Subject: SAND CONE TEST RECORD
Project : Infrastructure Facilities E Location
Client: Mobil Cepu Ltd.

Q1-C.0.10
Doc. No. :
Contract No. :

: RAW WATER BASIN

Weather

Area/Facilit: VERTIKAL DRAINAGE (CHIMNTested By


Section

: ZONA 1

Layer

DESCRIPTION

UNIT

Date of Test

Sta:

Thursday, July 24,

Sand Cone No.

39.300
Test Point No./ Sta
0+260
7521.0
Weight of sand + bottle + cone
W1
gr
2332.0
Weight of remaining sand + bottle + cone
W2
gr
5189.0
Weight of sand in cone+plate +hole
W3
gr
1.401
Density of sand ( p ) =
(p)
gr/cm3
3704
Volume of (cone+plate + hole)
V1 = (W3 / (p )
cm3
1127.81
Volume of ( Cone + plate )
V2
cm3
2576.0
Volume of hole = Volume of Soill
V3 = V1 - V2
cm3
4775.0
Weight of ( Soil + tare )
W4
gr
7.8
Weight of tare
W5
gr
4767.2
Weight of wet Soil = W6
W6 = W4-W5
gr
3
1.851
Density of wet Soil ( t )
t= W6 / V3
gr/cm
10.50
Water Content ( w ) ( Speedy Test )
w
%
3
1.675
Field Dry Density ( d field )
d field=t*100/100+w
gr/cm
1.682
Degree of compaction
yd Lab Max
gr/cm3
1.511
Degree of compaction
yd Lab Min
gr/cm3
96.19
Relative Density RD=(((yd max x ((yd fild - d min))/((yd fild x (yd max - yd min))
%
Elv.

Average Degree of Compaction

Requared percent of Compaction

75%

Water Content Test


Sta

test Number
Point
of
or
sta
1

Weight

Weight of

Weight ofWeight ofWeight of Water

of

wet Soil +

Dry Soil + water

tare

tare

tare

(gr)

(gr)

(gr)

tare
2

to

Note:
1. Specification
:

75%

2. Actual

- Point 1 =
- Point 2 =
- Point 3 =

Result

96.19 %
- %
- %

Point 1 =
Point 2 =
Point 3 =

Accepted
-

Dry Soil content

(gr)
6

(4-5)

(gr)
7

(%)

(5-3) (6/7)*100

Prepared By

Checked / Approved By

Sub - Contractor

Consortium RH

Print Name

Signature

Date

7/24/2014

Witnessed/Review

Mobil Cepu L

Project No.
: Fine
: Darmawan Cs.
: 16

0+240~0+280
Thursday, July 24, 2014

75%

Witnessed/Reviewed by
Mobil Cepu Ltd

CONSORTIUM
PT.REKAYASA INDUSTRI
PT.HUTAMAKARYA

QI-C.0.13
Doc.No.
Contract No.

C-320802

Subject : Field Permeability

FIELD PERMEABILITY TEST


FALLING HEAD METHOD

LOCATION

: RAW WATER BASIN

DATE OF TEST

AREA / FACILITY

: VERTIKAL DRAINAGE (CHIMNEY)

Tested By

SECTION

: ZONA 1

Elv.

Sta. of test point

: 0+240~0+280

vol
Point No :

: 1000

H
(cm)

No

1
2
3

Note :

D
(cm)

R
(cm)

T
(cm)

T
(sec)

Q
(ml/sec)

T
o
( C)

(cm/sec)

20.0

15.20

7.60

20.00

53.20

18.80

31.00

0.776

5.20E-03

20.0

15.20

7.60

20.00

67.41

14.83

31.00

0.776

4.10E-03

20.0

15.20

7.60

20.00

74.32

13.46

31.00

0.776

3.72E-03

1)

Tested by

Checked / Approved by

Contractor

Consortium RH

Print Name

Signature

Date

KT

T : 20o

7/24/2014

QI-C.0.13A

.No.

tract No.
C-3208020
Project No. :

###
Darmawan Cs.
39.300

K20oC

Remarks

(cm/sec)
4.03E-03

0+260

3.18E-03
2.89E-03

ToC
T : 20o
40
T : 20o
Witnessed/Reviewed by
Mobil Cepu Ltd

0
0.793
0.654
0.648

1
0.776
0.642
0.636

2
0.760
0.630
0.624

3
0.744
0.618
0.612

4
0.731
0.608
0.603

5
0.724
0.597
0.592

6
0.700
0oC
1.794

7
0.686
5oC
1.519

8
0.673
10oC
1.310

9
0.660
15oC
1.145