DESIGN MANUAL

SEM - 3036E
Piping Design Manual
RACK PIPING
REV. : 5
DATE : 1998.

9. 28

SAMSUNG ENGINEERING CO., LTD.

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

OF

CONTENTS
Page
1. GENERAL
1.1

Purpose ------------------------------------------------------------------------------ 1

1.2

Application Scope -------------------------------------------------------------------- 1

1.3

Relevant Manuals --------------------------------------------------------------------- 1

2. PIPING DESIGN CRITERIA


2.1 Rack piping design criteria ----------------------------------------------------------- 1
2.2 General piping design criteria -------------------------------------------------------- 2
3. RACK ARRANGEMENT
3.1

Items to be considered --------------------------------------------------------------- 3

3.2

Typical Layout ----------------------------------------------------------------------- 3

4. RACK HEIGHT ------------------------------------------------------------------------------- 5


5. PIPING ARRANGEMENT AND DECISION ON THE RACK WIDTH
5.1

Piping Arrangement ------------------------------------------------------------------- 7

5.2

Rack Width -------------------------------------------------------------------------- 15

6. LOADING DATA
6.1

Type of Load ------------------------------------------------------------------------ 16

6.2

Calculation Method ------------------------------------------------------------------ 17

6.3

Layout Aids for Piperack ------------------------------------------------------------ 18

6.4

Weight Table for Thermal Insulation (for reference) --------------------------------- 21

7. EXPANSION LOOPS

------------------------------------------------------------------------ 28

8. RACK STRUCTURE (FOR REFERENCE) ----------------------------------------------------------- 41


9. HISTORY OF THIS MANUAL ------------------------------------------------------------------- 44
Appendix Sample of pipe rack loading data information drawing
Appendix Sample of calculation table for maximum bending stress, anchor force and friction
force

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

OF

44

1. GENERAL
1.1

Purpose
This manual provides Preconditions for standardization of forms, method of expression
and limitations of rack piping drawings which are to be designed/drafted by SECL.

1.2

Application Scope
This manual shall be applied to all jobs executed by SECL unless otherwise specially required
from vendor or licensor.

1.3

Relevant Manuals
(1)
(2)
(3)
(4)

SES-H-101E
SEM-3002
SEM-3101
SEM-3102

"Piping Design"
"Requirements for Drafting Piping Drawing"
"Requirements for Drafting Plot Plan"
"Drafting of Piping Connection Drawing on Battery Limit"

(5) SEM-3104
(6) SEM-3106

"Drafting Key Plan"


"Preparation Piping Note"

(7) SEM-3112
(8) SEM-3113

"Decision Method on Drawing Number"


"Drafting of Plan Drawing"

2. PIPING DESIGN CRITERIA


2.1

Rack piping design criteria


The following piping shall be laid out on the pipe rack with 25% space for future piping.
2.1.1 Process Piping
2.1.2 Blow-down piping (flare piping)
(1) Steam and condensate piping
(2) Boiler feed water piping, potable water, process, water, demineralized water,
cooling water,... etc.
(3) Air (Plant and instrument) piping.
(4) Fuel oil, fuel gas, nitrogen piping
2.1.4 Instrument/electrical duct or cable tray
2.1.5 Catwalk

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

2.2

1998. 9.28

PAGE

OF

44

General Design Criteria

3. RACK ARRANGEMENT
Type
Rack

Within the unit


(1) Process piping
1) Piping to connect equipment located
at 6m distance and over
2) Product piping to carry materials
from tower, heat exchanger, pump,
etc. to the storage area or other
unit and plant.
3) Raw materials or other supply
piping entered into the unit plant.
(2) Blow-down piping (flare piping)
(3) Instrument/electrical duct
(4) Utility piping

O.S.B.L
(1) Process piping
1) Product incoming piping
2) Raw material piping
(2) Utility piping
1) Steam and condensate piping
2) Water piping
(*) Yard piping shall be above-ground
piping as far as space is available.
But rack piping is permissible if yard
piping is not available considering
the walkway and access.

1) Steam and condensate piping


2) Gas, plant air and instrument air
piping
3) Boiler supply water, city water,
process water, demineralized water
piping, and cooling water piping
not buried
4) Fuel oil and gas piping
(5) Catway
Above-

(1) Discharge piping and vibration piping

ground

of reciprocating compressor
(2) Storage and in-out piping with dike
(3) Large size fluid piping

Trench

(1)
(2)
(3)
(4)

Cable duct for electric power


Cooling water piping for pump
Drain recovery piping
Piping extended to the sump tank

Underground

(1) Utility piping


1) Cooling water piping and oily
piping
2) Fire-fighting water piping
3) Water supply piping

(1) In-out piping for raw material and


products

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

OF

44

Rack arrangement is generally subject to the location of process lines such as raw material piping
and products piping and the location of utility lines that enter and leave the unit boundary.
3.1

Items to be considered
(1) Installation and maintenance of equipment and transportation of equipment and materials.
(2) Piping between each unit shall be as short as possible.
(3) Length and number of rack shall be the minimum.

3.2

Typical Layout

(1) Dead end yard lines enter and


leave one end the rack.

(2) Straight through yard, line can


enter and leave both ends of the
rack.

(3) L-shaped yard lines can enter

(4) T-shaped rack piping can enter

and leave north and east of

and leave on three sides of the

the rack.

rack.

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

(5) U-shaped yard lines can enter


and leave all four sides of the
rack.

(7) Complex rack piping arrangement for


a very large chemical plant.

4. RACK HEIGHT

PAGE

OF

(6) Combination of I and T shaped


rack.

44

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

OF

44

(1) The height of top surface of the lowest rack beam shall be subject to the following:

(2) The following shall be considered in deciding the height "H".


1) Observance of minimum height of the following

(Unit : mm)
Classification

H1

Remarks

Maintenance area inside of B.L .

2500

Main road crossing at inside of B.L.

4500

Clearance for big vehicle : 3500

4500

Road traffic act

6000

Road traffic act

6700

Rail road act

Main road crossing at outside of B.L.


(2nd class state road)
Main road crossing at outside of B.L.
(1st class state road)
Incoming railway

2) Decisions shall be made after examining mutual relation between the equipments, and problems
on taking-in, operation and maintenance of equipment.
3) For the minimum height mentioned on above item No.1), consider the highest point of road
paving.
4) According to the road traffic act enforcement ordinance, all facilities such as a bridge,
signs above the road shall have min. 4.5m headroom from lowest point of the road.
5) When the equipment such as exchanger is located under the rack, its highest part shall be
the base of rack height after examining each exchanger as shown on the below.

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

OF

44

For exchanger with hot or cold


insulation, the clearance of
minimum 300mm shall be
provided from the outside of
insulation material.

(3) Double level rack


Difference of height (H) for each level of rack shall be 1000mm, 1500mm, 2000mm as the
standard.

If an angle is necessary, special


caution is required to avoid the
interference with the adjacent pipe.

Type ""
Type ""
Type ""
The figures , and show the elbows connected fitting to fitting and the dimensions of

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

OF

44

the height(h) are shown in the following table.

