Professional Documents
Culture Documents
5,297
Cold Flow
(ft3/jam)
Counter current
Hot Water
Temperature (oF)
Cold Water
Temperature (oF)
TH1
TH2
TC1
TC2
TH1
TH2
TC1
TC2
7,2042
104
104,18
85,64
99,68
135,5
127,04
68,36
102,74
6,5685
121,28
113,54
73,94
98,06
144,68
129,92
86,72
102,74
5,9328
115,88
115,16
74,12
90,86
141,44
125,78
86,36
101,3
5,2972
130,28
116,78
82,94
109,04
152,6
145,22
84,2
92,12
4,4496
140,54
119,3
85,1
101,48
154,4
146,84
86,36
93,74
2.4.1.2 Jacket
Tabel 2.4 Hasil Pengamatan Jacket Batch Operation pada 0 dan 300 rpm
0 rpm
Time
(s)
Flowrate
(ft3/jam)
300 rpm
Cold Water
Temperature(oF)
TH1
TH2
TC5
TH1
TH2
TC5
154,22
154,58
91,94
142,52
149
126,68
163,76
176,72
100,76
154,4
138,56
132,62
144,32
156,74
103,784
157,1
150,98
136,94
145,04
139,82
109,94
169,16
173,48
107,78
145,76
152,78
113,9
163,94
157,64
85,64
136,04
160,52
119,84
141,08
140,18
86,54
2
3
5,297
Tabel 2.5 Hasil Pengamatan Jacket Continuous Operation pada 0 rpm dan 300 rpm
0 rpm
Time
(s)
Flowrate
(ft3/jam)
Hot Water
Temperature (oF)
300 rpm
Cold Water
Temperature (oF)
Hot Water
Temperature (oF)
Cold Water
Temperature(oF)
TH1
TH2
TC1
TC4
TH1
TH2
TC1
TC4
172,22
171,5
68,36
75,92
159,08
206,24
77,36
100,4
208,76
180,32
69,08
86,18
157,82
143,96
87,8
87,62
176
164,3
77,36
80,06
177,62
165,74
96,26
100,22
181,58
182,12
86,36
102,02
156,74
140,72
87,62
100,22
199,04
174,38
89,96
89,78
161,06
139,28
91,4
86,9
199,58
193,82
86,72
98,24
192,74
139,82
90,14
88,52
2
3
5,297
Hot Flow
(ft3/jam)
TH1
(oF)
TH2
(oF)
THavg
(oF)
(lb/ft3)
Cp
( Btu/lb oF)
mh
(lb/jam)
qh
(Btu/jam)
5,297
104
121,28
115,88
130,28
140,54
104,18
113,54
115,16
116,78
119,3
104,09
117,41
115,52
123,53
129,92
61,9449
61,7518
61,7792
61,6596
61,5525
0,9986
0,9989
0,9989
0,9991
0,9995
328,1325
327,1096
327,2548
326,6214
326,0543
-58,9807
2529,1597
235,3632
4405,6356
6921,8484
1
2
3
4
5
Tabel 2.7 Hasil Perhitungan Kecepatan Perpindahan Panas Cold Fluid pada Concentric Cocurrent
No,
Cold Flow
(ft3/jam)
TC1
(oF)
TC2
(oF)
TC avg
(oF)
(lb/ft3)
Cp
( Btu/lb oF)
mc
(lb/jam)
qc
(Btu/jam)
1
2
3
4
5
7,2042
6,5685
5,9328
5,2972
4,4496
85,64
73,94
74,12
82,94
85,1
99,68
98,06
90,86
109,04
101,48
92,66
86
82,49
95,99
93,29
62,0811
62,1603
62,1944
62,0415
62,0736
0,9986
0,9986
0,9987
0,9993
0,9994
447,2415
408,2995
368,9889
328,6442
276,2041
6270,4177
9834,2978
6168,7396
8571,4410
4521,2908
Tabel 2.8 Hasil Perhitungan Koefisien Perpindahan Panas Overall pada Concentric Cocurrent
No,
LMTD
(oF)
Uo
(Btu /jam ft2 oF)
Ui
(Btu /jam ft2 oF)
Um
(Btu /jam ft2 oF)
1
2
3
4
5
9,8571
28,5022
32,2460
21,8669
33,1460
-8,8518
131,2706
10,7977
298,0513
308,9312
1109,7444
601,9199
333,7299
683,8179
237,9613
-6,2162
92,1844
7,5827
209,3057
216,9461
