BEAM
SUPPORT
d = 40 cm
b = 20 cm
tw = 0.8 cm
tf = 1.3 cm
r = 1.6 cm
ho = 32.8 cm
Abolt = 2.84 cm2
Ag = 23.0 cm2
Ahole = 5.40 cm2
An = 17.6 cm2
1. BEAM WEB CONTROL
1.1. BOLT SHEAR CAPACITY
Rss = Ab Fv = 4,111 kg
R = n Rss = 12,334 kg < V OK
2. FRAMING PLATE
L = 34.2 cm
t = 9 mm
NET SHEAR
Vn = 0,30(Fu Anet) = 0,30 Fu t[L - n(D + e)] e = 1.50 mm
RESUME :
PAKAI HTB. 3 M- 19
GUSSET PL. 9
3. BEAM SUPPORT
3.1. SHEAR CAPACITY for WELDING
ELECTODE F. 70 XX
Welding size = a = 6 mm
Rw = 623.6 kg/cm
F = 2 Lw Rw = 39,909 kg > OK
E. 70 XX - size 6 mm
BOLTS AND RIVETS
Bearing
TABLE 1-G. COEFFICIENTS FOR WEB TEAR-OUT
(BLOCK SHEAR)
Based on standard holes and 3-in. fastener spacing
Coefficient C1
lv lh, in.
in. 1 1 1/8 1 1/4 1 3/8 1 1/2 1 5/8 1 3/4 1 7/8 2
1 1/4 0.88 0.94 1.00 1.06 1.13 1.19 1.25 1.31 1.38
1 3/8 0.91 0.98 1.04 1.10 1.16 1.23 1.29 1.35 1.41
1 1/2 0.95 1.01 1.08 1.14 1.20 1.26 1.33 1.39 1.45
1 5/8 0.99 1.05 1.11 1.18 1.24 1.30 1.36 1.43 1.49
1 3/4 1.03 1.09 1.15 1.21 1.28 1.34 1.40 1.46 1.53
1 7/8 1.06 1.13 1.19 1.25 1.31 1.38 1.44 1.50 1.56
2 3/4 1.33 1.39 1.45 1.51 1.58 1.64 1.70 1.76 1.83
3 1.40 1.46 1.53 1.59 1.65 1.71 1.78 1.84 1.90
Coefficient C2
Bolt Dia. In.
n 3/4 7/8 1 lh
2 0.33 0.24 0.16
EB TEAR-OUT
stener spacing