Professional Documents
Culture Documents
1 Heat Balance
1 Heat Balance
Production Department
Heat balance of Rotary kiln (Dia 4.8m x 72m)with double string 5 - stage precalciner
Data:o
30
Ambient Temp C
5700
O2 : %
2.6
237.5
CO2 : %
28
1.6
380
CO : %
Excess air
factor
0.05
1/[1-{(79/21)x(2.6/100-28-2.6-0.05)}]=1.16
0.55%
29.88
0.186 + (0.00054x100)=1.1914
0.1258
kiln feed
Air
0.237 + (0.000023 x t)
2.5
water vapour
0.42 + (0.000185 x t)
70
CO2
0.19 + (0.00011 x t)
60
Exit gases
0.23 + (0.00005 x t)
335
Coal
0.262 + (0.00039 x t)
100
Oil
1.31
275
6000
0.42
Density
Air
Page 1 of 4
1.293 kg/m 3
SiO2 %
22
Al2O3 %
5.26
Fe2O3 %
3.4
CaO %
65.18
MgO %
2.54
539 kcal/kg
752 m
Barometric
pressure
936 mbar
Maximum
wind velocity
Average
relative
humidity
Grate Cooler
TC-12108
40 m/sec
50%
128.6 m2 (44.32 tpd/m 2)
205200m 3 ID fan
/hr
capacity
Calculations
Kcal/kg Clinker
%age
754.8
98.07
1.08
0.14
0.1258 x 6000
0.1258x[0.262+(0.0009 x
60]x(60-30)
1.6x[0.21+(0.00007x70)]x
(70-30)
13.75
1.79
Total Heat In
769.63
100
Heat OUTPUT
(489x5.26)/100 +
(714x65.18)/100 +
(539x2.54)/100 - 73
431.79
56.1
Description
Calculation
Heat INPUT
Page 2 of 4
4.74
0.61
1.29
0.17
1.02
0.13
0.28
0.04
38.36
4.98
100.85
13.1
6.22
0.81
13.4
1.74
100.98
13.12
40 x 0.05
0.26
68.7
8.94
769.63
100
((44/56 x 65.18/100)) +
44 x 2.54/40x100) = 0.54
kg/kg clinker
0.54 x [0.19+(0.00011 x
335] x (335-30)
1.41 kg air / 1000 kcal
coal
1.55 kg gases / 1000 kcal
coal
1.55 x 754.8 / 1000 =
1.17 kg/kg clinker
(1.16 - 1) x 1.41 x
754.8/1000 = 0.17 kg/kg
clinker
1.17 + 0.17 = 1.34kg/kg
clinker
1.34 x [0.23 + (0.00005 x
335)] x (335 - 30)
0.1 x [0.186 + (0.000054
x 335)] x (335 - 30)
Page 3 of 4
Description
Pre-heater:- Volume of Exit gases from
single kiln.
Pre-heater:- Volume of Exit gases from
both kilns.
Volume of pre-heater exit gases at
o
335 C and 6000pa from single kiln
G
H
Calculation
Results
306375Nm /hr
2x306375
612750Nm /hr
693976 m /hr
2 x 693976
1387952 m 3/hr
311125 Nm 3/hr
2 x 311125
622250 Nm 3/hr
673388 m 3/hr
2 x 673388
1346776 m 3/hr
(B+F) Total volume of exit gases from both preheaters and both AQCs.
1235000 Nm3/hr.
Calculation
Results
Pre-heater: - 693976m 3/hr gases at 335 oC and 6000pa after pre-heater pass through PH 1.34 kg flue gases/kg clinker
waste heat exchanger and comes out from it with 223 oC and 7000pa. Volume of gases
after PH waste heat exchanger = (693976 x 996)/608 x (496/1006) = 560511 m 3/hr
189100/237500
0.796Nm3/kg clinker
48647858 kcal/hr
= 48.65 million kcal/hr
= 48.65x1000x4.2/3600
= 56.76 MW
26.50%
26.5/100 x 56.76
Page 4 of 4
15.04 MW