Tabel 2.9 Hasil Perhitungan Keefektifan Heat Exchanger pada Concentric Cocurrent
No,
(mxCp)hot
(Btu/jam oF)
(mxCp)cold
(Btu/jam oF)
(mxCp)min
(Btu/jam oF)
q actual
(Btu/jam)
Thavg - Tcavg
(oF)
Keefektifan ()
Rf
(jam ft2
o
F/Btu)
1
2
3
4
5
327,6707
326,7648
326,8934
326,3434
325,8874
446,6110
407,7238
368,5030
328,4077
276,0251
327,6707
326,7648
326,8934
328,4077
276,0251
-58,9807
2529,1597
235,3632
4405,6356
4521,2908
6,3500
17,4500
18,3500
15,3000
20,3500
-0,0283
0,4436
0,0392
0,8768
0,8049
0,0026
0,0027
0,0027
0,0026
0,0026
Tabel 2.10 Hasil Perhitungan Kecepatan Perpindahan Panas Hot Fluid pada Concentric Counter Current
No,
1
2
3
4
5
TH1
(oF)
135,5
144,68
141,44
152,6
154,4
5,297
TH2
(oF)
THavg (oF)
(lb/ft3)
Cp
( Btu/lb oF)
mh
(lb/jam)
qh
(Btu/jam)
127,04
129,92
125,78
145,22
146,84
131,27
137,3
133,61
148,91
150,62
61,5299
61,4289
61,4907
60,7489
60,6271
0,9996
0,9999
0,9997
1,0006
1,0007
325,9345
325,3994
325,7269
321,7975
321,1522
2756,1920
4802,3181
5099,2706
2376,3241
2429,6772
Tabel 2.11 Hasil Perhitungan Kecepatan Perpindahan Panas Cold Fluid pada Concentric Counter Current
No,
Cold Flow
(ft3/jam)
TC1
(oF)
TC2
(oF)
TC avg
(oF)
1
2
3
4
5
0,0034
0,0031
0,0028
0,0025
0,0022
68,36
86,72
86,36
84,2
86,36
102,74
102,74
101,3
92,12
93,74
85,55
94,73
93,83
88,16
90,05
(lb/ft3)
62,1647
62,1306
62,1603
62,0571
62,1121
Cp
( Btu/lb oF)
0,9986
0,9986
0,9986
0,9986
0,9986
mc
(lb/jam)
447,8438
408,1046
368,7866
328,7269
289,5363
qc
(Btu/jam)
15375,3451
6530,2254
5501,9037
2599,8464
2133,7653
Tabel 2.12 Hasil Perhitungan Koefisien Perpindahan Panas Overall pada Concentric Counter Current
No
,
1
LMTD
(oF)
Uo
(Btu /jam ft2 oF)
Ui
(Btu /jam ft2 oF)
Um
(Btu /jam ft2 oF)
44,4680
91,6921
292,5280
64,3905
42,5669
166,8973
68,2580
117,2031
39,7789
189,6380
50,6130
133,1728
60,7496
57,8672
78,3772
40,6371
60,5700
59,3419
62,7277
41,6727
Tabel 2.13 Hasil Perhitungan Keefektifan Heat Exchanger pada Concentric Counter Current
No
,
(mxCp)hot
(Btu/jam oF)
(mxCp)cold
(Btu/jam oF)
(mxCp)min
(Btu/jam oF)
Q actual
(Btu/jam)
Thavg - Tcavg
(oF)
Keefektifan ()
325,7910
447,2177
325,7910
15375,3451
67,1400
0,7029
325,3603
407,6296
325,3603
4802,3181
57,9600
0,2547
325,6239
368,2666
325,6239
5099,2706
55,0800
0,2843
321,9951
328,2634
321,9951
2376,3241
68,4000
0,1079
321,3859
289,1281
289,1281
2133,7653
68,0400
0,1085
Rf
(jam ft2 oF/Btu)
0,0013
Tabel 2.14 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Batch Operation 0 rpm Hot Fluid
Time
(s)
0
1
2
3
4
5
Flowrate
(ft3/jam)
5,297
TH1
(oF)
TH2
(oF)
THavg
(oF)
154,22
163,76
144,32
145,04
145,76
136,04
154,58
176,72
156,74
139,82
152,78
160,52
154,4
170,24
150,53
142,43
149,27
148,28
(lb/ft3)
61,0840
60,7794
61,1645
60,6827
60,9084
