Huawei NE40E Router Quick Ordering Guide

Product Overview
The NetEngine40E series universal service router (NE40E) is a family of high-end
network products that are usually deployed at the edges of Internet Protocol (IP)
backbone networks, IP Metropolitan Area Networks (MANs), and other large-scale IP
networks. The NE40E, ME60, NE20E-S and NE5000E together provide a complete,
layered IP network solution.
The NE40E can be flexibly deployed at the edge or core of IP or MPLS networks,
simplifying the network structure. With its ability to provide an extensive range of services
with reliable service quality, the NE40E is enabling IP and MPLS bearer networks to
develop greater broadband capacity and to become more secure, intelligent, and
service-oriented. Based on distributed hardware forwarding and non-blocking switching
technologies, the NE40E features line-rate forwarding capability, a well designed Quality
of Service (QoS) mechanism, strong service processing capability, and excellent
expansibility. The NE40E is based on a 400G platform and provides 100G line cards to
satisfy increased demand for bandwidth. Compatible with all line cards currently in use,
the NE40E minimizes the need for additional investments.
Ordering
NE40E Router Configuration Flow: Basic Configuration -Services BoardsSpecial
Service BoardsSoftware, LicenseElectrical or Optical Modules Cabinet
Cables Accessories

1 Basic Configuration
1Chassiswith power
Select a chassis based on the number of service boards
required.
BOM Number

SBOM Type

Description

Main

Switc

Servic

Power

Maximum Power

Control

hing

Slots

Consumption

Slots
02351596

NetEngine40E-X3,C
CR52-BKPE-4
U-DC

02351597
CR52-BKPE-5
U-AC

<=1100W

R5Z1BKPE,Integrate
d

DC

In the

Chassis

chass

Components(NE40E
-X3)-4U

1+1

NetEngine40E-X3,C

Backup

R5Z2BKPE,Integrate
d

AC

Chassis

Components(NE40E
-X3)-5U

is, no
need
to
config
ure

<=1100W

02351930

NetEngine40E,CR5Z
CR5B0BKP08
70

1BKP08A,NE40E-X8
Integrated

Chassis

Components(Includi

<=3300W

1+1

Backup

ng 4 DC Power)
02351931

NetEngine40E,CR5Z
CR5B0BKP16
70

1BKP16A,NE40E-X1
6 Integrated Chassis
Components(Includi

<=6500W

1+1

16

Backup

ng 8 DC Power)-32U
02400376

CR5B0PWRB
X60

Power Distribution
Cabinet,220V,50/60
HZ,72000mA,None,
EPS200-4850A

NE40E-X8/X16 AC must configure1 for X82 for X16

02130872

WPSU50A00

Power
module--33degC-65
degC-90VAC-290VA
C-(-53.5)VDC/54.2AAC/DC rectifier

NE40E-X8/X16 AC must configure4 for X88 for X16

04080076

None

Monitor and Alarm


Cable,3m,D9M,CC4
P0.48B(S),D9M

NE40E-X8/X16 AC must configure1 for X82 for X16

2Main control and SFUSelect a main control board according to the chassis,
bandwidth and backup requirements.
BOM

SBOM Type

Description

Number

Applicable

Backup

Remarks

Chassis

03030KKR

CR52-MPUD

03054206

CR5D0MPUD
170

03030KSR
CR5D0SRUA4
70

NetEngine40E,CR5
2MPUD0,Main
Processing
Unit
D(Including
1*2G
Memory and 1*1G
CF Card)

NetEngine40E,CR5
2MPUD2,Main
Processing
Unit
D2(Including
2G
Memory and 2G
USB)
NetEngine40E,CR5
7SRU40A4,Switch
and
Route
Processing
Unit

1:1

Mandatory and not preferred.


Each device is configured with
one MPUD or two MPUDs.
Memory cards and CF cards need
to be prepared additionally. Each
MPUD can be configured with two
CF cards and one DDR2 memory
card.

1:1

Mandatory and preferred. Each


device is configured with 1 or 2
pcs. It contains a 2 G DDR3
memory card and a 2 G EUSB,
which
are
not
quoted
independently. It is supported only
in V6R5C00 and later versions.

1:1

Not preferred. It supports only 40


G LPUs. Each device is
configured with one or two pcs. It
can be configured with two CF

NE40E-X3

NE40E-X3

NE40E-X8

A4(Including 1*2G
Memory and 1*1G
CF Card)

cards, two DDR2 memory cards,


and two USB disks. By default, it
contains one 1 GB CF card and
one 2 GB memory card. The other
CF card, memory card, and USB
disks need to be prepared and
quoted additionally.
1:1

03053549

CR5D0SRUA5
70

03030KSY

CR5DSFUI407
C

03053548
CR5DSFUIE0
7C

NetEngine40E,CR5
7SRU200A5,Switch
and
Route
Processing
Unit
A5(Including
One
2G Memory and
One 1G CF Card)

NetEngine40E-CR5
7SFU40C0-40Gbps
Switch Fabric Unit C
NetEngine40E-CR5
7SFU200C0-200Gb
ps Switch Fabric
Unit C

NE40E-X8

2+1
NE40E-X8

NE40E-X8

1:1

CR5D0MPUB
460

03030KSX

CR5DSFUI407
B

03053547

Not preferred

2+1

03030JTW

CR5DSFUIE0
7B

NetEngine40E,CR5
6MPUB4,Main
Processing
Unit
B4(Including 1*2G
Memory and 1*1G
CF Card)

NetEngine40E-CR5
7SFU40C0-40Gbps
Switch Fabric Unit B
NetEngine40E-CR5
7SFU200B0-200Gb

Preferred. It is optional for


supporting 100 Gbit/s LPUs and
supported in V600R003 or later
versions. Each device is equipped
with one or two pcs. It can be
configured with two CF cards, two
DDR2 memory cards, and two
USB disks. By default, it contains
one 1 GB CF card and one 2 GB
memory card. The other CF cards,
memory card, and USB disks
need to be prepared and quoted
additionally.

