Mix Design for Concrete

Grade = M 25

C1.Design stipulation:
i

Characteristic Compressive strength

ii Maximum size of aggregate

iii Degree of workability


iv Degree of quality
v Type of Exposure

=
=
=

C2. Test data for materials


(i) Cement used

25
20
0.8
Good
Mild
PPC

(ii) Specific gravity of Cement


(iii) Specific gravity
Fine Aggregate

Coarse Aggregate
(iv) Water absorption
Fine Aggregate

2.8
2.61

Coarse Aggregate
(v) Free Surface Moisture
Fine Aggregate
Coarse Aggregate

(vi) Fine Aggregate confirming the table 4,


383- Zone

IS

N/mm2
mm

2.1
0.78

%
%

=
=

2.1

31.60

0.44

(From fig. 1, Is 10262)

=
=

% (From Table 3, IS 10262)


0.98 Cum

%
Nil %
Zone

C3.Target mean strength


N/mm2

C4. Selection of Water Cement ratio


Water Cement ratio
C7. Determination of Fine & Coarse aggregate
Air entrapped in concrete
Actual quantity of concrete "V"

Materials required for concrete


Grade M 25
1
Concrete quantity
=
Sl.
No

Material name

Cum

Quantity

Unit

1 Cement

422.73

kg

2 Fine Aggregate

565.72

kg

3 Coarse Aggregate 20mm

709.71

kg

4 Coarse Aggregate 10mm

473.14

kg

5 Water

183.63

ltr

6 Slump

75 - 100

7 W/C ratio

0.44

mm

Prepared by,

Sathiyaseelan
+91 8894770272