CALCULATION NOTE FOR

MODULARIZED PIPERACK
(PAR-60104-9~16) (IN-PLACE ANALYSIS)

AD204-601-G-03362 (Rev 1)

MOD - 13
8.1(A) Base Plate & Anchor Bolt Design (W14X120)
8.1(A).1 Column Base Plate
Maximum column reactions are as follows;

Unit : kN, m
member

Load

Joint No. Load Comb

W14x120_B_M42

Max C

Max T

Max V

214

Actual loads
Moment(Mx) Moment(Mz)

Shear(Fx)

Axial(Fy)

Shear(Fz)

214

5.425

944.156

103.322

364.422

204

0.124

-3.061

78.945

271.277

0.308

8.092

390.034

131.991

469.136

27.832

21.991

Max M

214

8.092

390.034

131.991

469.136

27.832

Max M

221

-13.859

622.075

-15.695

72.572

49.887

Note: C: Compression
T: Tension
M: Moment
V: Shear

Column Joint Number

9
7
10

5
8

3
1

6
4

2
X
Z

Joint Number
5, 6

Translation

Rotation

Remark
1: Fixed

0: Free

1.0 BASE PLATE HOLE CHECK (MPR 13)


1.1 SECTION W14x120

1) DESIGN CONDITION
(1) Material
- BASE PLATE :
250 Mpa
Fy=
Fu=
- ANCHOR Bolt : F1554 Gr36
250 MPa,
Fy=
Fu=

400

Mpa

420

Mpa

(2) Member
- Level Pt : 780 x 670 x 80 (Unit: mm)
A
B
D
E
F
780.0
670.0
55.0
170.0
165.0
- Anchor Bolt : M 42
- Base Plate thickness, tg
tg = 80 mm

2) BASE PLATE CHECK


(1) Design Load
Shear(kN), Va = 132.0

kN

- Col :
H
367.8

W14x120
B
tw
372.6
15.0

tf
23.9

(Unit: mm)
r
15.2

ANCHOR BOLT

Bp

Y
Z

XX
0
dt

dt

h
D
Dp

db
42

Hole Dia.
52

B
670.0

tg
80.0

Ag
53600.0

Ae
41120.0

Anv
41120.0

where, db = nominal bolt diameter, (mm)


Ag = gross area of member, (mm2) = B x tg
Ae = effective net area, (mm2) = (B - N x Bolt Hole Dia.) x tg
Anv = net area subject to shear, (mm2)
B = depth of plate used, (mm)
(1) Available Bearing Strength

2.00

Rn/ = 1.2LctgFu/ 2.4dbtgFu/


348 kN
1612.8 kN
348 kN
Rn/ =
<

where, Lc = clear distance , between edge of the hole and edge of the materia 29.0 mm

(Eq.J3-6a)

(2) Shear Strength


- For Shear yielding
Rn/ = 0.6FyAg/ =
- For Shear Rupture
Rn/ = 0.6FuAnv/ =

1.50

=
536.0

kN

493.4

kN

>

Va =
2.00

132

kN

-- OK

(Eq.J4-3)

>

Va =

132

kN

-- OK

(Eq.J4-4)

3) BLOCK SHEAR STRENGTH

2.00

Ubs = 1.00

by Shear Force
(1) by Shear Force
Rn/ =(0.6FuAnv+UbsFuAnt)/ (0.6FyAgv+UbsFuAnt)/
2729.6 kN
2192 kN
Rn/ =
>
2192 kN
23040.0 mm2
where, Agv = gross area subjected to shear = (B-2F-Hole Dia) tg =
2320.0 mm2
Ant = net area subjected to tension = (D-Bolt Hole Dia./2) tg =
18880.0 mm2
Anv = net area subjected to shear = (2 x E-2 x Hole Dia) x tg=
where the tension stress is uniform, Ubs = 1.0 ; where the tension stress is nonuniform, Ubs = 0.5
Rn/ =

2192.0 kN

>

Va =

132.0

kN

(Eq.J4-5)

-- OK

by Shear Force
(2) by Shear Force
Rn/ =(0.6FuAnv+UbsFuAnt)/ (0.6FyAgv+UbsFuAnt)/
1798.4 kN
1298 kN
Rn/ =
>
1298 kN
11120.0 mm2
where, Agv = gross area subjected to shear = (F-Hole Dia/2) tg =
2320.0 mm2
Ant = net area subjected to tension = (D-Bolt Hole Dia./2) tg =
11120.0
Anv = net area subjected to shear = (F-Hole Dia/2) x tg=
mm2
where the tension stress is uniform, Ubs = 1.0 ; where the tension stress is nonuniform, Ubs = 0.5
Rn/ =

1298.0 kN

>

Va =

132.0

kN

-- OK

(Eq.J4-5)

