Retaining wall work shall be taken up for a length of 10m to 20m to suit the site condition
The total height of different types of retaining wall shall be cast in 2 or 3 pours, keeping
The bottom surface shall be rammed before PCC and after completion of PCC surface
The layout of wall for the stretch to be executed will be marked on PCC and shall be got
checked by Client.
Placement and fixing of reinforcement shall be taken up with bars fabricated as per BBS
checked by Client. Laps, chairs and any other extra reinforcement that is to be provided shall be
recorded jointly in concrete pour card.
Proper cover to the reinforcement as per drawing shall be provided by adequate number
Shuttering will be carried out with plastic/film coated plywood shuttering boards.
Adequate supports will be fixed in position, Suitable shutter releasing agent will be used
Concrete pour card will be prepared and approval will be taken from Client.
Tarpaulin sheet will be kept at site to protect fresh concrete from unexpected rain.
Concrete surface will be covered with hessian cloth and cured for seven days after
concreting
Entire retaining wall shall be cast in stretches of 10m to 20m to suit site condition.
pour plan. The vertical construction joint will be provided by means of wooden stopper at 10m to
20m interval depending on length to be taken at a time.
Pouring will be done in layers and proper compaction will be ensured by using needle
vibrators. Electrically operated vibrators with different dia needles viz. 60mm or 40 mm will be
used for compaction of poured concrete depending upon the thickness of the layer.