.120 (13.5+3.33)
= 0.67 kips
0.63 kips
12.46
4.75 kip
Factored Shear (V
u
) =
1.6 4.75 = 7.6 kip
Load causing shear at critical section
Shear force diagram
20
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 03: Analysis (Toe)
Analysis for flexure and shear
39
V
u
= 6.51 kips
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 03: Analysis (Heel)
Analysis for flexure and shear
40
V
u
= 14.14 kips
21
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 4: Design (Arm)
Design for flexure:
For h = 13.5; M
u
= 45.49 ft-kip/ft = 545.87 in-kip/ft
A
smin
= 3{(4500)}/60000)bd = 0.0034 12 (15 2 0.5) = 0.51 in
2
/ft
M
n
= A
smin
f
y
(d-a/2) = 0.9 0.51 60 (12.5 - 0.66/2) = 469.7 in-k/ft (39.14
ft-kip/ft)
M
n
< M
u
, therefore using trial method A
s
= 0.846 in
2
, (#8 @11.17)
Maximum spacing for main steel reinforcement is:
3h = 3 x 15 = 45 ; 18
41
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 4: Design (Arm)
Similarly for other depths, the design is given in tabular form as below:
Therefore, from a depth of 13.5 ft to 9 ft, provide #8 @9.
And from 9 ft to top end, provide #8 @18.
42
Table: Design of main bars in arm of retaining wall.
Depth (h),
ft
Thickness
of arm
(w), in
Moment (M)
(in-k/ft)
A
smin
M
n,min
Governing
Moment
(in-k/ft)
Governing
Area of
steel
Design
spacing
Maximum
spacing
allowed
by ACI
Final
Spacing
for #8
Bars
0 8.00 0 0.224 58.81 58.81 0.224 42 18 18
3 9.56 14.89 0.287 98.98 98.98 0.287 32 18 18
6 11.11 73.36 0.351 149.52 149.52 0.351 26 18 18
9 12.67 196.09 0.414 210.45 210.45 0.414 24 18 9
12 14.22 403.74 0.478 281.75 403.74 0.66 14 18 9
13.5 15.00 545.87 0.51 321.3 545.87 0.846 11 18 9
22
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 4: Design (Arm)
Horizontal Bars:
According to ACI 14.3.3,
A
st
= 0.0025bh (for deformed bars larger than #5)
A
st
= 0.0025 12 15 = 0.45 in
2
/ft (3/4 @11.73)
Use 3/4 @9 c/c
43
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 4: Design (Arm)
Although not required by the Code for cantilever retaining walls, vertical steel
equal to 0.0012 times the gross concrete area will also be provided on exposed
face of wall.
A
s
= 0.0015 12 15 = 0.27 in
2
Using 3/4 dia bar with area A
b
= 0.44 in
2
Spacing =Area of one bar (A
b
)/A
st
= (0.44 in
2
/0.27 in
2
/ft) 12 = 19.5 (using #6 @19.5)
44
23
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 4: Design (Arm)
Design for Shear:
V
u
= 7.6 kips
Shear Capacity is given as:
V
c
= 2(4500) 12 12.5/1000 = 15.09 kips > 7.6 kips O.K.
45
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Retaining Wall Failure
Solution: Detailing in arm of retaining wall.
46
(#8 @ 9)
Horizontal
reinforcement
(#6 @ 9)
0.0012A
g
(#6 @ 18)
(#8 @ 18)
24
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 4: Design (Toe)
Design for flexure:
M
u
= 258 in-k/ft
A
smin
= 3{(4500)/60000)bd = 0.0034 12 (18 3 0.5) = 0.592 in
2
/ft
M
n
= A
smin
f
y
(d a/2) = 0.9 0.592 60 (14.5 0.774/2) = 451.16 in-k/ft
M
n
> M
u
, therefore A
s
= A
smin
= 0.592 in
2
/ft (#8 @16)
Maximum spacing for main steel reinforcement:
3h = 3 18 = 54; 18
Finally use #8 @16 c/c.
Also provide #4 @18 c/c as supporting bars for main bars.
47
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 4: Design (Toe)
Design for Shear:
V
u
= 6.51 kip
V
c
= 2 0.75 (4500) 12 14.5/ 1000 = 17.51 kip > 6.794 kip, O.K.
If not O.K, then increase thickness of toe.
48
25
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 4: Design (Heel)
Design for Flexure:
M
u
= 578.8 in-kip/ft
A
smin
= 3{(4500)/60000)bd = 0.0034 12 (18 3 0.5) = 0.592 in
2
/ft
M
n
= A
smin
f
y
(d-a/2)= 0.9 0.592 60 (14.5 0.774/2) = 451.16 in-kip/ft
M
n
< M
u
, therefore using trial method A
s
= 0.765 in
2
,(#8 @12.39)
Maximum spacing for main steel reinforcement:
3h = 3 x 18 = 54 ; 18
Finally use #8 @12 c/c.
Also provide #4 @18 c/c as supporting bars for main bars.
49
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 4: Design (Heel)
Design for Shear:
V
u
= 14.14 kips
V
c
=2 0.75 (4500) 12 14.5/ 1000 = 17.51 kips > 14.14 kips, O.K.
If not, increase thickness of heel.
50
26
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
Example
Solution:
Step No 4: Design (Heel)
Development length check of Arm reinforcement in Heel slab
Thickness of heel slab = 1-6 = 18
l
dh
=(0.02f
y
/f
c
)d
b
> 8d
b
or 6 in (whichever is greater) (ACI 12.5)
l
dh
= (0.0260000/ (4500))(1) = 17.88 < h
heel
.
Increase depth or change steel grade.
If grade 40 steel is used, l
dh
= (0.0240000/ (4500))(8/8) = 11.92.
Therefore either revise the design, specially of arm, using grade 40
steel or increase depth of base slab to at least 22. When depth is
increased, the revision of design is not required.
51
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
52
27
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
References
ACI 318
Design of Concrete Structures (13
th
Ed.) by Nilson, Darwin
and Dolan.
53
Prof. Dr. Qaisar Ali Reinforced Concrete Design II
Department of Civil Engineering, University of Engineering and Technology Peshawar
The End
54