CALCULATION NOTE FOR


MODULARIZED PIPERACK
(PAR-60104-9~16) (IN-PLACE ANALYSIS)

AD204-601-G-03362 (Rev 1)

MOD - 14
8.1(A) Base Plate & Anchor Bolt Design (W14X120)
8.1(A).1 Column Base Plate
Maximum column reactions are as follows;

Unit : kN, m
Joint No. Load Comb

member

Load

W14x120_B_M42

Max C

30

Max T

Actual loads
Shear(Fx)

Axial(Fy)

Shear(Fz) Moment(Mx) Moment(Mz)

213

-9.519

1157.542

-136.098

510.233

31

203

-0.028

-92.641

-87.060

294.852

0.248

Max V

32

214

15.356

438.475

159.923

549.882

54.160

Max M

32

214

15.356

438.475

159.923

549.882

54.160

Max M

31

211

-21.288

476.187

-29.465

109.731

75.983

38.607

Note: C: Compression
T: Tension
M: Moment
V: Shear

Column Joint Number

31
29
32

27
25

30

23

28

21

26
24

Y
X
Z

Joint Number
29 to 32

22

Translation

Rotation

Remark
1: Fixed

0: Free

1.0 BASE PLATE HOLE CHECK (MPR 14)


1.1 SECTION W14x120

1) DESIGN CONDITION
(1) Material
- BASE PLATE :
250 Mpa
Fy=
Fu=
- ANCHOR Bolt : F1554 Gr36
250 MPa,
Fy=
Fu=

400

Mpa

420

Mpa

(2) Member
- Level Pt : 780 x 670 x 80 (Unit: mm)
A
B
D
E
F
780.0
670.0
55.0
170.0
165.0
- Anchor Bolt : M 42
- Base Plate thickness, tg
tg = 80 mm

2) BASE PLATE CHECK


(1) Design Load
Shear(kN), Va = 159.9

kN

- Col :
H
367.8

W14x120
B
tw
372.6
15.0

tf
23.9

(Unit: mm)
r
15.2

ANCHOR BOLT

Bp

Y
Z

XX
0
dt

dt

h
D
Dp

db
42

Hole Dia.
52

B
670.0

tg
80.0

Ag
53600.0

Ae
41120.0

Anv
41120.0

where, db = nominal bolt diameter, (mm)


Ag = gross area of member, (mm2) = B x tg
Ae = effective net area, (mm2) = (B - N x Bolt Hole Dia.) x tg
Anv = net area subject to shear, (mm2)
B = depth of plate used, (mm)
(1) Available Bearing Strength

2.00

Rn/ = 1.2LctgFu/ 2.4dbtgFu/


348 kN
1612.8 kN
348 kN
Rn/ =
<

where, Lc = clear distance , between edge of the hole and edge of the materia 29.0 mm

(Eq.J3-6a)

(2) Shear Strength


- For Shear yielding
Rn/ = 0.6FyAg/ =
- For Shear Rupture
Rn/ = 0.6FuAnv/ =

1.50

=
536.0

kN

493.4

kN

>

Va =
2.00

>

Va =

160

kN

-- OK

(Eq.J4-3)

159.9

kN

-- OK

(Eq.J4-4)

3) BLOCK SHEAR STRENGTH

2.00

Ubs = 1.00

by Shear Force
(1) by Shear Force
Rn/ =(0.6FuAnv+UbsFuAnt)/ (0.6FyAgv+UbsFuAnt)/
2729.6 kN
2192 kN
Rn/ =
>
2192 kN
23040.0 mm2
where, Agv = gross area subjected to shear = (B-2F-Hole Dia) tg =
2320.0 mm2
Ant = net area subjected to tension = (D-Bolt Hole Dia./2) tg =
18880.0 mm2
Anv = net area subjected to shear = (2 x E-2 x Hole Dia) x tg=
where the tension stress is uniform, Ubs = 1.0 ; where the tension stress is nonuniform, Ubs = 0.5
Rn/ =

2192.0 kN

>

Va =

159.9

kN

(Eq.J4-5)

-- OK

by Shear Force
(2) by Shear Force
Rn/ =(0.6FuAnv+UbsFuAnt)/ (0.6FyAgv+UbsFuAnt)/
1798.4 kN
1298 kN
Rn/ =
>
1298 kN
11120.0 mm2
where, Agv = gross area subjected to shear = (F-Hole Dia/2) tg =
2320.0 mm2
Ant = net area subjected to tension = (D-Bolt Hole Dia./2) tg =
11120.0
Anv = net area subjected to shear = (F-Hole Dia/2) x tg=
mm2
where the tension stress is uniform, Ubs = 1.0 ; where the tension stress is nonuniform, Ubs = 0.5
Rn/ =

1298.0 kN

>

Va =

159.9

kN

-- OK

(Eq.J4-5)

