DATA SHEETS FOR IEEE 14 BUS SYSTEM
he IEEE 14 bus system is shown in figure 3.1. The system data is taken
from [9]. The data given in the following tables is on 100MVA base.
The minimum and maximum limits of voltage magnitude and phase angle are
considered to be 0.95p.u. to 1.05p.u. and -45 to +45 respectively.
126
127
From
bus
1
1
2
2
2
3
4
4
4
5
6
6
6
7
7
9
9
10
12
13
To
bus
2
5
3
4
5
4
5
7
9
6
11
12
13
8
9
10
14
11
13
14
MVA
rating
120
65
36
65
50
65
45
55
32
45
18
32
32
32
32
32
32
12
12
12
Pimin
(MW )
10
20
20
Pimax
(MW )
160
80
50
ai
($/(MWhr)2 )
0.005
0.005
0.005
bi
($/MW hr)
2.450
3.510
3.890
ci
($/hr)
105.000
44.100
40.600
To bus
7
9
6
Bus
number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Generation
Real
Reactive
power
power
(MW ) (MVAR)
114.17
-16.9
40.00
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Load
Real
Reactive
power
power
(MW ) (MVAR)
0
0
21.7
12.7
94.2
19.1
47.8
-3.9
7.6
1.6
11.2
7.5
0
0
0
0
29.5
16.6
9.0
5.8
3.5
1.8
6.1
1.6
13.8
5.8
14.9
5.0
Reactive
power
limits
Qmin (MVAR) Qmax (MVAR.)
0
10
-42.0
50.0
23.4
40.0
Bus number
9
Susceptance (p.u.)
0.19
Bus voltage
Phase
Magnitude
angle
(p.u.)
(degree)
1.060
0
1.045
0
1.010
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
APPENDIX
B
DATA SHEETS FOR IEEE 30 BUS SYSTEM
he IEEE 30 bus system is shown in figure 3.3. The system data is taken
from [47]. The data given in the following tables is on 100MVA base.
The minimum and maximum limits of voltage magnitude and phase angle are
considered to be 0.95p.u. to 1.05p.u. and -45 to +45 respectively.
129
Line
number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
From
bus
1
1
2
2
2
3
4
4
5
6
6
6
6
6
8
9
9
10
10
10
10
To
bus
2
3
4
5
6
4
6
12
7
7
8
9
10
28
28
11
10
20
17
21
22
Line
number
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
From
bus
12
12
12
12
14
15
15
16
18
19
21
22
23
24
25
25
27
27
28
29
To
bus
13
14
15
16
15
18
23
17
19
20
22
24
24
25
26
27
29
30
27
30
Annual cost
(103 $/hr)
15.1125
30.2250
97.6250
179.0250
124.7750
80.6000
100.7500
146.4750
235.6000
186.000
166.2375
40.3000
65.1000
210.8000
204.600
83.7000
160.4250
90.6750
223.2000
216.6125
Bus
number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Bus voltage
Phase
Magnitude
angle
(p.u.)
(degree)
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Generation
Real
Reactive
power
power
(MW ) (MVAR)
0
0
21.7
12.7
2.4
1.2
7.6
1.6
0
0
0
0
22.8
10.9
30
30
0
0
5.919
2
0
0
11.2
7.5
0
0
6.2
1.6
8.2
2.5
3.5
1.8
9
5.8
3.2
0.9
9.5
3.4
Load
Real
Reactive
power
power
(MW ) (MVAR)
24.963
-4.638
60.97
27.677
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
37
13.949
0
0
0
0
0
0
0
0
0
0
0
0
Qmin
Reactive
power
limits
(MVAR) Qmax (MVAR)
-20
150
-20
60
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-15
44.7
0
0
0
0
0
0
0
0
0
0
0
0
Continued on next page
Bus
number
20
21
22
23
24
25
26
27
28
29
30
134
Pimin
(MW )
0
0
0
0
0
0
Pimax
(MW )
80
80
50
55
30
40
ai
bi
($/(MWhr)2 ) ($/MW hr)
0.00375
2.0000
0.01750
1.7500
0.06250
1.0000
0.00834
3.2500
0.02500
3.0000
0.02500
3.0000
ci
($/hr)
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
To bus
9
10
12
27
Susceptance (p.u.)