(Unit : mm)
Nominal Pipe Size

6B

8B

10B

12B

14B

16B

18B

20B

Elbow Dimension

228.6

304.8

381.0

457.2

533.4

609.6

685.8

762.0

Type (90)

458

610

762

916

Type (45)

458

534

610

686

762

Type (30)

337

385

433

479

Nominal Pipe Size

24B

26B

28B

30B

32B

34B

36B

40B

Elbow Dimension

914.4

990.6

1066.8

1143.0

1219.2

1295.4

1371.4

1524.0

Type (90)

Type (45)

915

991

Type (30)

557

625

673

721

762

817

865

961

(Note) :

H 2h
For elbow 90, 45and 30 Consider it as a long radius elbow and
calculate the height.

5. PIPING ARRANGEMENT AND THE RACK WIDTH


5.1

Piping Arrangement
(1) Large size pipes (14" and larger) shall be arranged close to the column in order to
decrease the bending moment of beam.
(2) The utility piping shall be laid on the middle of the rack If the rack has a
single level and these piping shall be laid on the upper level if the rack has two levels.
Piping in the rack shall be arranged according to the "Table of arrangement classification"
on the next page.

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

OF

44

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

OF

Table of arrangement classification

Upper Rack

Lower Rack

Type
Side
Blow-down (Flare) piping

Raw material inlet piping (12B and over)

Raw material inlet piping (10B and under)

P
R
O
C
E
S
S

Product discharge piping

(12B and over)

Product discharge piping

(10B and under)

Overhead piping from tall tower or highly


elevated vessel

Center

Pump discharge piping

Corrosive piping

Piping located between equipments on ground


leved

Vibration piping

Condensate piping

Boiler feed water piping

Hose station piping (water, air, N, etc.)

Plant air piping

Cooling water header piping for pump

DUCT

Center

Piping from tower and vessel to pumps or


exchangers

High and low pressure steam piping

U
T
I
L
I
T
Y

Side

Fuel oil and gas piping

Instrument air piping

Instrument duct

Electric duct

(Note) : Expansion loop may be required.

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

10 OF

44

(3) The end of utility header piping shall be arranged as same as the following figures.

Type

Blind flange

Cap

(*) 300LB and under

8B and under

10B and larger

(*) 600LB and under

6B and under

8B and larger

Class

(Note) : (*) For the class of 900LB and over, the piping similar to the above types shall
be avoided.
(4) Piping with corrosive fluids shall not be installed above the cable duct.
(5) For reciprocating compressor discharge piping, pressure drop valve and drain piping to be
installed on the pipe rack, thorough consideration shall be given to the vibration
protection.
(6) Piping at B.L. connection point shall be arranged through sufficient coordibation with the
client and the relevant contractor, discussing the piping arrangement and the anchor
locations.
(7) Platform or walkway with ladder shall be installed on the rack where frequent operation
and/or maintenance of valves are required.

A ladder hall be installed with a cage .

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

11 OF

44

(8) When necessary to install an expansion loop on the condensate line, do it horizontally to
prevent water hammering.

But, do as follows if horizontal loop is impossible.

(9) Loop of piping shall be grouped considering a fine view.

Make lines into a group and install a large size piping and high temperature piping to
the edge of the rack.

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

12 OF

44

(10) Grounding is necessary on the piping where static electricity is expected to occur.
[Reference]
1) fluid that could be dangerous from static electricity.
1st Petroleum (crude oil, gasoline, solvent, naphtha, tar, light oil, etc.)

Petroleum 2nd Petroleum (kerosene, light oil, diesel oil, xylene, etc.)

3rd Petroleum (heavy oil, lube oil, tars such as creosote oil)

Ether, carbon bisulfide, collodion, acetone, nitric acid ester, formic acid ester,
pyridine, chloro-benzol, animals and plants oils, etc.

2) About the electrification


Safety fluid velocity

1m/sec and under for petroleum in API

Constant fluid velocity

proportional to pipe size

Constant pipe size

proportional to fluid velocity

(*) Pneumatic conveying piping for powders susceptible to the disaster due to static
electricity and non-conductive powders (synthetic resin, wheat powder, etc.).
3) Lug installation criteria
Bonding between pipes
Fabrication and attachment

Lug for bond

of lug by piping contractor

Insulated pipe
L=30+ Insulation thickness

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

13 OF

44

Bonding between valve and pipe

Farication and
Sus Teminal

attachment of lug
by piping contractor

same as bolt hole size


Sus Teminal
* Leave some space
to take out bolts
For piping on the rack, it is recommended to consider the rack column connected
to grounding main line at every 18m as same as the piping.

(11) Harzadous gas piping shall be installed on the upper rack and it shall be away from high
temperature piping.
(12) Install steel shoes on the hot-insulated piping (except for protector) and the coldinsulated piping operating at over 0.
(13) Install support with cradle (rest type or whole circumference type) for cold-insulated
piping operating at 0 and under.

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

14 OF

44

(14) Install support with saddle for thin pipes or large size pipes (D/t > 95) to minimize
local stress.

(But, as above support type is not necessary when the distance of rack

column is short, its application shall be determined after preliminary examination.)

CRADLE

SHOE

SADDLE

(15) Changes in piping direction

Plane bending

3-dimensional bending

(Used in O.S.B.L.)

(Generally used within the unit.)

This type is economical.

This type can be applied to the line


with complicated change of direction.
Care shall be taken for overhang in
the corner area.
(Proper middle beam or dummy supports
may be required.)

(16) Oxygen piping shall not be arranged adjacent to the electrical duct.

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

5.2

1998. 9.28

PAGE

15 OF

44

Rack Width
(1) Piping spacing on the rack shall be decided in accordance with

"Drafting Data C-9

(SEM-3007)".
(Thorough consideration shall be given to the maintenance, hot insulation, cold insulation
and lateral movement by thermal expansion.)
(2) If special valve and instrument are installed on the rack, make decision on the width
considering the space of operation and maintenance.
(3) For the area where there are orifice piping, provide space for installing orifice
considering the orientation of differential pressure taps.
Instrument Hook-Up Drawing

(Note) : * Basically, do not use type "B-2" for superheated steam.


(It is to protect stress corrosion.)
* Type "B-1" and "C-1" shall be generally installed as the following figure.

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

16 OF

(4) Leave 10-15% of space as a rule.


Also provide 20~30% of the space if future extension is expected.
(5) Rack width shall be decided as shown on the below.

B Bo + F
Bo = { (P1 + P2)) + CE } (1 + F)
B

: Rack width

Bo

: Calculated rack width

P1, P2

: Pipe spacing (as per "Drafting Data C-9" in SEM-3007)

CE

: Electric cable duct

: 0.1 ~ 0.15
: For future extension

( included)

6. LOADING DATE
6.1

Type of Load
Type

Description

Direction

Weight of piping, valve and load insulation

Vertical

Sustain
load(Dead

Load by thermal expansion of piping


Thermal load

Reaction force by internal pressure of


expansion bellows.

