Professional Documents
Culture Documents
STM 1 Configuration
STM 1 Configuration
CPE STM1
EI NO.
ENGINEERING INSTRUCTIONS
Page 1 of 11
Issue 1
Date
ENGINEERING INSTRUCTIONS
TRANSMISSION
CPE STM1
EI NO.
Page 2 of 11
Issue 1
Date
ENGINEERING INSTRUCTIONS
TRANSMISSION
CPE STM1
EI NO.
Page 3 of 11
Issue 1
Date
ENGINEERING INSTRUCTIONS
TRANSMISSION
CPE STM1
EI NO.
6.2.1
6.2.2
Page 4 of 11
Issue 1
Date
TRANSMISSION
CPE STM1
EI NO.
ENGINEERING INSTRUCTIONS
Page 5 of 11
Issue 1
Date
TRANSMISSION
CPE STM1
EI NO.
ENGINEERING INSTRUCTIONS
Measure the Input Jitter tolerance with the help of PDH/ SDH Analyser.
Frequency
Measured value
Limit
For 2.048Mb/s:
f1 20 Hz
------------f2 93 Hz
------------f3 3700 Hz ------------f4 100 Khz -------------
>/= 1.5 UI PP
>/= 1.5 UI PP
>/= 0.2 UI PP
>/= 0.2 UI PP
For 34.368Mb/s:
f1 100 Hz
------------f2 1.0 Khz
------------f3 10 Khz
------------f4 800 Khz -------------
>/= 1.5 UI PP
>/= 1.5 UI PP
>/= 0.2 UI PP
>/= 0.2 UI PP
For 139.264Mb/s:
f1 200 Hz
------------f2 500 Hz
------------f3 10 Khz
------------f4 800 Khz
-------------
>/= 1.5 UI PP
>/= 1.5 UI PP
>/= 0.2 UI PP
>/= 0.2 UI PP
For 155.520Mb/s:
f1 500 Hz
------------f2 6.5 Khz
------------f3 65 Khz
------------f4 1300 Khz -------------
>/= 1.5 UI PP
>/= 1.5 UI PP
>/= 0.2 UI PP
>/= 0.2 UI PP
7.0
7.1 Mapping:
The CPE SDH system Trans optical port is connected to the Receive STM1 optical input of the SDH
analyser and the PDH 2/34/140/155Mb/s Trans electrical output of the Analyser is connected to the PDH
2/34/140/155Mb/s.tributaries electrical RX of CPE SDH equipment.
Measure the BER for 5min.and the result better than 1x10-10.
7.2 De-mapping:
The Optical STM1 Trans output of the SDH analyzer is connected to the receive optical port of the CPE
SDH system and the PDH 2/34/140/155Mb/s. tributaries electrical TX of CPE SDH equipment is
connected to the 2/34/140/155Mb/s receive electrical input of the Analyser.
Measure the BER for 5min.and the result better than 1x10-10.
Page 6 of 11
Issue 1
Date
TRANSMISSION
CPE STM1
EI NO.
ENGINEERING INSTRUCTIONS
8.0 Alarms:
Connect the Optical STM1 trans output of the SDH Analyser to the receive optical port of CPE SDH
system and vice versa, inject alarm with Anomaly/ Defect analyser and record the alarms.
(Note: For the electrical 155Mb/s the above set up is same but instead of optical port, electrical port to be
connected both in Analyser and CPE SDH system.)
Monitor the current alarm through PC/ Laptop by local access and select
Fault management Alarms
The Trans set up of the SDH analyser as
TX STM1 Optical / Electrical
AU4 VC12 2Mb/s PRBS 15-1
Ch 1/1/1
RX STM1 Optical / Electrical
AU4 VC12 2Mb/s PRBS 15-1
Ch 1/1/1
Alarm
Simulated
LOS
LOF
MS-AIS
MS-RDI
AU LOP
AU AIS
HP UNEQ
HP PLM
HP RDI
TU LOM
TU AIS
LP UNEQ
LP RDI
Alarm
Information
Loss of signal
Loss of frame
Alarm Indication signal (Line)
Remote defect indication (Line)
Loss of pointer
Alarm indication signal
Signal label unequipped
Payload mismatch
Remote defect indication
Loss of Multi-frame
Alarm Indication signal (Term)
Signal label unequipped
Remote defect indication (Term)
Severity
Critical
Critical
Critical
Critical
Major
Major
Major
Major
Major
Major
Major
Major
Major
Object
STM1-3-1/2
STM1-3-1/2
STM1-3-1/2
STM1-3-1/2
AU4 1-3-111
AU4 1-3-111
AU4 1-3-111
AU4 1-3-111
AU4 1-3-111
TU12 1311111
TU12 1311111
TU12 1311111
TU12 1311111
Acknowledgement
status
Unacknowledged.