CALCULATION NOTE FOR


MODULARIZED PIPERACK
(PAR-60104-9~16) (IN-PLACE ANALYSIS)

AD204-601-G-03362 (Rev 1)

MOD - 15
8.1(A) Base Plate & Anchor Bolt Design (W14X120)
8.1(A).1 Column Base Plate
Maximum column reactions are as follows;

Unit : kN, m
member

Load

W14x120_B_M42

Actual loads

Joint No. Load Comb


Shear(Fx)

Axial(Fy)

Shear(Fz) Moment(Mx) Moment(Mz)

Max C

17

212

135.789

1073.773

11.193

50.192

10.173

Max T

20

212

218.552

-233.983

32.773

118.161

39.056

Max V

19

211

-307.896

903.156

-14.362

63.401

40.815

Max M

16

214

-3.588

203.124

104.177

448.366

16.174

Max M

19

211

-307.896

903.156

-14.362

63.401

40.815

Note: C: Compression
T: Tension
M: Moment
V: Shear

Column Joint Number

19

17

20
15
18
13

16
Y
X
Z

Joint Number
15 to 20

14

Translation

Rotation

Remark
1: Fixed

0: Free

1.0 BASE PLATE HOLE CHECK (MPR 15)


1.1 SECTION W14x120

1) DESIGN CONDITION
(1) Material
- BASE PLATE :
250 Mpa
Fy=
Fu=
- ANCHOR Bolt : F1554 Gr36
250 MPa,
Fy=
Fu=

400

Mpa

420

Mpa

(2) Member
- Level Pt : 780 x 670 x 80 (Unit: mm)
A
B
D
E
F
780.0
670.0
55.0
170.0
165.0
- Anchor Bolt : M 42
- Base Plate thickness, tg
tg = 80 mm

2) BASE PLATE CHECK


(1) Design Load
Shear(kN), Va = 104.2

kN

- Col :
H
367.8

W14x120
B
tw
372.6
15.0

tf
23.9

(Unit: mm)
r
15.2

ANCHOR BOLT

Bp

Y
Z

XX
0
dt

dt

h
D
Dp

db
42

Hole Dia.
52

B
670.0

tg
80.0

Ag
53600.0

Ae
41120.0

Anv
41120.0

where, db = nominal bolt diameter, (mm)


Ag = gross area of member, (mm2) = B x tg
Ae = effective net area, (mm2) = (B - N x Bolt Hole Dia.) x tg
Anv = net area subject to shear, (mm2)
B = depth of plate used, (mm)
(1) Available Bearing Strength

2.00

Rn/ = 1.2LctgFu/ 2.4dbtgFu/


348 kN
1612.8 kN
348 kN
Rn/ =
<

where, Lc = clear distance , between edge of the hole and edge of the materia 29.0 mm

(Eq.J3-6a)

(2) Shear Strength


- For Shear yielding
Rn/ = 0.6FyAg/ =
- For Shear Rupture
Rn/ = 0.6FuAnv/ =

1.50

=
536.0

kN

493.4

kN

>

Va =
2.00

>

Va =

104

kN

-- OK

(Eq.J4-3)

104.17 kN

-- OK

(Eq.J4-4)

3) BLOCK SHEAR STRENGTH

2.00

Ubs = 1.00

by Shear Force
(1) by Shear Force
Rn/ =(0.6FuAnv+UbsFuAnt)/ (0.6FyAgv+UbsFuAnt)/
2729.6 kN
2192 kN
Rn/ =
>
2192 kN
23040.0 mm2
where, Agv = gross area subjected to shear = (B-2F-Hole Dia) tg =
2320.0 mm2
Ant = net area subjected to tension = (D-Bolt Hole Dia./2) tg =
18880.0 mm2
Anv = net area subjected to shear = (2 x E-2 x Hole Dia) x tg=
where the tension stress is uniform, Ubs = 1.0 ; where the tension stress is nonuniform, Ubs = 0.5
Rn/ =

2192.0 kN

>

Va =

104.2

kN

(Eq.J4-5)

-- OK

by Shear Force
(2) by Shear Force
Rn/ =(0.6FuAnv+UbsFuAnt)/ (0.6FyAgv+UbsFuAnt)/
1798.4 kN
1298 kN
Rn/ =
>
1298 kN
11120.0 mm2
where, Agv = gross area subjected to shear = (F-Hole Dia/2) tg =
2320.0 mm2
Ant = net area subjected to tension = (D-Bolt Hole Dia./2) tg =
11120.0
Anv = net area subjected to shear = (F-Hole Dia/2) x tg=
mm2
where the tension stress is uniform, Ubs = 1.0 ; where the tension stress is nonuniform, Ubs = 0.5
Rn/ =

1298.0 kN

>

Va =

104.2

kN

-- OK

(Eq.J4-5)