61,2450
Cp
( Btu/lb oF)
1,0010
1,0024
1,0007
1,0002
1,0006
1,0005
mh
(lb/jam)
qh
(Btu/jam)
323,5626
321,9492
323,9892
321,4369
322,6325
324,4152
-116,5965
-4182,2846
-4026,8499
1678,2099
-2266,3251
-7945,3575
Tabel 2.15 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Batch Operation 0 rpm Cold Fluid
Time(s)
0
1
2
3
4
5
Volume (ft3)
TC5
(oF)
(lb/ft3)
0,0777
91,94
100,76
103,784
109,94
113,9
119,84
62,1401
62,1101
62,0999
62,0035
61,8990
61,7422
Cp
( Btu/lb
o
F)
0,9989
0,9987
0,9986
0,9987
0,9989
0,9990
mc
(lb/jam)
TC5n-TC5n-1
(oF)
qc
(Btu/jam)
4,8283
4,8260
4,8252
4,8177
4,8096
4,7974
8,82
3,02
6,16
3,96
5,94
8,82
2552,3445
874,4624
1779,7180
1143,2457
1712,1580
Tabel 2.16 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Batch Operation 300 rpm Hot Fluid
Time
(s)
0
1
2
3
4
5
Flowrate
(ft3/jam)
5,297
TH1
(oF)
TH2
(oF)
THavg
(oF)
142,52
154,4
157,1
169,16
163,94
141,08
149
138,56
150,98
173,48
157,64
140,18
145,76
146,48
154,04
171,32
160,79
140,63
(lb/ft3)
61,2638
61,2488
61,0915
60,7592
60,9510
61,3706
Cp
( Btu/lb oF)
1,0072
1,0069
1,0032
1,0025
0,9998
1,0097
mh
(lb/jam)
Qh
(Btu/jam)
324,5150
324,4356
323,6023
321,8419
322,8582
325,0805
-2118,0535
5174,3813
1986,7071
-1393,7695
2033,6967
295,4236
Tabel 2.17 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Batch Operation 300 rpm Cold Fluid
Time
(s)
0
1
2
3
4
5
Volume (ft3/jam)
TC5
(oF)
0,0777
126,68
132,62
136,94
107,78
85,64
86,54
(lb/ft3)
61,9783
61,9697
61,9279
61,8783
Cp
( Btu/lb oF)
0,9991
0,9991
0,9992
0,9992
61,9890
61,9804
0,9991
0,9991
mc
(lb/jam)
TC5n-TC5n-1
(oF)
qc
(Btu/jam)
4,8157
4,8150
4,8118
4,8079
4,8165
4,8159
5,94
4,32
-29,16
-22,14
0,90
5,94
116883,5377
84954,9329
-573014,0671
-435781,8905
17712,2632
Tabel 2.18 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Continuous Operation 0 rpm Hot Fluid
Time
(s)
0
1
2
3
4
5
Flowrate
(ft3/jam)
qh
(Btu/jam)
mh
(lb/jam)
5,297
232,2991
9123,4044
3776,4654
-173,7881
7926,5617
1846,7582
321,8316
319,1615
322,0194
320,6792
320,0997
318,8853
(lb/ft3)
60,7572
60,2531
60,7927
60,5397
60,4303
60,2010
Cp
(Btu/lb oF)
1,0025
1,0051
1,0023
1,0036
1,0042
1,0054
TH1
(oF)
TH2
(oF)
TH avg
(oF)
172,22
208,76
176
181,58
199,04
199,58
171,5
180,32
164,3
182,12
174,38
193,82
171,86
194,54
170,15
181,85
186,71
196,7
Tabel 2.19 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Continuous Operation 0 rpm Cold Fluid
Time
(s)
0
1
2
3
4
5
Flowrate
(ft3/jam
TC1
(oF)
TC4
(oF)
TCavg
(oF)
5,297
68,36
69,08
77,36
86,36
89,96
86,72
75,92
86,18
80,06
102,02
89,78
98,24
72,14
77,63
78,71
94,19
89,87
92,48
(lb/ft3)
62,2865
62,2416
62,2311
62,0629
62,1143
62,0832
Cp
(Btu/lb oF)
0,9992
0,9988
0,9988
0,9986
0,9986
0,9986
mc
(lb/jam)
qc
(Btu/jam)
329,9321
329,6943
329,6387
