VALVE MATRIX
TYPE
SAFETY VALVES
CLASS I
KELLY VALVES
X
X
X
X
X
X
CLASS II
KELLY VALVES
Headquarters: 12300 S. Main (77035) - P.O. Box 35729 (77235-5729) - Houston, Texas - Tel 713-729-2110
www.tiwtools.com
Headquarters: 12300 S. Main (77035) - P.O. Box 35729 (77235-5729) - Houston, Texas - Tel 713-729-2110
www.tiwtools.com
Headquarters: 12300 S. Main (77035) - P.O. Box 35729 (77235-5729) - Houston, Texas - Tel 713-729-2110
www.tiwtools.com
High torque middle connection Double lead threadflat shoulder (no angle) (Class II only)
Radius seat w/seal ring (Class II only)
Bottom Locate control (Class II only)
Control ORing positioned for external pressure (Class II only)
Modified lower seat for corrugated spring optimum deflection and double step (Class II)
Stem 2,000 psi externallow pressure 250 psi (Stem test performed once, for each valve design, not for
each valve manufactured) (Class II)
Top seat 250 psi low pressuremax. working pressure (Class II)
Bottom seat 250 psi max. working pressure (Class I & II)
Valve shell test Test pressure (Class I & II)
3. Seals will be tested @ 14 deg F and 194 deg F with test fluid as per test procedure as per 4.5.2 and 4.5.3
(once for each valve design, not for each valve manufactured) (Class II only)
4. Testing:
A.
Shell testing: Both ends caped with Ball half closed. Both the low pressure and high pressure test shall
be conducted in three parts. (low pressure 250 psi)(high pressuretest rating of valve) (Applies to
both Class I & II)
a. Initial pressure holding period for 3 minutes
b. Reduction of pressure to zero
c. Final pressure 10 minutes minimum
B. Working pressure test: Test period shall be for a minimum of 5 minutes
a. Pressure from belowLow pressure 250 psihigh pressure shall be working pressure of valve
(Applies to both Class I & II)
b. Pressure from aboveLow pressure 250 psihigh pressure shall be working pressure of valve
(Class II only)
5. Marking: (Class I & II)
A. Low Stress Stamp
All of B will be placed in mill recess
B. Manufacture name or Mark (logo)
Class of service (type I or II)
Serial Number
Date of manufacture (year/month)
Maximum working pressure
C. Connection Size and style on O.D. surface adjacent to connection
D. Indication of Rotation direction required to position valve in closed position.
E. Indication of mud flow shall be marked on Class I valves with and arrow (
) and word flow
6. NDT Testing: (Class I & II)
A. End connections and any service connections shall be non-destructively inspected by the wet
magnetic particle method for both transverse and longitudinal defects in accordance with ASTM E709.
7. Materials:
A. Materials will not change as per TIW specifications for both Class I & II.