NE40E-X1
6

NE40E-X1

Mandatory and preferred. Each


device is configured with one
MPUD or two MPUB4s. Each
MPUB4 can be configured with
two CF cards, two DDR2 memory
cards, and two USB disks. By
default, each MPUB4 is attached
with one 1 GB CF card and one 2
GB memory card. The other CF
card, memory card, and USB
disks need to be prepared and
quoted additionally.

3+1

Not preferred

6
NE40E-X1

Preferred. It is used to replace the


SFU with the BOM number as
03030KSY.

3+1

Preferred. It is used to replace the


03030KSX. It is optional for

ps Switch
Unit B

Fabric

supporting 100 Gbit/s LPUs and


mandatory for supporting 200
Gbit/s LPUs. It is used together
with
the
SRU200A5
and
supported in V600R003C00 or a
later version.

3CF Card, Memory card and USB Disks


Configuration notes of the CF card, memory card and USB disks
BOM Number

SBOM Type

Model

Description

Remarks

02315064

CF-512M

CF Card

512 MB CF card

Mandatory.

02316042

CF-1G

CF Card

1 GB CF card

Mandatory.

02315063

MEM-1G-184pin

Memory

MEM-1G-184pin

It is mandatory and of DDR

Card
SDRAM type. This type of
memory cards is applied to
the MPUs on the NE40E-X3
and NE40E-X16 and SRU on
the NE40E-X8.
02316431

MEM-2G-240pin

Memory
Card

2GB 240pin
memory module

It is mandatory and of DDR2


SDRAM type. This type of
memory cards is applied to
the MPUs on the NE40E-X3
and NE40E-X16 and SRU on
the NE40E-X8.

06010171

NUSBDSK01

USB Disk

Storage,

USB

disk,4GB/USB2.0

Optional. It is applied to the


SRU40A4 on the NE40E-X8
and

the

MPUB4

of

the

NE40E-X16.

NE40E-X3
The CR52MPUD (03030KKR) of the NE40E-X3 can be configured with two CF cards
and the maximum capacity of a single CF card can be 1 GB.
By default, the CR52MPUD is already attached with one 1 GB CF card. During

configuration, you must configure another CF card. The CF card with the BOM number
being 02316042 is recommended.
The CR52MPUD2 contains CF cards. Customers do not need to purchase
additionally.
The CR52MPUD (03030KKR) of the NE40E-X3 has one memory slot and supports
single DDR2 memory cards of a maximum of 2 GB.
By default, the CR52MPUD is already attached with a 2 GB memory card. You do not
need to purchase the memory card independently during the contract configuration.
The CR52MPUD2 contains 2 GB DDR3 memory cards. Customers do not need to
purchase additionally.
CR52-MPUD does not support USB disks. CR5D0MPUD170 supports 2G USB and it
is contained and need not to be configured.
NE40E-X8
The CR57SRU40A4 (03030KSR) of the NE40E-X8 can be configured with two CF
cards and the maximum capacity of a single CF card can be 1 GB.
By default, the CR57SRU40A4 is already attached with one 1 GB CF card. During
configuration, you must configure another CF card. The CF card with the BOM number
being 02316042 is recommended.
he CR57SRU40A4 (03030KSR) of the NE40E-X8 supports 2 GB DDR2 SDRAM
memory cards and can be configured with a maximum of two such memory cards. The
CR57SRU40A4 is already attached with one 2 GB memory card.
It is recommended that the CR57SRU40A4 be configured with another memory card
of the BOM number 02316431 during the contract configuration.
The CR57SRU40A4 (03030KSR) of the NE40E-X8 supports two USB2.0 interfaces.
Each SRU40A4 supports a maximum of two USB disks, and each NE40E-X8 supports a
maximum of four USB disks. By default, no USB disk is configured. How many USB disks
(06010161 or 06010171) needs to be configured depend on customers' requirements.
The USB disk is used to upgrade the system software package. It is recommended that
each device be configured with one USB disk. After the upgrade, you need to copy the
system software package to the CF card.

NE40E-X16
The CR56MPUB4 (03030JTW) of the NE40E-X16 can be configured with two CF
cards and the maximum capacity of a single CF card can be 1 GB.
By default, the CR56MPUB4 is already attached with one l GB CF card. During
configuration, you must configure another CF card. The CF card with the BOM number as
02316042 is recommended.
The CR56MPUB4 (03030JTW) of the NE40E-X16 supports 2 GB DDR2 SDRAM
memory cards and can be configured with a maximum of two such memory cards. The
CR56MPUB4 is already attached with one 2 GB memory card.
It is recommended that the CR56MPUB4 be configured with another memory card of
the BOM number 02316431 during the contract configuration.
In 1:1 mode of MPUs or SRUs, the capacity of the memory cards of the MPUs or
SRUs must be the same. The memory cards configured for one board must share the
same BOM number, and it is better to have them supplied by the same manufacturer.
The CR56MPUB4 (03030JTW) of the NE40E-X16 supports two USB2.0 interfaces.
Each MPUB4 supports a maximum of two USB disks, and each NE40E-X16 supports a
maximum of four USB disks. By default, no USB disk is configured. You can determine the
number of USB disks with the BOM number being 06010161 or 06010171 according to
customers' requirements. The USB disk is used to upgrade the system software package.
It is recommended that each device be configured with one USB disk. After the upgrade,
you need to copy the system software package to the CF card.

