You are on page 1of 21

HAP ) .

( Hourly Analysis Program


-: .
-: ,

.
-1
-2
-3

Weather
Spaces
Systems

-4 . Plant

Weather -:
-:
.

Weather -:

Design Parameters
Design Temperatures
Design Solar
Simulation

Design Parameters

-: Region
.
-: Location .
-: City .

.
-: Latitude ) . (
-: Longitude ) . (
-: Elevation .
-: Summer Design DB .
-: Summer Coincident WB .
-: Summer Daily Range
.
-: Winter Design DB .
2

-: Winter Coincident WB .
-: Atmospheric Clearness Number
.
ACN = 1.5 for very clear.
ACN = 1 for typical conditions.
ACN = 0.85 for very hazy conditions.
-: Average Ground Reflectance
) . (0.2
-: Soil Conductivity .
) .( 0.8 W/M/K
-: Design Cooling Calculation Months .
-: Time Zone .
-: Daylight Savings Time ,
.
-: DST Begins
.
-: DST Ends
.
-: Data Source
, . 2001 ASHRAE Handbook

-:
City
.... , .

Design Temperatures

Design Temperature -:
-:Monthly Max/Min -1 Dry Bulb & Wet Bulb
.
-:Hourly Detail View -2 Dry Bulb & Wet Bulb
.

-:
,
.

Design Solar

Design Solar -:
-:Design Day Maximum Solar Heat Gains BTU/hr/ft2
.



= . BTU/hr/ft2 36.4
= * 36.4 . BTU/hr

Space -:
-: ,
......

Space 7-:

General
Internals
Wall, Window, Doors
Roofs, Skylight
Infiltration
Floors
Partitions

General

- :Name .
- :Floor Area .
- :Average Ceiling Height
.
- :Building Weight
.
, Slide Light or Medium or Heavy

-: Building Weight

.
- :Outdoor Air Ventilation Requirements ,

.

-:
-1 Space Usage User Defined
, .
-2 Space Usage ,

Space Usage
.
Booking/Waiting
.
OA Requirement 1 = 7.5 CFM/Person
OA Requirement 2 = 0.06 CFM/Ft2

-:
-:
- :CFM .
- :CFM/Person .
-: CFM/Ft2 .
- :% of Supply Air .
% of supply air -: 100 %
system total fresh air ,
, , .

Internals

-:

Overhead Lighting
Task Lighting
Electrical Equipment
People
Miscellaneous Loads

10

- :Overhead Lighting
-:
Fixture Type
Wattage
Ballast Multiplier
Schedule

- :Fixture Type
, -:
-:Recessed, Unvested -
-:Recessed, Vented -
-:Free Hanging -
- :Wattage
.
-:
-:Watt - .
-: Watt/Ft2 - .

.

General

11

- :Schedule .

- :Task Lighting
-:
Wattage
Schedule

- :Wattage
.
-:
-:Watt - .
-: Watt/Ft2 - .
- :Schedule .

12

- :Electrical Equipment
,
.
-:
Wattage
Schedule

- :Wattage .
-:
-:Watt - .
-: Watt/Ft2 - .
- :Schedule .

13

- :People
.
-:
Occupancy
Activity Level
Sensible
Latent
Schedule

-:Occupancy
.
-:
-:People - .
-: People/Ft2 - .
- :Activity Level
,
.
Activity Level
.
- :Sensible .
- :Latent .
14

-:
Activity
Level Sensible & Latent Heat
User Defined Activity Level
.
W/Person

.


-
:Schedule

- :Miscellaneous Loads
.
-: .
-:
Sensible
Latent
Schedule

- :Sensible .
- :Latent .

-:
Sensible
Latent ,
Sensible Heat Latent Heat ,
.Sensible & Latent Heat

15

- :Schedule .

....
,
s 9s s s 5s ,s
Scheduless ss ss ss ss ss ss ss ss ss ss ss ss
, . Schedule
-: Schedule Schedule
. None, Create New Schedule

- :None Schedule
,Internal People .Schedule


People Schedule
Alarm .

16

-:Schedule
Schedule -:
Schedule Type
Hourly Profiles
Assignments

17

- : Schedule Type -:

-:Schedule Name -
-:Schedule Type - 3 Schedule
, Fractional .Internal
.Schedule

- : Hourly Profiles

18

Profiles Profile
, Profile ,
Profile
.

9 5 ,
8 , 9
1 4 , Schedule 9 1
,%50 2 5 4
8 , Schedule 2 5
,%100 6 Schedule
. %0


9 9 Schedule
.Schedule

19

-: Assignments

,
, Profile Profile .


Schedule
None , Create New Schedule
Schedule Schedule,
.

20

, -:
-1 ).(weather , space , system , plant
Cd -2 + .
-3 .
-4 6.
-: /