Horizontal
Horizontal

Load by vibration of piping


Dynamic load
Load by wind and earthquake

Horizontal

Remarks

44

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

Type

Description

Sustained
load
(Live load)

6.2

Direction

Liquid load for hydrostatic pressure test.

Vertical

Snow load (The difference of snowfall


depending on the region shall be considered
in making decision)

Vertical

17 OF

Remarks
Refer to line
schedule.

Calculation Method
(1) Weight calculation criteria of piping, valve and insulation
1) Liquid piping
a) Insulated and subject to hydrostatic pressure test
Load = piping weight + insulation weight + contents weight
b) Un-insulated and subject to hydrostatic pressure test
Load = piping weight + contents weight
c) Insulated and subject to pneumatic pressure test
Load = piping weight + insulation weight + contents weight
d) Un-insulated and subject to pneumatic pressure test
Load = piping weight + contents weight
2) Gas piping
a) Insulated and subject to hydrostatic pressure test
Load = piping weight + insulation weight + water weight
b) Un-insulated and subject to hydrostatic pressure test
Load = piping weight + water weight
c) Insulated and subject to pneumatic pressure test
Load = piping weight + insulation weight
d) Un-insulated and subject to pneumatic pressure test
Load = piping weight
Note : 1) For pipe and insulation weight, refer to weight table of paragraph 6.4.
2) For instrument duct and electric duct, refer to the following table.

44

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

18 OF

44

Instrumentation Design Manual "SEM-5001"


Width (W) Height (H)

Weight (kg/m)

Width (W) Height (H)

Weight (kg/m)

1500 500

515

600 300

150

1400 500

480

500 300

125

1200 400

350

400 200

75

1000 400

290

300 200

60

800 300

190

(*) Allowable span for duct is max. 6000mm.


6.3

Layout aids for piperack


(1)

The stress limit on anchors and guides is 1410 kg/ Max.

(2)

Force limit on anchors and guides is 1000 kg Max. unbalanced force including friction
loads.
Example 1 :

Where Ft = Thermal force


Ft = Friction force
Total unbalanced force = (1600 + 1300) - (1300 + 1000)
= 700 kg
This is within the limiting criteria
Example 2 :

Total unbalanced force = (1900 + 1400) - (700 + 500)


= 2100 kg

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

19 OF

44

This exceeds the limiting criteria of 1000 kg unbalanced force.


Consult lead stress engineer for possible alternatives to comply with the force
limitation.
Notes : 1. For friction loads, we can manually calculate them getting the unit weights from
the table in para.6.4.
2. For thermal loads, we can manually calculate them using the data and nomographs.
But computer program is very well prepared and is it faster, accurate to use
computer for total unbalanced force at the anchor point.
(3)

Expansion loop requirements


a) Generally, if the total expansion in any direction on the piperack is less than
100 mm, the loop could be avoided by locating an anchor in the middle of the run.
b) The total expansion between loop anchors should not exceed 350 mm.
c) The Max. expansion at the change of direction (i.e. points and in the example3)
should not exceed 50 mm, consult the lead stress engineer for any exceptions.

(4)

Location of loops and guides


Example 3 :

Pipe material : ASTM A-53 Gr.B


Design temp.

: 260

Exp. Coefficient : 3.02 mm/m


Commodity

: HC (Vapor)

Insulation

: 50 mm thick calsium silicate


(12.7 kg/m - from weight table)

Friction coefficient = 0.3 ( steel on steel)


a) Total expansion in the East - West direction.
150 3.02 = 453 mm
b) Anchor should be located in such a way that the expansion going into the loop should
not exceed 350 mm and the total unbalanced forces at the anchors should be within

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

20 OF

44

the limiting criteria (para.6.3(2)). Locate anchor at 15 m from point and .


c) Expansion going into the loop
{138 - (215)} 3.02 = 326 mm
d) Expansion loop can be sized manually using data and nomograph.
f) Anchor and guide loads can be calculated manually or by computer. calculating by
computer is more fast and accurate

For W = 1500 mm to 3000 mm, G 60000 mm


For W > 3000 mm, G 12000 mm
Fu = Total unbalanced force.
To locate guides, follow the pipe guide spacing tabulated in
general note 1.6, selection guide of pipe supports (1/8).

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

6.4

1998. 9.28

PAGE

21 OF

44

Weight Table for pipe and Thermal Insulation (for reference)


6.4.1

Nominal
pipe
size
(B)

Calcium silicate hot-insulation ( = 0.22 g/)

Outside
diameter
(mm)

Internal
pipe
water
weight
(kg/m)

Weight of hot-insulation by thickness (THK: mm, WT: kg/m)