2 Service Slots
1Configuration Notes of the LPUF-10: The LPUF-10 (03038461) is a 10 Gbit/s
platform for flexible cards. It provides four slots for flexible cards of the same type or
different types, and supports hot swap of flexible cards. The LPUF-10 supports a
maximum of 10-Gbit/s bandwidth. When the total bandwidth of ports in the four slots
exceeds 10 Gbit/s, the line-rate forwarding performance is not ensured.
BOM Number
03038461

SBOM Type
CR53-LPUF-10

Description
Flexible Card Line Processing
Unit(LPUF-10,four slots)

Remarks
The LPUF-10 (03038461) is a 10 Gbit/s
platform for flexible cards. It provides four
slots for flexible cards of the same type or

different types, and supports hot swap of


flexible cards.
03030FSL

CR53-P10-1xPOS
/STM64-XFP

1-Port OC-192c/STM-64c
POS-XFP Flexible
Card(Occupy two slots)

Each flexible card occupies two subcard


slots on the LPUF-10. It is strongly
recommended that only P1XX be
configured for each LPUF-10. The XFP
optical module needs to be prepared
additionally and each LPUF-10 can be
configured with a maximum of one XFP
optical module.

03030EYA

CR53-P10-8x100/
1000Base-X-SFP

8-Port 100/1000Base-X-SFP
Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-10.
The SFP optical module needs to be
prepared additionally and each LPUF-10
can be configured with a maximum of eight
SFP optical modules. All interfaces support
the sending of Ethernet synchronous clock
signals and meanwhile only the interface
0/1 supports the receiving of Ethernet
synchronous clock signals.
SFP optical modules with electrical
interfaces can be inserted into the
interfaces of each flexible card.

03030GBV

CR53-P10-1xPOS
/STM16-SFP

1-Port OC-48c/STM-16c
POS-SFP Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-10.
The SFP optical module needs to be
prepared additionally and each LPUF-10
can be configured with a maximum of one
SFP optical module.

03030GUG

CR53-P10-2xATM
/STM4-SFP

2-Port OC-12c/STM-4c
ATM-SFP Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-10.
The SFP optical module needs to be
prepared additionally and each LPUF-10
can be configured with a maximum of two
SFP optical modules.

03030GBR

CR53-P10-4xATM
/STM1-SFP

4-Port OC-3c/STM-1c
ATM-SFP Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-10.
The SFP optical module needs to be
prepared additionally and each LPUF-10
can be configured with a maximum of four
SFP optical modules.

03030HNJ

CR53-P10-2xPOS
/STM16-SFP

2-port OC-48c/STM-16c
POS-SFP Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-10. The SFP optical
module needs to be prepared additionally
and each LPUF-10 can be configured with
a maximum of two SFP optical modules.

03030JCX

CR53-P10-4xPOS
/STM16-SFP

4-port OC-48c/STM-16c
POS-SFP Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-10.
The SFP optical module needs to be
prepared additionally and each LPUF-10
can be configured with a maximum of four
SFP optical modules.

03030JCY

CR53-P10-4xPOS
/STM4-SFP

4-port OC-12c/STM-4c
POS-SFP Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-10.
The SFP optical module needs to be
prepared additionally and each LPUF-10
can be configured with a maximum of four

SFP optical modules.


03030JTY

CR53-P10-4xPOS
/STM1-SFP

4-port OC-3c/STM-1c
POS-SFP Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-10.
The SFP optical module needs to be
prepared additionally and each LPUF-10
can be configured with a maximum of four
SFP optical modules.

03030JUB

CR53-P10-8xPOS
/STM4-SFP

8-port OC-12c/STM-4c
POS-SFP Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-10.
The SFP optical module needs to be
prepared additionally and each LPUF-10
can be configured with a maximum of eight
SFP optical modules.

03030JUA

CR53-P10-8xPOS
/STM1-SFP

8-port OC-3c/STM-1c
POS-SFP Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-10.
The SFP optical module needs to be
prepared additionally and each LPUF-10
can be configured with a maximum of eight
SFP optical modules.

03030KBB

03030HNE

CR53-P10-2xcPO
S/STM1-SFP

CR53-P10-4xE3/c
T3-SMB

2-Port Channelized
OC-3c/STM-1c POS-SFP
Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-10.

4-Port Clear Channel


E3/Channelized T3-SMB
Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-10.

The SFP optical module needs to be


prepared additionally and each LPUF-10
can be configured with a maximum of two
SFP optical modules.

Coaxial cables are used as user cables.

03030KHP

CR53-P10-24xcE
1/cT1-DB100

24-Port Channelized
E1/T1-DB100 Flexible Card
(Supporting 1588v2)

Each flexible card occupies one subcard


slot on the LPUF-10 and needs to be
connected to a conversion box through the
cable (04070064). If the cable is a coaxial
cable with SMB connectors, the conversion
box (02351608) is used. If the cable is a
twisted-pair cable with RJ48 connectors,
the conversion box (02351606 or
02351607) is used.

03030KNE

CR5M0E8GFA30

8-Port 100/1000Base-X-SFP
Flexible Card
A(P10-A,Supporting 1588v2)

Each flexible card occupies one subcard


slot on the LPUF-10.
The SFP optical module needs to be
prepared additionally and each LPUF-10
can be configured with a maximum of eight
SFP optical modules.
SFP optical modules with
10M/100M/1000M electrical interfaces can
be inserted into the interfaces of each
flexible card.
In addition to IEEE 1588v2, all interfaces
support the sending and receiving of
Ethernet synchronous clock signals.