328,7476
329,0199
328,8554
2492,3305
5631,0758
888,9419
5140,9294
-59,1401
3783,0727
Tabel 2.20 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Continuous Operation 300 rpm Hot Fluid
Time
(s)
0
1
2
3
4
5
Flowrate
(ft3/jam)
qh
(Btu/jam)
mh
(lb/jam)
5,297
-14616,4743
4494,8696
3732,6754
5155,5740
6998,8621
16722,4072
309,0519
324,0636
313,5320
321,6274
321,1195
315,4368
(lb/ft3)
58,3446
61,1786
59,1904
60,7187
60,6228
59,5500
Cp
(Btu/lb oF)
1,0029
1,0007
1,0021
1,0006
1,0007
1,0018
TH1
(oF)
TH2
(oF)
TH avg
(oF)
159,08
157,82
177,62
156,74
161,06
192,74
206,24
143,96
165,74
140,72
139,28
139,82
182,66
150,89
171,68
148,73
150,17
166,28
Tabel 2.21 Hasil Perhitungan Kecepatan Transfer Panas pada Jacket Continuous Operation 300 rpm Cold Fluid
Time
(s)
0
1
2
3
4
5
Flowrate
(ft3/jam)
TC1
(oF)
TC4
(oF)
TCavg
(oF)
5,297
77,36
87,8
96,26
87,62
91,4
90,14
100,4
87,62
100,22
100,22
86,9
88,52
88,88
87,71
98,24
93,92
89,15
89,33
(lb/ft3)
62,1260
62,1400
62,0147
62,0661
62,1228
62,1207
Cp
(Btu/lb oF)
0,9986
mc
(lb/jam)
qc
(Btu/jam)
329,0823
329,1560
328,4924
328,7647
329,0652
329,0539
7571,3649
-59,1645
1298,9959
4136,5941
-1478,7057
-532,3157
Tabel 2.22 Hasil Perhitungan Keefektifan Jacket Batch Operation 0 dan 300 rpm
Time
(s)
0 rpm
Flowrate
(ft3/jam)
0
1
2
3
4
5
5,297
300 rpm
TH1
TH2
TC5
154,22
163,76
144,32
145,04
145,76
136,04
154,58
176,72
156,74
139,82
152,78
160,52
91,94
100,76
103,784
109,94
113,9
119,84
0,8772
0,7739
0,6610
0,5920
0,3673
TH1
TH2
142,52
154,4
157,1
169,16
163,94
141,08
149
138,56
150,98
173,48
157,64
140,18
161,5913
155,2995
150,9283
157,1931
142,6581
144,4120
86,54
0,7857
0,6627
1,4449
2,1014
3,7875
(m x Cp)cold
(Btu/jam oF)
(m x Cp)min
(Btu/jam oF)
q act
(Btu/jam)
Keefektifan ()
322,6376
320,7948
322,7748
321,8297
321,4340
320,6177
329,6733
329,3027
329,2377
328,2841
328,5560
328,3917
322,637634
320,79481
322,774825
321,829741
321,433969
320,617737
232,2991
5631,0758
888,9419
-173,7881
-59,1401
1846,7582
96,30
122,58
95,94
79,56
109,26
101,34
0,0075
0,1432
0,0287
-0,0068
-0,0017
0,0568
hj
(Btu/hr ft2 F)
161,5913
155,2995
150,9283
157,1931
142,6581
144,4120
Tabel 2.25 Hasil Perhitungan Keefektifan Jacket Continuous Operation 300 rpm
(m x Cp)Hot
(Btu/jam oF)
(m x Cp)cold
(Btu/jam oF)
(m x Cp)min
(Btu/jam oF)
q act
(Btu/jam)
TH1 - TC4
(oF)
Keefektifan ()
hj
(Btu/hr ft2 F)
309,9337
324,3052
314,1983
321,8211
321,3435
315,9941
328,6183
328,6919
328,0293
328,3011
328,6013
328,5899
309,933722
324,305169
314,198263
321,821102
321,343531
315,99409
-14616,4743
-59,1645
1298,9959
4136,5941
-1478,7057
-532,3157
58,68
70,20
77,40
56,52
74,16
104,22
-0,8037
-0,0026
0,0534
0,2274
-0,0621
-0,0162
202,2869
189,8037
197,9147
187,5175
188,2025
195,5458