25

30

50

65

75

90

115

140

150

175

200

225

250

1/2

21.7

0.8

1.1

2.5

3.9

5.0

6.9

10.9

15.6

17.8

23.8

30.6

38.4

46.9

3/4

27.2

0.9

1.2

2.7

4.1

5.3

7.3

11.3

16.2

18.4

24.5

31.4

39.2

47.9

34.0

0.6

1.0

1.3

2.9

4.4

5.7

7.7

11.8

16.8

19.1

25.3

32.3

40.3

49.1

48.6

1.4

1.3

1.6

3.4

5.1

6.4

8.6

13.0

18.3

20.6

27.0

34.4

42.5

51.6

60.5

2.2

1.5

1.9

3.8

5.6

7.0

9.4

13.9

19.4

21.8

28.5

36.0

44.4

53.7

76.3

3.6

1.8

2.2

4.4

6.3

7.8

10.3

15.2

20.9

23.5

30.4

38.2

46.9

56.4

89.1

5.1

2.0

2.5

4.8

6.9

8.5

11.1

16.2

22.2

24.8

31.9

40.0

48.8

58.6

114.3

8.7

2.4

3.0

5.7

8.1

9.8

12.7

18.2

24.6

27.4

35.0

43.4

52.8

62.9

165.2

18.9

3.3

4.0

7.4

10.3

12.5

15.9

22.3

29.5

32.7

41.1

50.5

60.7

71.7

216.2

32.9

4.3

5.1

9.2

12.6

15.1

19.1

26.3

34.5

38.0

47.3

57.5

68.6

80.6

10

267.4

50.7

5.1

6.2

11.0

14.3

17.7

22.2

30.4

39.4

43.3

53.5

64.6

76.6

89.4

12

318.5

72.9

5.9

7.2

12.7

17.2

20.4

25.4

34.5

44.4

48.6

59.7

71.7

84.5

98.2

14

355.6

92.7

6.6

8.0

14.0

18.9

22.3

27.7

37.4

50.2

52.4

64.2

76.8

90.3

104.6

16

406.4

122.1

7.5

9.0

15.8

21.2

25.0

30.9

41.4

52.9

57.7

70.3

83.8

98.2

113.4

18

457.2

155.6

8.3

10.1

17.5

23.5

27.6

34.0

45.5

57.8

62.9

76.5

90.8

106.1

122.2

20

508.0

193.1

9.2

11.2

19.3

25.7

30.2

37.2

49.5

62.7

68.2

82.6

97.9

114.0

131.0

22

558.8

234.7

10.1

12.2

21.0

28.0

32.9

40.4

53.6

67.6

73.5

88.8

104.9

121.9

139.8

24

609.6

279.6

11.0

13.3

22.8

30.3

35.5

43.5

57.6

72.5

78.7

94.9

111.9

129.8

148.5

26

660.4

330.0

11.8

14.3

24.5

32.6

38.1

46.7

61.6

77.4

84.0

101.0

118.9

137.7

157.3

28

711.2

383.8

12.7

15.4

26.3

34.9

40.8

52.9

65.7

82.4

89.3

107.2

126.0

145.6

166.1

30

762.0

440.6

13.6

16.4

28.1

37.2

43.4

53.0

69.7

87.3

94.5

113.3

133.0

153.5

174.9

32

812.8

502.4

14.5

17.5

29.9

39.4

46.0

56.2

73.7

92.2

99.8

119.5

140.0

161.4

183.6

34

863.6

568.2

15.4

18.5

31.6

41.8

48.7

59.3

77.8

97.1

105.1

125.6

147.0

169.3

192.4

36

914.4

638.1

16.2

19.6

33.3

44.0

51.3

62.2

81.8

102.0

110.3

131.8

154.0

177.2

201.2

40

1016.0

782.8

18.0

21.7

36.8

48.6

56.6

68.8

89.9

111.9

120.9

144.1

168.1

193.0

218.7

42

1066.8

840.0

18.9

22.7

38.6

50.8

59.2

72.0

93.9

116.8

126.1

150.2

175.1

200.9

227.5

44

1117.6

944.7

19.7

23.8

40.3

53.1

61.8

75.1

98.0

121.7

131.4

156.3

182.1

208.8

236.3

48

1219.2

1125.0

21.5

25.9

43.9

57.7

67.1

81.4

106.0

131.5

141.9

168.6

196.2

224.6

253.9

54

1371.6

1426.0

24.1

29.1

49.1

64.5

75.0

90.9

118.2

146.3

157.7

187.1

217.2

248.3

280.2

60

1524.0

1763.0

26.8

32.2

54.4

71.4

82.9

100.4

130.3

161.0

173.5

205.5

238.3

272.0

306.5

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

6.4.2
Nomina
l
pipe
size
(B)

PAGE

22 OF

44

Perlite hot-insulation ( = 0.20 g/)

Outsid
e
diamet
er
(mm)

Interna
l
pipe
water
weight
(kg/m)

Weight of hot-insulation by thickness (THK: mm, WT: kg/m)


25

30

50

65

75

90

115

140

150

175

200

225

250

1/2

21.7

0.7

1.0

2.3

3.5

4.6

6.3

9.9

14.2

16.2

21.6

27.9

34.9

42.7

3/4

27.2

0.8

1.1

2.4

3.8

4.8

6.6

10.3

14.7

16.7

22.2

28.6

35.7

43.5

34.0

0.6

0.9

1.2

2.6

4.0

5.1

7.0

10.8

15.3

17.3

23.0

29.4

36.6

44.6

48.6

1.4

1.2

1.5

3.1

4.6

5.8

7.8

11.8

16.6

18.7

24.6

31.2

38.7

46.9

60.5

2.2

1.3

1.7

3.5

5.1

6.4

8.5

12.7

17.6

19.8

25.9

32.7

40.4

48.8

76.3

3.6

1.6

2.0

4.0

5.8

7.1

9.4

13.8

19.0

21.3

27.6

34.7

42.6

51.3

89.1

5.1

1.8

2.3

4.4

6.3

7.7

10.2

14.7

20.2

22.6

29.0

36.5

44.4

53.4

114.3

8.7

2.2

2.7

5.2

7.3

8.9

11.6

16.6

22.4

24.9

31.8

39.5

48.0

57.2

165.2

18.9

3.0

3.7

6.8

9.4

11.3

14.4

20.2

26.8

29.7

37.4

45.9

55.2

65.2

216.2

32.9

3.8

4.6

8.4

11.5

13.7

17.3

23.9

31.3

34.5

43.0

52.3

62.4

73.2

10

267.4

50.7

4.6

5.6

10.0

13.6

16.1

20.2

27.6

35.8

39.3

48.6

58.7

69.6

81.3

12

318.5

72.9

5.4

6.6

11.6

15.7

18.5

23.1

31.3

40.3

44.2

54.3

65.2

76.8

89.3

14

355.6

92.7

6.0

7.3

12.7

17.2

20.3

25.2

34.0

43.6

47.7

58.3

69.8

82.1

95.1

16

406.4

122.1

6.8

8.2

14.3

19.3

22.7

28.1

37.7

48.1

52.4

63.9

76.2

89.3

103.1

18

457.2

155.6

7.6

9.2

15.9

21.3

25.1

30.9

41.3

52.5

57.2

69.5

82.6

96.4

111.1

20

508.0

193.1

8.4

10.1

17.5

23.4

27.5

33.8

45.0

57.0

62.0

75.1

89.0

103.6

119.1

22

558.8

234.7

9.2

11.1

19.1

25.5

30.0

36.7

48.7

61.5

66.8

80.7

95.4

110.8

127.0

24

609.6

279.6

10.0

12.1

20.7

27.6

32.3

39.6

52.4

65.9

71.6

86.3

101.7

118.0

136.6

26

660.4

330.0

10.8

13.0

22.3

29.6

34.7

42.4

56.0

70.4

76.4

91.9

108.1

125.2

143.0

28

711.2

383.8

11.6

14.0

23.9

31.7

37.0

45.3

59.7

74.9

81.2

97.4

118.3

132.4

151.0

30

762.0

440.6

12.4

14.9

25.5

33.8

39.4

48.2

63.4

79.3

86.0

103.0

120.9

139.5

159.0

32

812.8

502.4

13.2

15.9

27.1

35.8

41.8

51.1

67.0

83.8

90.7

108.6

127.3

146.7

166.9

34

863.6

568.2

14.0

16.8

28.7

37.9

44.2

53.9

70.7

88.3

95.5

114.2

133.7

153.9

174.9

36

914.4

638.1

14.8

17.8

30.3

40.0

46.6

56.8

74.4

92.7

100.3

119.8

140.0

161.1

182.9

40

1016.0

782.8

16.4

19.7

33.5

44.1

51.4

62.5

81.7

101.7

109.9

131.0

152.8

175.4

198.9

42

1066.8

840.0

17.1

20.7

35.1

46.2

53.8

65.4

85.4

106.2

114.7

136.5

159.2

182.6

206.8

44

1117.6

944.7

17.9

21.6

36.7

47.9

56.2

68.3

88.3

110.6

119.5

142.1

165.6

189.8

214.8

48

1219.2

1125.0

19.5

23.5

39.9

52.4

61.0

74.0

96.4

119.6

129.0

153.3

178.3

204.2

230.8

54

1371.6

1426.0

21.9

26.4

44.7

58.7

68.2

82.7

107.6

133.0

143.4

170.1

197.5

225.7

254.7

60

1524.0

1763.0

24.3

29.3

49.4

64.9

75.4

91.3

118.4

146.4

157.8

186.8

216.6

247.3

278.7

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

6.4.3
Nomina
l
pipe
size
(B)

Outside
diamete
r
(mm)