02351606

DB100-24xRJ48E1/T1-Box

24*E1/T1 DB100 to RJ48 Port


Conversion Box

Each flexible card (03030KHP) is


configured with one conversion box.

02351607

DB100-48xRJ48E1/T1-Box

48*E1/T1 DB100 to RJ48 Port


Conversion Box

Every two flexible cards (03030KHP) are


configured with one conversion box.

02351608

DB100-24xSMB-E

24*E1 DB100 to SMB Port

Each flexible card (03030KHP) is

04070064

1-Box

Conversion Box

configured with one conversion box.

DB100-DB100-Ca
ble-4m

Signal cable ,24E1 Transit


Cable,4m,D100M-I,3*CC16P0.
4P430U(S)-I,D100M-I

Each flexible card (03030KHP) is


configured with one cable.

2 Configuration Notes of the LPUF-21: The LPUF-20 and LPUF-21 are newly
increased in NE80E/40E V300R003. Adopting the SD588 processors, the LPUF-20 and
LPUF-21 are 20 Gbit/s platforms for flexible cards and support a maximum bandwidth of
20 Gbit/s. When the total bandwidth of the interfaces on the LPUF-20 and LPUF-21 in two
slots exceeds 20 Gbit/s, the line-rate forwarding performance is not ensured on all
interfaces. The LPUF-20/21 provides two slots for flexible cards of the same type or
different types. According to the support for hot swap of the flexible card, the LPUF-20 can
be classified into the LPUF-20 supporting hot swap (03030HVN and 02316416) and the
LPUF-20 that does not support hot swap (02315504 and 02315756). The LPUF-21
supports hot swap of the flexible card.
In the case of the LPUF-20 that does not support hot swap of the flexible card, before
installing the LPUF-20, you need to first insert flexible cards into the LPUF-20, and before
removing flexible cards, you need to first remove the LPUF-20. In the case of the LPUF-20
that supports hot swap of the flexible card and the LPUF-21, you can install the
LPUF-20/21 and insert or remove the flexible cards in any order. The LPUF-20/-21-A
supports services such as L3VPN, MVPN, and enhanced IPV6.
BOM Number
03030KJY

03053989

SBOM Type
CR52-LPUF-21-A

CR5DLPUF202E

Description

Remarks

Flexible Card Line


Processing Unit(LPUF-21,2
sub-slots) A
(L3VPN,MVPN,IPV6
Enhanced)

Supports hot swap of the flexible card and


is preferred.

Flexible Card Line


Processing Unit(LPUF-21,2
sub-slots) E

Supports hot swap of subcards.

Supports services such as L3VPN,


MVPN, and enhanced IPV6.
Supports full-width and half-width flexible
cards.

Supports services such as L3VPN,


MVPN, and IPV6 enhanced.
Supports both half-width subcards and
full-width subcards.
Supports the traffic management function.
Supports PPPoE users access.
The board is supported since
V600R005C00.

03030GSG

CR52-P20-12x10/100/
1000Base-TX-RJ45

12-Port
10/100/1000Base-RJ45
Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-20/21.

03030GSK

CR52-P20-1x10GBas
e WAN/LAN-XFP

1-Port 10GBase
WAN/LAN-XFP Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-20/21.
The XFP optical module needs to be
prepared additionally and each
LPUF-20/21 can be configured with a
maximum of one XFP optical module.
It supports the sending and receiving of

Ethernet synchronous clock signals.


03030GSH

CR52-P20-12x100/10
00Base-X-SFP

12-Port 100/1000Base-SFP
Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-20/21.
The SFP optical module needs to be
prepared additionally and each
LPUF-20/21 can be configured with a
maximum of 12 optical modules. All
interfaces support the sending of Ethernet
synchronous clock signals and
meanwhile only the interface 0/1 supports
the receiving of Ethernet synchronous
clock signals.
SFP optical modules with
10M/100M/1000M electrical interfaces
can be inserted into the interfaces of each
flexible card.

03030HND

CR52-P20-1xPOS/ST
M64-XFP

1-Port OC-192c/STM-64c
POS-XFP Flexible Card

Each flexible card occupies one subcard


slot on the LPUF-20/21.
The XFP optical module needs to be
prepared additionally and each
LPUF-20/21 can be configured with a
maximum of one XFP optical module.

03030JUJ

CR52-P21-40x10/100/
1000Base-TX-RJ45

40-Port
10/100/1000Base-RJ45
Flexible Card(Occupy two
sub-slots)

It can be inserted into only the LPUF-21


and each flexible card occupies two
subcard slots on the LPUF-21.

03030JUL

CR52-P21-40x100/10
00Base-X-SFP

40-Port 100/1000Base-SFP
Flexible Card(Occupy two
sub-slots)

It can be inserted into only the LPUF-21


and each flexible card occupies two
subcard slots on the LPUF-21.
The SFP optical module needs to be
prepared additionally and each
LPUF-20/21 can be configured with a
maximum of 40 SFP optical modules. All
interfaces of the flexible card support the
sending of Ethernet synchronous clock
signals but each time only one interface
supports the receiving of Ethernet
synchronous clock signals. The interface
supporting the receiving of Ethernet
synchronous clock signals is selected
through software among the 40 interfaces
on the flexible card.
SFP optical modules with
10M/100M/1000M electrical interfaces
can be inserted into the interfaces of each
flexible card.

