Professional Documents
Culture Documents
Slab Design SEFI
Slab Design SEFI
Here the aspect ratio Ly/Lx is greater than 2 hence the slab is designed as a one way slab.
OneShortEdgeDisContinuous:
Basic dimensions of slab
Lx
Ly
3
6.5
2.167 >2
Hence designed as an one way slab
25 mm
150.00 mm
120.00 mm
10 mm
20 N/mm
415 N/mm
d'
D
d
fck
fy
=
=
=
=
=
=
DL
FF
LL
=
=
=
3.750 kN/m
1.9 kN/m
1.5 kN/m
Total load
TL
7.150 kN/m
Load calculation :
Mu
kN.m
12.07
Mu/bd
N/mm2
0.08
0.06
0.05
0.03
Pt
%
###
###
120.000 mm
###
45.87 mm
HENCE SAFE
HENCE SAFE
Design of Slab
Here the aspect ratio Ly/Lx is less than 2 hence the slab is designed as a two way slab.
TwoAdjacentEdgesDisContinuous:
Basic dimensions of slab
Lx
Ly
4
6
1.500 <2
Hence designed as two way slab
15 mm
150.00 mm
130.00 mm
10 mm
20 N/mm
20
415 N/mm
d'
D
d
fck
fy
=
=
=
=
=
=
DL
FF
LL
=
=
=
3.750 kN/m
1.9 kN/m
1.5 kN/m
Total load
TL
7.150 kN/m
415
Load calculation :
Span
shorter
longer
Moment
Coefficient
Mu
kN.m
Mu/bd
N/mm2
Pt
%
x neg
0.078
13.39
0.79
###
###
156
10
200
392.70
###
x pos
0.059
10.04
0.59
###
###
156
10
200
392.70
###
y neg
0.045
7.78
0.46
###
###
156
10
200
392.70
###
y pos
0.034
5.83
0.35
###
###
156
10
200
392.70
###
F:\USER\RAM\3990\312336653.xls
RR/ST
130.000 mm
###
105.61 mm
HENCE SAFE
04/05/2016