Unacknowledged
Unacknowledged
Unacknowledged
Unacknowledged
Unacknowledged
Unacknowledged
Unacknowledged
Unacknowledged
Unacknowledged
Unacknowledged
Unacknowledged
Unacknowledged
THROUGH TEST:
8.1. Check of Optical receive power:
For continuous power,
Click on Provisioning--> STM Ports ----> STM1-3-1---->
*) Admin Status:
Admin Up
*) ALS Mode:
disable
Click on Provisioning--> STM Ports ----> STM1-3-2---->
*) Admin Status:
Admin Up
*) ALS Mode:
disable
disconnect the fiber line receive and connect it to the optical power meter. Measure the receive power
before connector and introduce suitable optical pad for normal working condition. Measure the receiver
in power after pad and record the value. After the receive power measurement, set both the optical Trans
ports
*) ALS mode:
Automatic
With the help of optical Time Domain Reflecto meter measure the route length and calculate the expected
receive power and compare the result.
Page 7 of 11
Issue 1
Date
ENGINEERING INSTRUCTIONS
TRANSMISSION
CPE STM1
EI NO.
8. 2 BER Check:
With the distant end loop at 2, 34, 140, 155 measure the Bit error ratio for at least 5 minutes each at normal
clock & +/- the prescribed offset value and record.
No error should be observed.
8.3 Check of AIS clock:
Measure the AIS clock with the help of PDH/SDH analyzer or Frequency counter at the RX electrical port
of each tributaries with data input fail at distant end.
Limits:
2.048 Mb/s-------------+/- 50 ppm
34.368 Mb/s-----------+/- 20 ppm
139.264 Mb/s----------+/- 15 ppm
155.520 Mb/s----------+/- 20 ppm
8.4. Output Jitter Measurement:
With the distant end loop at 2, 34, 140, 155 measure the Output Jitter tolerance with the help of PDH/ SDH
Analyser.
Filter For 2.048 Mb/s
Limit
Hp1Lp: -----------------------</= 0.75 UI PP
Hp2Lp: -----------------------</= 0.20 UI PP
Filter For 34.368 Mb/s
Limit
Hp1Lp: -----------------------</= 0.75 UI PP
Hp2Lp: -----------------------</= 0.15 UI PP
Filter For 139.264 Mb/s
Limit
Hp1Lp: -----------------------</= 0.75 UI PP
Hp2Lp: -----------------------</=0.075UI PP
Filter For 155.520 Mb/s
Limit
Hp1Lp: -----------------------</= 0.75 UI PP
Hp2Lp: -----------------------</= 0.15 UI PP
8.5. Input jitter measurement:
With the distant end loop at 2, 34, 140, 155 measure the Input Jitter tolerance with the help of PDH/ SDH
Analyser.
Frequency
Measured value
Limit
For 2.048Mb/s:
f1 20 Hz
------------- >/= 1.5 UI PP
f2 93 Hz
------------- >/= 1.5 UI PP
f3 3700 Hz ------------- >/= 0.2 UI PP
f4 100 Khz ------------- >/= 0.2 UI PP
For 34.368Mb/s:
f1 100 Hz
------------f2 1.0 Khz
------------f3 10 Khz
------------f4 800 Khz -------------
>/= 1.5 UI PP
>/= 1.5 UI PP
>/= 0.2 UI PP
>/= 0.2 UI PP
For 139.264Mb/s:
f1 200 Hz
------------f2 500 Hz
------------f3 10 Khz
------------f4 800 Khz
-------------
>/= 1.5 UI PP
>/= 1.5 UI PP
>/= 0.2 UI PP
>/= 0.2 UI PP
Page 8 of 11
Issue 1
Date
TRANSMISSION
CPE STM1
EI NO.
ENGINEERING INSTRUCTIONS
For 155.520Mb/s:
f1 500 Hz
------------f2 6.5 Khz
------------f3 65 Khz
------------f4 1300 Khz -------------
>/= 1.5 UI PP
>/= 1.5 UI PP
>/= 0.2 UI PP
>/= 0.2 UI PP
192.168.4.200
255.255.255.0
192.168.4.254
Page 9 of 11
Issue 1
Date
TRANSMISSION
CPE STM1
EI NO.
ENGINEERING INSTRUCTIONS
12
E1
Port 1
Enable
Port 2
Enable
Pl. Note: The Segment No. for all the Nodes connected through the Optical Fibers should be same (i.e. two
digit no.)
For Selective Calling:
For Omni-Bus Calling:
( ex. #12123)
( ex. #12251)
Page 10 of 11
Issue 1
Date
ENGINEERING INSTRUCTIONS
TRANSMISSION
CPE STM1
EI NO.
0.018
0.023
0.0023
10. ABBREVIATION:
AIS Alarm Indication Signal
ALS Auto Laser Shutoff
BER Bit Error Rate
CPE Customer premises Equipment
EOW Engineering Order Wire
IP Internet Protocol
NMS Network Management System
PDH Plesiochronous Digital Hierarchy
RX Receive
SDH Synchronous Digital Hierarchy
TX Trans
BIBLIOGRAPHY:
TJ100CP, TJ100MC-1, Installation Procedures, Hardware description manual.
Page 11 of 11
Issue 1
Date