03030JUK

CR52-P21-4x10GBas
e WAN/LAN-XFP

4-port 10GBase
WAN/LAN-XFP Flexible
Card(Occupy two sub-slots)

It can be inserted into only the LPUF-21


and each flexible card occupies two
subcard slots on the LPUF-21.
The XFP optical module needs to be
prepared additionally and each
LPUF-20/21 can be configured with a
maximum of four XFP optical modules. All
interfaces of the flexible card support the
sending of Ethernet synchronous clock
signals but each time only one interface
supports the receiving of Ethernet
synchronous clock signals. The interface
supporting the receiving of Ethernet
synchronous clock signals is selected

through software among the four


interfaces on the flexible card.
03030FDY

CR52-P20-48x10/100
Base-TX-RJ45

2-Port 10GBase
LAN/WAN-XFP+20-Port
100/1000Base-X-SFP
Flexible Card(P20,Occupy
two sub-slots)

It can be inserted into only the LPUF-21


and each flexible card occupies two
subcard slots on the LPUF-21.
The XFP and SFP optical modules need
to be prepared additionally and each
LPUF-20/21 can be configured with a
maximum of 2 XFP optical modules and
20 SFP optical modules.
All interfaces support the sending of
Ethernet synchronous clocks and
meanwhile only one interface supports
the receiving of Ethernet synchronous
clocks through software.
SFP optical modules with
10M/100M/1000M electrical interfaces
can be inserted into the interfaces of each
flexible card.

03030KKP

CR52-P20-12x100/10
00Base-X-SFP-A

1-Port 10GBase
WAN/LAN-XFP Flexible Card
A(Supporting 1588v2)

Each flexible card occupies one subcard


slot on the LPUF-20/21. Interfaces on the
flexible card support the sending and
receiving of Ethernet synchronous clocks
and IEEE 1588v2. The XFP optical
module needs to be prepared additionally
and each LPUF-20/21 can be configured
with a maximum of one XFP optical
module.

03030KKQ

CR5ML2XEEG20

12-Port 100/1000Base-SFP
Flexible Card A(Supporting
1588v2)

Each flexible card occupies one subcard


slot on the LPUF-20/21.
The SFP optical module needs to be
prepared additionally and each
LPUF-20/21 can be configured with a
maximum of 12 SFP optical modules.
SFP optical modules with
10M/100M/1000M electrical interfaces
can be inserted into the interfaces of each
flexible card.
All interfaces support the sending of
Ethernet synchronous clocks and
meanwhile only one interface supports
the receiving of Ethernet synchronous
clocks through software.
All interfaces support IEEE 1588v2.

03030HVJ

03030HVH

12-Port
100/1000Base-X-SFP
Flexible Card B(P20-B)

Each flexible card occupies one subcard


slot on the LPUF-21 and supports PPPoE
and IPoE. The SFP optical module needs
to be prepared additionally and each
LPUF-21 can be configured with a
maximum of 12 SFP optical modules.
SFP optical modules with
10M/100M/1000M electrical interfaces
can be inserted into the interfaces of each
flexible card.

1-Port 10GBase
LAN/WAN-XFP Flexible Card
B(P20-B)

Each flexible card occupies one subcard


slot on the LPUF-21 and supports PPPoE
and IPoE. The XFP optical module needs
to be prepared additionally and each
LPUF-21 can be configured with a
maximum of one XFP optical module.

CR5M0EBGFB20

CR5M0L1XXB20

03030LVG

03030LVF

CR5M0L1XXE20

1-Port 10GBase
LAN/WAN-XFP Flexible Card
E(P20-E)

Each flexible card occupies one subcard


slot on the LPUF-21 and supports
downstream TM. The XFP optical module
needs to be prepared additionally and
each LPUF-21 can be configured with a
maximum of one XFP optical module.

10-Port 1000Base-X-SFP
Flexible Card E(P20-E)

Each flexible card occupies one subcard


slot on the LPUF-21 and supports
downstream TM.
The XFP optical module needs to be
prepared additionally and each LPUF-21
can be configured with a maximum of 10
XFP optical modules. XFP optical
modules with 1000M electrical interfaces
can be inserted into the interfaces of each
flexible card.

CR5M0EAGFE20

3Configuration Notes of the LPUF-40: The LPUF-40 is a 40 Gbit/s platform for flexible
cards and supports a maximum bandwidth of 40 Gbit/s. The LPUF-40 provides two slots
for flexible cards of the same type or different types, and supports hot swap of the flexible
card.
The LPUF-40-A supports services such as L3VPN, MVPN, and enhanced IPV6.
BOM Number

SBOM Type

03030KWD
CR5MLPUF402A

03053990

Description

Remarks

Flexible Card Line


Processing Unit(LPUF-40,2
sub-slots) A
(L3VPN,MVPN,IPv6
Enhanced)

Supports hot swap of the flexible card and


is preferred.

Flexible Card Line


Processing Unit(LPUF-40,2
sub-slots) E

Supports hot swap of subcards.

CR5DLPUF402E

Supports services such as L3VPN,


MVPN, and enhanced IPV6.

Supports services such as L3VPN,


MVPN, and IPV6 enhanced.
Supports the traffic management function.
Supports PPPoE users access.
The board is supported since
V600R005C00.

03036967

CR5M00EEGF20

20-Port
100/1000Base-X-SFP
Flexible Card(P40)

Each flexible card occupies one subcard


slot on the LPUF-40.
All interfaces support the sending of
Ethernet synchronous clocks and
meanwhile only one interface supports
the receiving of Ethernet synchronous
clocks through software.
The SFP optical module needs to be
prepared additionally and each LPUF-40
can be configured with a maximum of 20
SFP optical modules.
SFP optical modules with
10M/100M/1000M electrical interfaces
can be inserted into the interfaces of each
flexible card.
The 100M SFP optical module is
supported and a maximum of 20 100M
SFP optical modules can be inserted into

each flexible card.


