This formula calculates the allowable span L in feet for a pipe based on factors including the hot basic allowable stress S in psi, the support beam width d and bearing width b in inches, the corroded wall thickness t plus any repad in inches, the unit weight W of the pipe and contents in lb/ft, and the pipe radius R in inches. The formula limits the local stress due to bearing to 67% of the hot condition allowable stress S.
This formula calculates the allowable span L in feet for a pipe based on factors including the hot basic allowable stress S in psi, the support beam width d and bearing width b in inches, the corroded wall thickness t plus any repad in inches, the unit weight W of the pipe and contents in lb/ft, and the pipe radius R in inches. The formula limits the local stress due to bearing to 67% of the hot condition allowable stress S.
This formula calculates the allowable span L in feet for a pipe based on factors including the hot basic allowable stress S in psi, the support beam width d and bearing width b in inches, the corroded wall thickness t plus any repad in inches, the unit weight W of the pipe and contents in lb/ft, and the pipe radius R in inches. The formula limits the local stress due to bearing to 67% of the hot condition allowable stress S.
d - support beam width, inches b - bearing width, 1.5% of pipe OD, inches t - corroded wall thickness, plus any repad, inches W - unit weight of pipe and contents, lb/ft R - pipe radius, OD/2, inches This limits the local stress due to bearing to 67% of S(hot condition)