SR-1000
SIEMENS S7-1200 SERIES
Chapter
Table of Contents
Chapter
SR-1000 Series
EQUIPMENT USED
USB cable
Code Reader
SR-1000 Series
Control cable
OP-87224 (2 m)
SB cable
OP-51580 (2 m)
Chapter
CONNECTION METHODS
Ethernet hub
S7-1200 Series
Ethernet cable
Control cable
Brown
0V
Blue
24 VDC
power supply
SR-1000
SIEMENS S7-1200 SERIES
Chapter
Start TIA Portal, and then click Project view in the lower left of
the screen.
Click the new project button
to display the Create a new project
screen. Enter a project name, and then click Create.
Double-click Add new device under the new project that has been
added to the Project tree.
On the Add new device screen, click the S7-1200 Series that you will
use, and then click OK. (You can specify an arbitrary value for
Device name. Here, we have used PLC_1.)
Click the Start the setup wizard, and set as shown below.
Open the Online access branch in the Project tree, and then click
the network card of the PC that the S7-1200 Series is connected to.
Double-click Update accessible devices to automatically scan for
and display the devices that can be accessed from the selected
network card.
* If a firewall is enabled, the scan may not be performed correctly. In this situation,
temporarily disable the firewall.
Setting Item
Data handshake
Device name
Setting Value
Disabled
sr-1000
SR-1000
SIEMENS S7-1200 SERIES
* If the PLC has already been set, you may not be able to assign the IP address. In
this situation, click Reset to factory settings to return the PLC to its factory default
status, and then return to step 2 of this procedure.
In the Hardware catalog field, click Other field devices, PROFINET IO,
Sensors, KEYENCE CORPORATION, Keyence Code Readers,
and then check that SR-1000X is selectable.
64-bit version:
C:\Program Files (x86)\KEYENCE Applications\AutoID\GSDML
\SR-1000
32-bit version:
C:\Program Files\KEYENCE Applications\AutoID\GSDML
\SR-1000
On the Options menu, click Install general station description file
(GSD).
Specify the folder that contains the GSDML file for the Source path.
Select the check box of the corresponding GSDML file, and then click
Install.
In the Devices & networks field, click the Network view tab, and
then drag SR-1000X from the catalogue to this tab.
After the GSDML file is read, you will be prompted to restart, so save
the project, and then restart the setup software.
Click Project view in the lower left of the screen, and then click
Open on the Project menu.
Click on a project, and then click Open.
After the Open existing project screen is displayed, click a project,
and then click Open.
SR-1000
SIEMENS S7-1200 SERIES
Click the green box in the upper left of the SR-1000X to create a line,
and then extend this line to the green box in the lower left of the PLC.
Under Advanced options, click IO cycle, and then set Update time
to 64.000 ms and Accepted update cycles without IO data to 16.
* Adjust these parameters to match your operation environment.
Click the Network view tab, and then double-click the PLC image.
On the General tab, click Profinet interface, click Ethernet addresses,
and then set the IP address of the PLC.
Click the Network view tab, right-click the PLC, point to Compile,
and then click All to execute the compilation.
Double-click the SR-1000X image, click the General tab, click
PROFINET interface, click Ethernet addresses, and then set the IP
address of the SR-1000X.
Right-click
here.
* If you attempt to specify the IP address that belongs to the PLC that you will set
later, the warning The IP address is not unique within the subnet. will be displayed.
Change the address of the PLC or SR.
* If the IP address that you set for the SR-1000 on this screen is different from the IP
address that you set with AutoID Network Navigator, the IP address will be forcibly
changed to the one that you set here.
SR-1000
SIEMENS S7-1200 SERIES
Chapter
Module names
15 14 13 12 11 10 9
15 14 13 12 11 10 9
Result Data
B294
SR-1000
SIEMENS S7-1200 SERIES
Right-click
here.
Tag table_1 is added. Enter the arbitrary names of the data in the
Name column, the data types in the Data type column, and the
device addresses in the Address column.
You can download the Tag Description CSV file on the WEB
(barcodereader.com).
Please copy the CSV file data and paste Tag table.(Before copy and
paste, please fit the column between CSV file and your Tag table.)
Explanation
SR-1000
SIEMENS S7-1200 SERIES
Chapter
Click Watch and force tables, and then double-click Add new watch
table.
In Watch table_1, enter the tag names registered to PLC tags in the
Name column. For each reading result (Result Data) entry, change
the value in the Display format column to Character. (When you
write a name registered to PLC tags in the Name column, the data
is written to the other columns automatically. You can also copy data
from the Tag Table.)
2
Click
SR-1000
SIEMENS S7-1200 SERIES
Sample code
KEYENCE
In the Watch table, right-click the value in the Monitor value column
for Start Ladder Bit, point to Modify, and then click Modify to 1 to
start reading.
Right-click
here.
When the sample code is read, the data read is stored in the Result
Data area as shown below. Also, you can check whether reading is
complete by checking whether Read Complete has changed to
TRUE.
Please visit:
SAFETY INFORMATION
www.keyence.com
KEYENCE CORPORATION
AUSTRIA
Phone: +43 22 36-3782 66-0
CZECH REPUBLIC
Phone: +420 222 191 483
INDIA
Phone: +91-44-4963-0900
MALAYSIA
Phone: +60-3-2092-2211
SINGAPORE
Phone: +65-6392-1011
THAILAND
Phone: +66-2-369-2777
BELGIUM
Phone: +32 1 528 1222
FRANCE
Phone: +33 1 56 37 78 00
INDONESIA
Phone: +62-21-2966-0120
MEXICO
Phone: +52-55-8850-0100
SLOVAKIA
Phone: +421 2 5939 6461
UK & IRELAND
Phone: +44-1908-696900
BRAZIL
Phone: +55-11-3045-4011
GERMANY
Phone: +49 61 02 36 89-0
ITALY
Phone: +39-02-6688220
NETHERLANDS
Phone: +31 40 20 66 100
SLOVENIA
Phone: +386 1-4701-666
USA
Phone: +1-201-930-0100
CANADA
Phone: +1-905-366-7655
HONG KONG
Phone: +852-3104-1010
JAPAN
Phone: +81-6-6379-2211
POLAND
Phone: +48 71 36861 60
SWITZERLAND
Phone: +41 43-45577 30
VIETNAM
Phone: +84-4-3760-6214
CHINA
Phone: +86-21-68757500
HUNGARY
Phone: +36 1 802 73 60
KOREA
Phone: +82-31-789-4300
ROMANIA
Phone: +40 269-232-808
TAIWAN
Phone: +886-2-2718-8700
WW1-1065
The information in this publication is based on KEYENCEs internal research/evaluation at the time of release and is subject to change without notice.
Company and product names mentioned in this catalogue are trademarks or registered trademarks of their respective companies.
PLCConS712SR1000-WW-EN-GB 1114-2 600F51 Printed in Japan
Copyright (c) 2014 KEYENCE CORPORATION. All rights reserved.