03037070

CR5M0EEGFA20

20-Port
100/1000Base-X-SFP
Flexible Card
A(P40-A,Supporting 1588v2)

Each flexible card occupies one subcard


slot on the LPUF-40.
All interfaces support the sending of
Ethernet synchronous clocks and
meanwhile only one interface supports
the receiving of Ethernet synchronous
clocks through software.
The SFP optical module needs to be
prepared additionally and each LPUF-40
can be configured with a maximum of 20
SFP optical modules.
SFP optical modules with
10M/100M/1000M electrical interfaces
can be inserted into the interfaces of each
flexible card. All interfaces on the flexible
card support IEEE 1588v2.
The 100M SFP optical module is
supported and a maximum of 20 100M
SFP optical modules can be inserted into
each flexible card.

03036752

CR5M00L2XX20

2-Port 10GBase
LAN/WAN-XFP Flexible
Card(P40)

Each flexible card occupies one subcard


slot on the LPUF-40.
All interfaces support the sending of
Ethernet synchronous clocks and
meanwhile only one interface supports
the receiving of Ethernet synchronous
clocks through software.
The XFP optical module needs to be
prepared additionally and each LPUF-40
can be configured with a maximum of two
XFP optical modules.

03038466

CR5M0L2XXA20

2-Port 10GBase
LAN/WAN-XFP Flexible Card
A(P40-A,Supporting 1588v2)

Each flexible card occupies one subcard


slot on the LPUF-40.
All interfaces support the sending of
Ethernet synchronous clocks and
meanwhile only one interface supports
the receiving of Ethernet synchronous
clocks through software.
The XFP optical module needs to be
prepared additionally and each LPUF-40
can be configured with a maximum of two
XFP optical modules.
All interfaces on the flexible card support
IEEE 1588v2.

03030MDK

CR5M0L2XXB20

2-Port 10GBase
LAN/WAN-XFP Flexible Card
B(P40-B,Supporting PPPoE
and IPoE)

Each flexible card occupies one subcard


slot on the LPUF-40 and supports PPPoE
and IPoE.
The XFP optical module needs to be
prepared additionally and each LPUF-40
can be configured with a maximum of two
XFP optical modules.
The flexible card is supported in
V600R002C02 and later versions.

03030MDS

CR5M0EEGFB20

20-Port
100/1000Base-X-SFP
Flexible Card
B(P40-B,Supporting PPPoE

Each flexible card occupies one subcard


slot on the LPUF-40 and supports PPPoE
and IPoE.
The SFP optical module needs to be

and IPoE)

prepared additionally and each LPUF-40


can be configured with a maximum of 20
SFP optical modules.
SFP optical modules with
10M/100M/1000M electrical interfaces
can be inserted into the interfaces of each
flexible card.
The 100M SFP optical module is
supported and a maximum of 20 100M
SFP optical modules can be inserted into
each flexible card.
The flexible card is supported in
V600R002C02 and later versions.

03030MLA
CR5D00EEGE70

20-Port
10/100/1000Base-RJ45
Flexible Card(P40)

Each subcard requires an LPUF-40


subcard slot.

Each subcard requires an LPUF-40


subcard slot.

CR5D00L4XX70

4-Port 10GBase
LAN/WAN-XFP Flexible
Card(P40,Occupy one
sub-slot)

03030LXH

The board is supported by NE40E since


V600R005C00.

At most four XFP optical modules can be


configured additionally for each card.
The board is supported by NE40E since
V600R005C00.

03030LYU

20-Port 1000Base-X-SFP
Flexible Card E(P40-E)

Each subcard requires an LPUF-40


subcard slot. Supports traffic control
management.
The SFP optical module is required
additionally. At most 20 SFP optical
modules can be configured for each
subcard.
SFP modules with electrical interfaces
can be configured. SFP modules with
10M/100M/1000M electrical interfaces
can be inserted into ports. The LPUF-40
board with 5A configuration can be
equipped with 10 electrical interface SFP
modules at most. The LPUF-40 board
with 7A configuration supports full 20
electrical interface SFP modules.

CR5D0EEGFE70

The 100M SFP optical module is


supported and each subcard can be
installed with 20 100M SFP optical
modules.
The board is supported by NE40E since
V600R005C00.
03030MGC

2-Port 10GBase
LAN/WAN-XFP Flexible Card
E(P40-E)
CR5D0L2XXE70

Each subcard requires an LPUF-40


subcard slot. Supports traffic control
management.
At most two XFP optical modules can be
prepared additionally for each card.
The board is supported by NE40E since
V600R005C00.

4Configuration Notes of the LPUF-100: The LPUF-100 is a 100G flexible card platform
and supports a maximum bandwidth of 100 Gbit/s.The LPUF-100 provides four subcard

slots and supports the mixed configuration of subcards of various types. In addition, the
LPUF-10 supports hot swap of subcards.
The LPUF-100 supports services such as L3VPN, MVPN, and IPV6 enhanced.
BOM Number

SBOM Type

03053589
CR5DLPUFA070

03030MXM

CR5D0L5XXA70

Description

Remarks

NetEngine40E,CR57LPUF10
1A0,100Gbps Flexible Card
Line Processing
Unit(LPUF-100,4 sub-slots)

Provides four subcard slots and supports


the hot swap of subcards. Preferred;

5-Port 10GBase
LAN/WAN-XFP Flexible Card
A(P100-A,Supporting
1588v2,Occupy two
sub-slots)

It occupies two LPUF-100 subcard slots.

Supports services such as L3VPN,


MVPN, and IPV6 enhanced.