PAGE

23 OF

44

Urethane foam cold-insulation ( = 0.035 g/)


Interna
l
pipe
water
weight
(kg/m)

Weight of cold-insulation by thickness (THK: mm, WT: kg/m)


25

30

40

50

65

75

90

115

140

150

175

200

225

250

1/2

21.7

0.1

0.2

0.3

0.4

0.6

0.8

1.1

1.7

2.5

2.8

3.8

4.9

6.1

7.5

3/4

27.2

0.1

0.2

0.3

0.4

0.7

0.8

1.2

1.8

2.6

2.9

3.9

5.0

6.2

7.6

34.0

0.6

0.2

0.2

0.3

0.5

0.7

0.9

1.2

1.9

2.7

3.0

4.0

5.1

6.4

7.8

48.6

1.4

0.2

0.3

0.4

0.5

0.8

1.0

1.4

2.1

2.9

3.3

4.3

5.5

6.8

8.2

60.5

2.2

0.2

0.3

0.4

0.6

0.9

1.1

1.5

2.2

3.1

3.5

4.5

5.7

7.1

8.5

76.3

3.6

0.3

0.4

0.5

0.7

1.0

1.2

1.6

2.4

3.3

3.7

4.8

6.1

7.5

9.0

89.1

5.1

0.3

0.4

0.6

0.8

1.1

1.4

1.8

2.6

3.5

3.9

5.1

6.4

7.8

9.3

114.3

8.7

0.4

0.5

0.7

0.9

1.3

1.6

2.0

2.9

3.9

4.4

5.6

6.9

8.4

10.0

165.2

18.9

0.5

0.6

0.9

1.2

1.6

2.0

2.5

3.5

4.7

5.2

6.5

8.0

9.7

11.4

216.2

32.9

0.7

0.8

1.1

1.5

2.0

2.4

3.0

4.2

5.5

6.0

7.5

9.1

10.9

12.8

10

267.4

50.7

0.8

1.0

1.4

1.8

2.3

2.8

3.5

4.8

6.3

6.9

8.5

10.3

12.2

14.2

12

318.5

72.9

0.9

1.1

1.6

2.0

2.7

3.2

4.0

5.5

7.1

7.7

9.5

11.4

13.4

15.6

14

355.6

92.7

1.0

1.3

1.7

2.2

3.0

3.5

4.4

6.0

8.0

8.3

10.2

12.2

14.4

16.6

16

406.4

122.1

1.2

1.4

2.0

2.5

3.4

4.0

4.9

6.6

8.4

9.2

11.2

13.3

15.6

18.0

18

457.2

155.6

1.3

1.6

2.2

2.8

3.7

4.4

5.4

7.2

9.2

10.0

12.1

14.4

16.9

19.4

20

508.0

193.1

1.5

1.8

2.4

3.1

4.1

4.8

5.9

7.9

10.0

10.9

13.1

15.6

18.1

20.8

22

558.8

234.7

1.6

1.9

2.6

3.3

4.5

5.2

6.4

8.5

10.8

11.7

14.1

16.7

19.4

22.2

24

609.6

279.6

1.8

2.1

2.9

3.6

4.8

5.6

6.9

9.2

11.5

12.5

15.1

17.8

20.7

23.6

26

660.4

330.0

1.9

2.3

3.1

3.9

5.2

6.1

7.4

9.8

12.3

13.4

16.1

18.9

21.9

25.0

28

711.2

383.8

2.0

2.5

3.3

4.2

5.6

6.5

8.4

10.5

13.1

14.2

17.1

20.0

23.2

26.4

30

762.0

440.6

2.2

2.6

3.5

4.5

5.9

6.9

8.4

11.1

13.9

15.0

18.0

21.2

24.4

27.8

32

812.8

502.4

2.3

2.8

3.8

4.8

6.3

7.3

8.9

11.7

14.7

15.9

19.0

22.3

25.7

29.2

34

863.6

568.2

2.5

2.9

4.2

5.0

6.7

7.7

9.4

12.4

15.4

16.7

20.0

23.4

26.9

30.6

36

914.4

638.1

2.6

3.1

4.2

5.3

7.0

8.2

9.9

13.0

16.2

17.5

20.1

24.5

28.2

32.0

40

1016.0

782.8

2.9

3.5

4.6

5.9

7.7

9.0

10.9

14.3

17.8

19.2

22.9

26.7

30.7

34.8

42

1066.8

840.0

3.0

3.6

4.9

6.1

8.1

9.4

11.5

14.9

18.6

20.1

23.9

27.9

32.0

36.2

44

1117.6

944.7

3.1

3.8

5.1

6.4

8.4

9.8

11.9

15.6

19.4

20.9

24.9

29.0

33.2

37.6

48

1219.2

1125.0

3.4

4.1

5.5

7.0

9.2

10.7

13.0

16.8

20.9

22.6

26.8

31.2

35.7

40.4

54

1371.6

1426.0

3.8

4.6

6.2

7.8

10.3

11.9

14.5

18.8

23.3

25.1

29.8

34.6

39.5

44.6

60

1524.0

1763.0

4.3

5.1

6.9

8.7

11.4

13.2

16.0

20.7

25.6

27.6

32.7

37.9

43.3

47.8

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

6.4.4

Nominal
pipe
size
(B)

PAGE

24 OF

44

Cellular glass cold-insulation ( = 0.16 g/)

Outside
diamete
r
(mm)

Interna
l
pipe
water
weight
(kg/m)

Weight of cold-insulation by thickness (THK: mm, WT: kg/m)