CALCULATION NOTE FOR


MODULARIZED PIPERACK
(PAR-60104-9~16) (IN-PLACE ANALYSIS)

AD204-601-G-03362 (Rev 1)

MOD - 16
8.1(A) Base Plate & Anchor Bolt Design (W14X90)
8.1(A).1 Column Base Plate
Maximum column reactions are as follows;

Unit : kN, m

member

Load

Joint No. Load Comb

W14x90_B_M42

Max C

Max T

Actual loads
Shear(Fz) Moment(Mx) Moment(Mz)

Shear(Fx)

Axial(Fy)

212

213.345

1110.727

11.734

52.794

211

-127.899

-385.314

-18.667

62.490

7.342

Max V

211

-306.541

992.515

-13.914

62.510

29.652

Max M

214

10.504

200.154

81.112

296.569

28.835

Max M

11

211

-13.636

333.364

-9.138

42.814

50.045

5.581

Note: C: Compression
T: Tension
M: Moment
V: Shear

Column Joint Number

11
9
7

12

10
8

3
6

1
4
Y

X
Z

Joint Number
1 to 12

Load 1

Translation

Rotation

Remark
1: Fixed

0: Free

1.0 BASE PLATE HOLE CHECK (MPR 16)


1.1 SECTION W14x90

1) DESIGN CONDITION
(1) Material
- BASE PLATE :
250 Mpa
Fy=
Fu=
- ANCHOR Bolt : F1554 Gr36
250 MPa,
Fy=
Fu=

400

Mpa

420

Mpa

(2) Member
- Level Pt : 760 x 650 x 75 (Unit: mm)
A
B
D
E
F
760.0
650.0
55.0
170.0
155.0
- Anchor Bolt : M 42
- Base Plate thickness, tg
tg = 75 mm

2) BASE PLATE CHECK


(1) Design Load
Shear(kN), Va = 81.1

kN

- Col :
H
356.1

W14x90
B
tw
368.8
11.2

tf
18.0

(Unit: mm)
r
15.2

ANCHOR BOLT

Bp

Y
Z

XX
0
dt

dt

h
D
Dp

db
42

Hole Dia.
52

B
650.0

tg
75.0

Ag
48750.0

Ae
37050.0

Anv
37050.0

where, db = nominal bolt diameter, (mm)


Ag = gross area of member, (mm2) = B x tg
Ae = effective net area, (mm2) = (B - N x Bolt Hole Dia.) x tg
Anv = net area subject to shear, (mm2)
B = depth of plate used, (mm)
(1) Available Bearing Strength

2.00

Rn/ = 1.2LctgFu/ 2.4dbtgFu/


326.25 kN
1512 kN
326 kN
Rn/ =
<

where, Lc = clear distance , between edge of the hole and edge of the materia 29.0 mm

(Eq.J3-6a)

(2) Shear Strength


- For Shear yielding
Rn/ = 0.6FyAg/ =
- For Shear Rupture
Rn/ = 0.6FuAnv/ =

1.50

=
487.5

kN

444.6

kN

>

Va =
2.00

>

Va =

81

kN

-- OK

(Eq.J4-3)

81.1

kN

-- OK

(Eq.J4-4)

3) BLOCK SHEAR STRENGTH

2.00

Ubs = 1.00

by Shear Force
(1) by Shear Force
Rn/ =(0.6FuAnv+UbsFuAnt)/ (0.6FyAgv+UbsFuAnt)/
2559 kN
2055 kN
Rn/ =
>
2055 kN
21600.0 mm2
where, Agv = gross area subjected to shear = (B-2F-Hole Dia) tg =
2175.0 mm2
Ant = net area subjected to tension = (D-Bolt Hole Dia./2) tg =
17700.0 mm2
Anv = net area subjected to shear = (2 x E-2 x Hole Dia) x tg=
where the tension stress is uniform, Ubs = 1.0 ; where the tension stress is nonuniform, Ubs = 0.5
Rn/ =

2055.0 kN

>

Va =

81.1

kN

(Eq.J4-5)

-- OK

by Shear Force
(2) by Shear Force
Rn/ =(0.6FuAnv+UbsFuAnt)/ (0.6FyAgv+UbsFuAnt)/
1596 kN
Rn/ =
> 1160.63 kN
1160.63 kN
9675.0 mm2
where, Agv = gross area subjected to shear = (F-Hole Dia/2) tg =
2175.0 mm2
Ant = net area subjected to tension = (D-Bolt Hole Dia./2) tg =
9675.0 mm2
Anv = net area subjected to shear = (F-Hole Dia/2) x tg=
where the tension stress is uniform, Ubs = 1.0 ; where the tension stress is nonuniform, Ubs = 0.5
Rn/ =

1160.6 kN

>

Va =

81.1

kN

-- OK

(Eq.J4-5)