The XFP optical module is required


additionally. At most five XFP optical
modules can be installed on each board.
All interfaces support 1588v2.
The board is supported by NE40E since
V600R003.

03030MXA

CR5D00EMGF72

48-Port
100/1000Base-X-CSFP
Flexible Card(P100,Occupy
two sub-slots)

It occupies two LPUF-100 subcard slots.


The CSFP single-fiber bidirectional
optical module(34060525)is required
additionally. At most 24 CSFP single-fiber
bidirectional optical modules can be
installed on each board.
The board is supported by NE40E since
V600R003.

03030NCF

CR5D00EFGF70

24-Port
100/1000Base-X-SFP
Flexible Card(P100,Occupy
two sub-slots)

It occupies two LPUF-100 subcard slots.


The SFP optical module is required
additionally. At most 24 SFP optical
modules can be installed on each board.
SFP modules with 10M/100M/1000M
electrical interfaces can be installed on
the subcard.
Supported by V600R003 and later
versions. The board is supported by
NE40E since V600R003.

03030MXC

CR5D0L5XFB70

5-Port 10GBase
LAN/WAN-SFP+ Flexible
Card B(P100-B,Occupy two
sub-slots)

It occupies two LPUF-100 subcard slots.


SFP+ optical module is required
additionally. At most five SFP+ optical
modules can be installed on each board.

03030MXN

CR5D00P1MZ70

1-Port OC-768c/STM-256c
POS-2KM-LC Flexible
Card(P100,2 sub-slots)

No need SFP modules.

03030MXQ

CR5D00P2XX70

2-Port OC-192c/STM-64c
POS-XFP Flexible
Card(P100,Occupy one
sub-slot)

It occupies one LPUF-100 subboard slot.


XFP optical modules need to be
configured additionally and it can be
equipped with a maximum of two XFP
optical modules.
The subboard needs to be configured
with guide rails and blank fillers.
BOM No. of the 1/4-width blank filler:
21136332
BOM number of the guide rail: 21122042

55.5.5 Configuration Notes of the LPUI: The integrated LPU is not a flexible LPU. The
integrated LPU includes the 100G LPUI-100 and 40G LPUI-41.

BOM Number
03053481

03053480

03053421

03053422

03053423

SBOM Type
CR5D0LAXXA70

CR5D00EDXF70

CR5D00L8XX70

CR5D00L4XX71

CR5D00EMGF70

Description

Remarks

NetEngine40E,CR57L5XFA0
,5-Port 10GBase
LAN/WAN-SFP+ Flexible
Card B(P100-B,Occupy two
sub-slots)

The line-rate forwarding capability is 100


Gbit/s;

NetEngine40E,CR57EDXFB
0,16-Port 10GBase
LAN-SFP+ Integrated Line
Processing Unit (LPUI-100)

Converge the 160G board to the 80G


board;

NetEngine40E,CR57L8XXB0
,8-Port 10GBase
LAN/WAN-XFP Integrated
Line Processing Unit
(LPUI-41)

The line-rate forwarding capability is 40


Gbit/s;

NetEngine40E,CR57L4XXB0
,4-Port 10GBase
LAN/WAN-XFP Integrated
Line Processing Unit
(LPUI-41)

The line-rate forwarding capability is 40


Gbit/s;

NetEngine40E,CR57EMGFB
0,48-Port
100/1000Base-X-SFP
Integrated Line Processing
Unit (LPUI-41)

The line-rate forwarding capability is 50


Gbit/s;

The XFP optical module is required


additionally. At most 10 XFP optical
modules can be installed on each board.

The SFP+ optical module is required


additionally. At most 16 SFP+ optical
modules can be installed on each board.

The XFP optical module is required


additionally. At most eight XFP optical
modules can be installed on each board.

The XFP optical module is required


additionally. At most four XFP optical
modules can be installed on each board.

The SFP optical module is required


additionally. At most 48 SFP optical
modules can be installed on each board.
SFP modules with 10M/100M/1000M
electrical interfaces can be installed on
the subcard.
The CR57EMGFB0 supports 100M SFP
optical modules and each board can be
installed with 48 100M SFP optical
modules.

03053420

CR5DL2XEFG70

NetEngine40E,CR57L2XEF
GB0,2-Port 10GBase
LAN/WAN-XFP+24-Port
100/1000Base-X-SFP
Integrated Line Processing
Unit (LPUI-41)

The line-rate forwarding capability is 50


Gbit/s;
The XFP optical module is required
additionally. At most two XFP optical
modules can be installed on each board.
The SFP optical module is required
additionally. At most 24 SFP optical
modules can be installed on each board.
SFP modules with 10M/100M/1000M
electrical interfaces can be installed on
the subcard.

03053542

CR5D0L4XXA70

NetEngine40E,CR57L4XXC
0,4-Port 10GBase
LAN/WAN-XFP Integrated
Line Processing Unit
(LPUI-41,Supporting
1588v2)

The line-rate forwarding capability is 50


Gbit/s;
The XFP optical module is required
additionally. At most four XFP optical
modules can be installed on each board.

03053543

CR5D0EKGFA70

03053544

CR5DL2XEEG7A

NetEngine40E,CR57EKGFC
0,40-Port
100/1000Base-X-SFP
Integrated Line Processing
Unit (LPUI-41,Supporting
1588v2)

The line-rate forwarding capability is 50


Gbit/s;The SFP optical module is required
additionally. At most 40 SFP optical
modules can be installed on each board.