25

30

40

50

65

75

90

115

140

150

175

200

225

1/2

21.7

0.6

0.8

1.2

1.8

2.8

3.6

5.1

7.9

8.2

8.9

12.6

12.2

16.7

3/4

27.2

0.7

0.9

1.4

1.9

3.0

3.9

5.3

8.2

8.8

9.5

13.0

13.2

17.3

34.0

0.6

0.7

1.0

1.5

2.1

3.2

4.1

5.6

8.6

9.1

9.8

13.6

13.6

18.1

48.6

1.4

0.9

1.2

1.8

2.5

3.7

4.7

6.3

9.5

10.1

10.9

14.9

15.0

19.7

60.5

2.2

1.1

1.7

2.0

2.8

4.1

5.1

6.8

10.1

10.9

11.8

14.2

16.2

18.8

76.3

3.6

1.3

1.6

2.3

3.2

4.6

5.7

7.5

11.1

12.1

13.0

17.4

17.8

22.9

89.1

5.1

1.4

1.8

2.6

3.5

5.0

6.2

8.1

12.1

13.0

14.0

18.8

19.1

24.8

114.3

8.7

1.8

2.2

3.1

4.1

5.9

7.1

9.2

13.3

14.7

15.9

20.7

21.6

27.2

165.2

18.9

2.4

2.9

4.1

5.4

7.5

9.1

11.5

16.2

18.3

19.7

25.2

26.8

32.9

216.2

32.9

3.0

3.7

5.2

6.7

9.2

11.0

13.9

19.2

21.9

23.5

29.7

31.9

38.7

10

267.4

50.7

3.7

4.5

6.2

8.0

10.9

12.9

16.2

22.1

25.5

27.4

34.2

37.0

44.5

12

318.5

72.9

4.3

5.3

7.2

9.3

12.5

14.8

18.5

25.1

29.1

31.3

38.7

42.2

50.3

14

355.6

92.7

4.8

5.8

8.0

10.2

13.7

15.9

20.2

27.2

31.7

34.0

41.9

45.9

54.5

16

406.4

122.1

5.4

6.6

9.0

11.5

15.4

18.1

22.5

30.1

35.3

37.9

46.4

51.0

60.2

18

457.2

155.6

6.1

7.3

10.0

12.7

17.1

20.1

24.8

33.1

38.9

41.7

50.9

56.1

66.0

20

508.0

193.1

6.7

8.1

11.0

14.0

18.7

22.0

27.1

36.0

42.4

45.5

55.3

61.2

71.7

22

558.8

234.7

7.3

8.9

12.0

15.3

20.4

23.9

29.4

38.9

46.0

49.4

59.8

66.3

77.4

24

609.6

279.6

8.0

9.6

13.0

16.6

22.0

25.8

31.6

41.9

49.6

53.2

64.2

74.2

83.2

26

660.4

330.0

8.6

10.4

14.9

17.9

23.4

27.7

33.9

44.8

53.2

57.0

68.7

76.5

88.9

28

711.2

383.8

9.3

11.2

15.1

19.1

25.4

29.6

36.2

47.8

56.7

60.9

73.2

81.7

94.7

30

762.0

440.6

9.9

11.9

16.1

20.4

27.0

31.6

38.5

50.7

60.3

64.7

77.7

86.8

100.4

32

812.8

502.4

10.5

12.7

17.1

21.7

28.7

33.5

40.8

53.6

63.9

68.5

82.1

91.9

106.2

34

863.6

568.2

11.2

13.5

18.2

23.1

30.3

35.4

43.1

56.6

67.5

72.4

86.6

97.0

111.9

36

914.4

638.1

11.8

14.2

19.2

24.2

32.0

37.3

45.4

59.5

74.2

80.3

95.8

112.0

128.9

40

1016.0

782.8

13.1

15.8

21.2

26.8

35.3

41.1

50.0

65.4

81.3

87.9

104.8

122.2

140.4

42

1066.8

840.0

13.7

16.5

22.3

28.1

37.0

43.0

52.4

68.3

84.9

91.7

109.2

127.4

146.1

44

1117.6

944.7

14.4

17.3

23.3

29.3

38.6

45.0

54.6

71.3

88.5

95.6

113.7

132.5

151.8

48

1219.2

1125.0

15.6

18.8

25.3

31.9

42.0

48.8

59.2

77.1

95.6

103.2

122.6

142.7

164.3

54

1371.6

1426.0

17.6

21.1

28.4

35.7

46.9

54.5

66.1

85.9

106.4

114.7

136.0

158.0

180.6

60

1524.0

1763.0

19.5

23.4

31.4

39.6

51.9

60.3

73.0

94.7

117.8

127.0

149.5

174.3

197.8

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

6.4.5

PAGE

25 OF

44

Pipe weight
a: ANSI B36.10 steel pipe schedule numbers
b: ANSI B36.10 steel pipe nominal wall thicknes designation
c: ANSI B36.10 stainless steel pipe schedule numbers.

Normal
pipe
size

schedule
a

wall
thick.
(mm)

40
80
160
-

Std
Xs
XXS

5S
10S
40S
80S
-

1.65
2.11
2.77
3.73
4.75
7.47

0.801
1.000
1.266
1.619
1.941
2.551

0.254
0.230
0.196
0.151
0.110
0.032

40
80
160
-

Std
XS
XXS

5S
10S
40S
80S
-

1.65
2.11
2.77
3.73
4.75
7.47

0.801
1.000
1.266
1.619
1.941
2.551

0.254
0.230
0.196
0.151
0.110
0.032

40
80
160
-

Std
Xs
XXS

5S
10S
40S
80S
-

1.65
2.11
2.87
3.91
5.54
7.82

1.018
1.275
1.683
2.194
2.883
3.633

0.429
0.396
0.342
0.279
0.191
0.095

40
80
160
-

Std
XS
XXS

5S
10S
40S
80S
-

1.65
2.77
3.38
4.55
6.35
9.09

1.292
2.089
2.499
3.232
4.232
5.445

0.711
0.609
0.557
0.463
0.336
0.182

40
80
160
-

Std
XS
XXS
-

5S
10S
40S
80S
-

1.65
2.77
3.68
5.08
7.14
10.16
13.34
16.51

0.740
0.740
4.045
5.404
7.231
9.536
11.474
12.915

0.689
0.655
1.313
1.139
0.905
0.613
0.366
0.183

2"

40
80
160
-

Std
XS
XXS
-

5S
10S
40S
80S
-

1.65
2.77
3.91
5.54
8.71
11.07
14.27
17.45

2.387
3.926
5.436
7.474
11.078
13.437
16.194
18.431

2.554
2.354
2.165
1.905
1.445
1.144
0.793
0.507

2"

40
80
160
-

Std
XS
XXS
-

5S
10S
40S
80S
-

2.11
3.05
5.16
7.01
9.53
14.02
17.15
20.32

3.683
5.255
8.621
11.401
14897
20.388
23.607
26.384

3.719
3.514
30.89
2.734
2.284
1.588
1.179
0.825

1/2"

3/4"

1"

weight
(kg/m)

weight
of water
(kg/m)

Normal
pipe
size

schedule
a

wall
thick.
(mm)

weight
(kg/m)

weight
of water
(kg/m)

2"

40
80
160
-

Std
XS
XXS
-

5S
10S
40S
80S
-

2.11
3.05
5.16
7.01
9.53
14.02
17.15
20.32

3.683
5.255
8.621
11.401
14897
20.388
23.607
26.384

3.719
3.514
30.89
2.734
2.284
1.588
1.179
0.825

3"

40
80
160
-

std
XS
XXS
-

5S
10S
40S
80S
-

2.11
3.05
5.49
7.62
11.10
15.24
18.42
21.59

4.509
6.444
11.280
15.254
21.311
27.651
31.977
35.801

5.625
5.372
4.762
4.262
3.494
2.680
2.130
1.641

4"

40
80
120
160
-

Std
XS
XXS
-

5S
10S
40S
80S
-

2.11
3.05
4.78
6.02
8.56
11.10
12.70
13.49
17.12
20.32
23.50

5.834
8.349
12.739
16.058
22.293
28.216
31.788
33.499
40.985
47.046
52.560

9.524
9.182
8.631
8.200
7.411
6.667
6.191
5.983
5.030
4.262
3.558

6"

