You are on page 1of 2

Uncertainty Analysis

Parameter:

Pins and Plugs Diamter Measure

Method:

Direct

Standards:

ATL1584

A7177

Date:

3/11/2008

UUT:
Range:

54-0150
0-10"

This anlaysis is based on Type B analysis of the parameter in question.


Any historical Type A or pooled uncertainties that may apply will also be included and noted.
Uncertainty Model:

Lu=Su+Ru+Eu+Sm

Measurement Model:

Lu
Su

Length Uncertainty
Standard Uncertainty

La

Length applied

Ru
Eu
Sm

Resolution Uncertainty
Environmental Uncertainty *
Stability of Measurements

Li

Length andicated

Uncertainty Analysis Table

11.6 uIn per In/deg C , Lab Env is 20 deg +/- 1 deg C *


Max 1 degree shift from Standards cal temp.

Symbol

Estimate

Type

Xi
Sm
Su
Ru
Eu
uc
U

xi
0.E+00
0
0
1

A
B
B
B

Inches

2
3
4
5
6
7
8
9
10

Contribution

Std. Dev

Probability
Distribution

Divisor

1.26E-05
In
Normal
1.000
2.32E-05
In
Rec
1.732
2.0E-05
In
Rec
1.732
1.16E-05
In
U
1.414
Combined Standard Uncertainty (1 Sigma) in Inches
Expanded Uncertainty (k=2) in Inches
Uncertainty:
Welch-Satterwaite
100.612607
Uc:
2.91671E-019
Ua:
2.56000E-020
Ub1:
3.21929E-020
Ub2:
1.77799E-020
Ub3:
4.52933E-021

9.99998
10.00000
9.99998
10.00000
10.00000
10.00002
10.00000
10.00000
9.99998
10.00000

Stundent's T:
Mean:

Units
Value

10.00

Observations:
1

Infinite

2.00

at 95.45% CL

10.000
1.2649E-05

Degree of Freedom:

La=Li

Su= 4.2 +1.9L uIn for Gage blocks


Atmospheric Pressure/humidity noted sources of uncertainty but found to be negligible in this analysis
User error taken into account on stability of measurement, Where different technicians found deviations of 20 uIn.

Sensitivity
coefficient
ci
1
1
1
1

Uncertainty
contribution ui(y)

1.26E-05
1.34E-05
1.15E-05
8.20E-06
2.3239E-05
4.6479E-05

4.65E-05 Inches

Flatness/Parellelism/Bilateral deviation verified with optical flats and found to be of negligible values to include in budget.