19
4
APPENDIX
C
DATA SHEETS FOR INDIAN UTILITY 62 BUS
SYSTEM
ndian utility 62 bus system is shown in figure 6.1. The system data is
taken from [154]. The data given in the following tables is on 100MVA
base. The minimum and maximum limits of voltage magnitude and phase
angle are considered to be 0.95p.u. to 1.1p.u. and -45 to +45 respectively.
135
Line
number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
From
bus
1
1
1
1
1
1
2
2
3
4
4
4
5
5
6
7
11
11
12
12
12
To
bus
2
4
6
9
10
14
3
6
4
5
14
15
6
8
7
8
10
16
11
13
20
Line
number
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
From
bus
13
13
14
14
14
14
16
17
20
21
22
23
23
24
24
25
25
25
27
29
30
32
To
bus
14
17
15
16
18
19
17
21
23
22
23
24
25
41
45
26
27
28
29
30
31
31
Line
number
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
From
bus
32
32
32
32
33
34
34
34
35
36
37
38
38
39
39
40
40
41
41
42
42
44
To
bus
34
36
37
46
32
33
35
37
32
46
46
34
37
37
42
30
41
42
45
43
44
59
Line
number
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
From
bus
46
47
47
48
48
49
49
51
51
51
52
52
55
56
57
57
58
58
58
59
60
60
To
bus
44
46
48
50
54
48
50
53
54
55
53
61
58
58
56
58
12
60
61
61
12
61
Bus
number
1
2
3
4
5
6
7
8
9
10
11
12
13
From
bus
61
62
MVA
rating
300
150
Generation
Real
Reactive
power
power
(MW ) (MVAR)
0
0
0
0
40
10
0
0
0
0
0
0
0
0
109
78
66
23
40
10
161
93
155
79
132
46
Load
Real
Reactive
power
power
(MW ) (MVAR)
192.649
23.554
190.581
0
0
0
0
0
255.687
0
0
0
0
0
0
0
78.202
1.218
0
0
0
0
0
0
0
0
Annual cost
(105 |/yr)
475
643
Reactive
Shunt
power
capacitor
limits (MVAR) data (MVAR)
Qmin
Qmax
Susceptance
0
450
0
0
130
0
0
5
0
0
0
0
0
255
0
0
0
0
0
0
0
0
0
0
0
100
0
0
0
0
0
0
0
0
0
0
0
0
0
Continued on next page
To
bus
62
25
Bus voltage
Phase
Magnitude
angle
(p.u.)
(degree)
1.05
0
1.05
0
1
0
1
0
1.05
0
1
0
1
0
1
0
1.05
0
1
0
1
0
1
0
1
0
Line
number
88
89
Bus
number
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Bus
number
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
Bus
number
54
55
56
57
58
59
60
61
62
144
Table C.3: Capacity and cost coefficients Indian utility 62 bus system
Generator
number
G1
G2
G3
G4
G5
G6
G7
G8
G9
G10
G11
G12
G13
G14
G15
G16
G17
G18
G19
Pimin
(MW )
50
50
50
0
50
50
50
50
0
0
50
0
50
0
0
50
0
50
100
Pimax
(MW )
300
450
450
150
300
450
200
500
600
100
150
100
300
150
500
150
100
300
600
ai
bi
(|/(MWhr)2 ) (|/MW hr)
0.0070
6.80
0.0055
4.00
0.0055
4.00
0.0025
0.85
0.0060
4.60
0.0055
4.00
0.0065
4.70
0.0075
5.00
0.0085
6.00
0.0020
0.50
0.0045
1.60
0.0025
0.85
0.0050
1.80
0.0045
1.60
0.0065
4.70
0.0045
1.40
0.0025
0.85
0.0045
1.60
0.0080
5.50
ci
(|/hr)
95
30
45
10
20
90
42
46
55
58
65
78
75
85
80
90
10
25
90
Table C.4: Transformer tap setting data Indian utility 62 bus system
From bus
1
14
4
13
12
14
14
14
48
49
47
To bus
14
15
14
14
13
19
18
16
50
50
18