40
80
120
160
-

Std
XS
XXS
-

5S
10S
40S
80S
-

2.77
3.40
5.56
7.11
10.97
14.27
18.24
21.95
25.40
28.58

7.992
13.825
22.353
28.231
42.518
54.155
67.415
79.112
89.404
98.345

20.805
20.448
19.495
18.617
16.802
15.328
13.632
12.159
10.840
9.699

8"

20
30
40
60
80
100
120
140
160
-

Std
XS
-

5S
10S
40S
80S
-

2.77
3.76
5.56
6.35
7.04
8.18
10.31
12.70
15.06
18.24
20.62
23.01
25.40
28.58

14.748
19.942
29.228
33.276
36.758
42.488
53.039
64.573
75.704
90.229
100.840
111.153
121.194
134.107

35.821
35.106
34.080
33.454
33.008
32.279
30.939
29.466
28.037
26.192
24.838
23.513
22.241
20.594

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

6.4.5

ormal
pipe
size

10"

12"

14"

PAGE

26 OF

44

weight
(kg/m)

weight
of water
(kg/m)

Pipe weight (cont'd)

schedule
a

wall
thick.
(mm)

20
30
40
60
80
100
120
140
160
-

Std
XS
-

5S
10S
40S
80S
-

3.40
4.19
5.56
6.35
7.80
9.27
12.70
15.06
18.24
21.41
22.23
25.40
28.58
31.75
38.10

22.546
27.829
36.654
41.729
50.956
60.242
81.463
95.735
114.486
132.746
137.330
154.965
172.109
188.732
220.535

55.658
54.914
53.872
53.277
52.087
50.747
48.069
46.283
43.902
41.669
41.074
38.842
36.609
34.526
30.508

20
30
40
60
80
100
120
140
160

Std
XS
-

5S
10S
40S
80S
-

3.96
4.57
6.35
8.38
9.53
10.31
12.70
14.27
17.45
19.05
21.41
22.23
25.40
28.58
31.75
-

31.237
36.014
49.676
65.138
73.755
79.663
97.357
108.876
131.720
143.164
159.534
165.040
186.753
207.870
228.586
-

78.428
77.683
76.046
73.963
72.921
72.177
69.945
68.457
65.480
640141
61.909
61.165
58.486
55.807
53.277
51.938

10
20
30
40
60
80
100
120
140
160

Std
XS
-

5S
10S
-

3.96
4.78
5.33
5.56
6.35
7.14
7.92
8.74
9.53
11.10
11.91
12.70
15.06
15.88
19.05
23.80
27.76
31.75
35.71

34.228
41.223
45.985
47.920
54.631
61.313
67.980
74.707
81.210
94.307
100.899
107.284
126.362
132.866
157.941
194.551
224.225
253.320
281.446

94.798
93.905
93.458
93.161
92.417
91.524
90.631
89.738
88.845
87.357
86.315
85.571
83.190
82.297
79.172
74.409
70.689
66.969
63.397

weight
(kg/m)

weight
of water
(kg/m)

Normal
pipe
size

schedule
a

wall
thick.
(mm)

16"

10
20
30
40
60
80
100
120
140
160

Std
XS
-

5S
10S
-

4.19
4.78
6.35
7.92
9.53
12.70
16.66
21.41
26.19
30.94
36.50
40.46

41.669
47.622
62.578
77.922
93.131
123.177
159.980
203.078
245.298
286.164
332.819
364.770

124.264
123.520
121.734
119.799
117.716
113.846
109.233
103.727
98.369
93.161
87.208
83.190

18"

10
20
30
40
60
80
100
120
140
160

Std
XS
-

5S
10S
-

4.19
4.78
6.35
7.92
9.53
11.10
12.70
14.27
19.05
23.80
29.36
34.93
39.67
45.24

46.134
53.575
70.525
87.848
105.051
122.121
139.071
155.888
205.623
254.108
309.484
363.326
408.106
459.121

158.046
157.302
155.218
152.986
150.605
148.670
146.438
144.354
137.955
131.705
124.561
117.865
112.060
105.661

20"

10
20
30
40
60
80
100
120
140
160

Std
XS
-

5S
10S
-

4.78
5.54
6.35
9.53
12.70
15.06
20.62
22.23
26.19
32.54
38.10
44.45
49.99

59.528
68.457
78.472
116.972
154.965
182.9132
47.635
265.984
310.838
381.125
441.055
507.621
564.039

194.953
193.762
192.720
187.512
182.750
179.178
171.142
168.761
162.808
153.789
146.289
137.806
130.812

22"

10
20
30
30
80
100
120
140
160

Std
XS
-

5S
10S
-

4.78
5.54
6.35
9.53
12.70
15.88
19.05
22.23
28.58
34.93
41.28
47.63
53.98

65.480
75.898
86.315
129.472
171.142
212.811
252.992
293.173
373.535
450.921
526.819
599.740
671.173

236.771
235.431
234.241
228.735
223.526
218.169
212.960
207.751
197.631
187.809
177.987
168.612
159.534

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

6.4.5

Normal
pipe
size

PAGE

44

weight
(kg/m)

weight
of water
(kg/m)

Pipe weight (cont'd)

schedule
a

wall
thick.
(mm)

10
20
30
40
60
80
100
120
140
160
10
20
-

Std
XS
Std
XS
-

5S
-

6.35
9.53
12.70
17.27
15.88
17.45
19.05
5.54
22.23
24.59
30.94
38.89
46.02
52.37
59.51
6.35
7.92
9.53
12.70
15.88
19.05
22.23
25.40
28.58

94.366
140.812
186.753
209.537
232.202
254.733
277.160
81.850
321.449
354.353
441.040
546.761
639.013
718.990
806.509
99.709
127.984
153.283
202.394
251.504
300.614
349.724
397.346
444.969

279.780
273.529
268.023
265.046
262.219
259.391
256.564
281.119
250.909
246.742
235.580
222.187
210.430
200.161
189.000
329.485
326.211
323.086
316.687
310.436
304.186
297.935
291.834
285.881

28"

10
20
30
-

Std
XS
-

6.35
7.92
9.53
12.70
15.88
19.05
22.23
25.40
28.58

110.126
136.913
165.189
218.764
272.339
324.425
376.512
428.598
480.685

382.911
379.488
375.917
369.071
362.225
355.528
348.831
342.283
335.735

30"

10
20
30
40
-

Std
XS
-

5S
10S
-

6.35
7.92
9.53
12.70
15.88
19.05
22.23
25.40
28.58

117.567
147.331
177.094
235.134
291.685
348.236
404.787
461.339
516.402

440.950
437.081
433.361
425.920
418.628
411.633
404.490
397.346
390.203

24"

27 OF

weight
(kg/m)

weight
of water
(kg/m)

Normal
pipe
size

schedule
a

wall
thick.
(mm)

32"

10
20
30
40
-

Std
XS
-

6.35
7.92
9.53
12.70
15.88
17.48
19.05
22.23
25.40
28.58

126.496
157.748
189.000
250.016
311.031
342.283
372.047
433.063
492.591
552.118

502.710
498.841
494.823
486.935
479.048
474.732
471.309
463.720
455.981
448.391

34"

10
20
30
40
-

Std
XS
-

6.35
7.92
9.53
12.70
15.88
17.48
19.05
22.23
25.40
28.58

133.937
166.677
200.906
266.386
331.866
364.606
395.585
461.339
525.331
587.835

568.488
564.470
559.857
551.820
543.189
538.873
535.004
526.968
518.783
510.746

36"

10
20
30
40
-

Std
XS
-

6.35
7.92
9.53
12.70
15.88
19.05
22.23
25.40
28.58

142.866
177.094
212.811
282.756
351.213
419.669
488.126
556.583
623.551

638.582
634.117
629.653
620.724
611.794
603.163
594.383
585.751
577.269

42"

20
30
40
-

Std
XS
-

6.35
9.53
12.70
15.88
19.05
25.40
31.75
38.10

166.677
248.528
330.3784
10.740
491.102
651.827
809.575
965.835

572.674
862.108
851.691
841.422
831.005
810.765
790.526
770.733

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

7.

1998. 9.28

PAGE

28 OF

44

Expansion Loops
Loops designed according to these charts will be stressed to the allowable limit for A-53 Gr.B
seamless Pipe.

or equal, with LR elbows of the same thicikness as straight pipe.

Do not use for weaker material, or extraploate beyond the range of the charts.
With long expansion lenghts and nested loops, investigate pipe movements.
If thrusts are critical, consult stress section.
The distance between the guides. "G" is a minimum.
If there is not sufficient room to accommodate the depth of loop shown on the chart, then some
relief can be found by widening the loop.

This effect is small, and can only be counted on within

the following limits:

To reduce H by 0.3m, increase W by 3.6m


To reduce H by 0.6m, increase W by 7.2m
If W > 6m then G 2W
H always 1.5m, even after reduction.
No. reduction of H greatr than 0.6m is permitted.
i.e., No increase of W greater than 7.2m permitted.
If it is desirable from a layout point of view, W may always be safely increased without any
decrease on H, providing that:
W anchor distance
G 2W
For loops in which there is a vertical offset:

No credit may be taken if the dimensiion V is a minimum-i.e. fitting to fitting.


If V consists partly of straight pipe, the flexibility of the loop will be increased, and the
amount of this increase shall be checked by stress engineer.

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

7.1 For 3" std wt to xxs inclusive

PAGE

29 OF

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

7.2 For 4" std wt to xxs inclusive

PAGE

30 OF

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

7.3 For 6" std wt to xxs inclusive

PAGE

31 OF

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

7.4 For 8" std wt to xxs inclusive

PAGE

32 OF

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

7.5 For 10" std wt to xxs inclusive

PAGE

33 OF

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

7.6 For 12" std wt to xxs inclusive

PAGE

34 OF

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

7.7 For 14" std wt to xxs inclusive

PAGE

35 OF

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

7.8 For 16" std wt to xxs inclusive

PAGE

36 OF

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

7.9 For 18" std wt to xxs inclusive

PAGE

37 OF

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

7.10 For 20" std wt to xxs inclusive

PAGE

38 OF

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

7.11 For 24" std wt to xxs inclusive

PAGE

39 OF

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

7.12 For 30" std wt to xxs inclusive

PAGE

40 OF

44

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

41 OF

44

8. RACK STRUCTURE (for reference)


(1) Allow sufficient rack width between columns. (Refer para.5)
(Reference example) Rack span by plant
(Unit : mm)
Type of plant

Rack span

Urea plant (6002,000 T/Y)

6000

Pitch Coke Plant

6000

Ethylene plant (200,000300,000 T/Y)

10000

Methanol, Polybuthyl, Refinery

6000 8000

(2) For conditions of rack span, decision shall be made considering the following:
1) Mutual relation with plot of each machinery
2) Relation with pipe diameter
Decision on what the minimum pipe diameter of rack piping shall be and what the allowable
bending of the minimum pipe diameter shall be.
3) Relation with pipe weight
Fluid weight of pipe, pipe weight, valve weight and insulation weight.
4) Support for special piping
Relation with piping whose support span is short, such as copper, many kinds of plastic and
glass lining pipes.
5) Relation with deflection
If deflection of pipe is too great, drainage is not good, fluid which is in the slurry state
of high boiling point produces crystals and condensible vapor such as steam and dowtherm
vapor causes water hammering.

SEM - 3036E

DESIGN MANUAL

REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

42 OF

44

(3) Basically, do not use assembled column for rack column.


(4) For rack column around structure or building, use columns of structure or building column
together if possible, and allow easy access from the ground.
(5) If necessary, rack shall be grounded.
(6) Rack column shall be fire proofed where necessary.
Construction method and range of fire proof shall be in accordance with the job specific
requirements.
(7) If rack is long (specially for O.S.B.L), provide one

joint

bolt slot at the beam connection at every 5060m to absorb the thermal expansion
from temperature changes.

And, do not joint the crossing rack each other.

(8) If there is expansion loop, or a lot of branch piping is expected to the unit on the rack,
indicate it on the structure planning drawing of the below form.

(9) Basically, ladders shall be installed at every 4060m of the rack considering the relation of
each area and cat way.
(10) Install bracing on the rack within the range that it does not interfere with pipe run,
operation and maintenance.

(One bracing shall be installed at least every six span of racks.)

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

1998. 9.28

PAGE

43 OF

44

(11) Examples of rack structure


1) 1 level rack (there is also reinforced concrete.) : L = 6 m

2) 2 level
Normal structure (number of beam is 2 : one on the upper and the other on the lower) :
L = 6 m

When beam is one : L = 6 m

When beam is structured with truss :

L = 1015m

(12) The maximum deflection of rack beam shall be generally 1/300 against 2 span.

DESIGN MANUAL

SEM - 3036E
REV. : 5

RACK PIPING
DATE :

9.

1998. 9.28

PAGE

44 OF

History of This Manual


Rev.

Date

1996. 11. 15

Description
(1) Progress of Enactment
This manual is enacted in accordance with Engineering Division
Strategic Plan, regarding the work of the rack piping.
(2) Written by :

(Piping Engineering Team)


Koh Bong Hwan, Lee Joo Sang

Editorial Supervisor : Jeong Kyung Hwa


5

1998. 9. 28

(1) This manual is revised in accordance with piping design team


Strategic Plan of 1998, regarding the work of the rack piping.
(2) Piping engineerirng team
Written by

: Mr. H.C. Chang, Lee joo sang

Reviewed by

: Jeong kyung hwa

editorial Supervisor : Lee myung hak

44

Appendix : Sample of pipe rack loading data information drawing

Appendix :

Sample of calculation table for maximum bending stress, anchor force and friction force