NetEngine40E,CR57EKGFC
0,40-Port
100/1000Base-X-SFP
Integrated Line Processing
Unit (LPUI-41,Supporting
1588v2)

The line-rate forwarding capability is 50


Gbit/s;

SFP modules with 10M/100M/1000M


electrical interfaces can be installed on
the subcard.

The XFP optical module is required


additionally. At most two XFP optical
modules can be installed on each board.
The SFP optical module is required
additionally. At most 20 SFP optical
modules can be configured for each
board.
SFP modules with 10M/100M/1000M
electrical interfaces can be installed on
the subcard.

The LPUI-100 can only be used on the NE40E-X8/X16, and must be used with the 200G
MPU and 200G SFU. CR5D0SRUA570(03053549) and CR5DSFUIE07C (03053548) are
needed on NE40E-X8; CR5DSFUIE07B (03053547) is needed on the NE40E-X16.

3 Special Service Boards


NE40E provides multiple types of services boards.
BOM Number

SBOM Type

Description

Remarks

03030LXJ

CR53-SPU-C

NetEngine80E,CR53SPUCC0,Versatile The SPU does not provide


Service Process Unit C
interfaces to connect to external
interfaces. You can configure
different licenses for different
services.

03053128

CR5MVSUF1010 NetEngine80E, CR52VSUF10, Flexible The VSUF does not provide


Card Versatile Service Unit
interfaces to connect to external
10(VSUF-10)
interfaces. You can configure
different licenses for different
services. The flexible card is
supported in V600R002C02 and
later versions.

0305G062

CR5DVSUI201A (VSUI-20-A)

The board is supported since


V600R005C00.

4 Software, License
DescriptionStarting from V300R003, the NE40E/80E adopts the License-based sale
strategy. The general principle is as follows:
1. Base package
The base package is mandatory item to be purchased for the NE40E/80E of each version,
especially at a new site.

2. Feature license
Feature licenses are controlled and are sold according to the features required by
customers. Feature licenses of the NE40E/80E are classified into device licenses and
board licenses. For device licenses, each device needs to be configured with one device
license, for example, a 1588v2 Function License for the 1588v2 feature. For board
licenses, each board needs to be configured with one license, for example, the
LPUF-40-B Upgrade to LPUF-40-A License.
3. Upgrade fee
If customers attempt to upgrade the earlier versions to use new features, they need to pay
the upgrade fee. For upgrades on Huawei's account, such as bug fixing or contract
obligation, the upgrade fee is charged as required.
Software sale strategies may be adjusted. For detailed information about licenses on sale,
refer to the latest Quoter-d system.
BOM Number

SBOM Type

Description

Remarks

88030YTE

CR5S40BS6500

NetEngine40E&80E basic
software,VRP5, V600R005

Must be purchased for a


new site.

81400135

SWP-CR53LIC-V3R3Update

SWP-CR53LIC-V3R3Update NetEngine80E/40E
V300R003 upgrade

88030BUW

CR5S40EF0000

CR5S40EF0000

81400189

CR5S40CLCK00

NetEngine40E&80E 1588v2 It is a device license.


Function License

82400144

CR5S40BTOA00

NetEngine40E&80E
It is a board license.
LPUF-40-B Upgrade to
LPUF-40-A License (L3VPN,
Ability of MVPN, IPv6
Enhanced)

82400189

SWP-CR52LIC-21BToA

NetEngine80E/40E
LPUF-21/20-B Upgrade to
LPUF-21/20-A License
(IPv6, L3VPN, MVPN)

82400137

SWP-CR53LIC-NetStream-SPUC NetEngine80E/40E
NetStream License for
SPUC

Each SPUC requires one.

82400141

SWP-CR53LIC-MVPN-SPUC

NetEngine80E/40E MVPN
License for SPUC

Each SPUC requires one.

82400140

SWP-CR53LIC-Tunnel-SPUC

NetEngine80E/40E Tunnel
Each SPUC requires one.
(GRE, Lawful interception, 4
over 6, etc.) License for
SPUC

82400204

CR5S40VIDE00

Resource,
NetEngine40E&80E,
LCR5VIDE00,
NetEngine40E&80E Video
Enhanced Function License

Each VSUF-10 requires


one.

82400205

CR5S40SNAT00

NE40E&80E NAT License


for SPUC

Each SPUC requires one.

Software enhancement fee


for upgrading the
NE40E/80E from Rn to
R(n+1).

It is a board license.

81400208

CR5S40MHAG00

NE40E&80E Cross-chassis
HAG Function License

It is a device license.

82400207

CR5S40BRAS00

NE40E&80E PPPoE/IPoE
Function License for
LPUF-21

Each LPUF-21 requires one.

82400208

CR5S40BRAS01

NE40E&80E PPPoE/IPoE
Function License for
LPUF-40

Each LPUF-40 requires one.

81400210

CR5S40L2TP00

NetEngine40E&80E L2TP
Function License

It is a device license.

81400281

CR5S4000LI00

NetEngine40E&80E Lawful
Interception Function
License

It is a device license.

81400279

CR5S400DAA00

NetEngine40E&80E DAA
Function License

It is a device license.

81400285

CR5S400MDI00

NetEngine40E&80E Video
It is a device license.
Monitoring Function License

82400240

CR5S40NATS00

NetEngine40E&80E 2M
NAT Session License

It is a device license.

82400220

CR5S400DPI00

NetEngine40E&80E DPI
Function License for
VSUF-10

Each VSUF-10 requires one

82400247

CR5S40DUAF00

NetEngine40E&80E DPI
Signature Database
Upgrading Annual Fee

It is a device license.

5 Electrical or Optical Modules


NE40E provides multi electrical and optical Modules.
Bom

Description

Mode

Remarks

3406028
7

Optical
Transceiver,SFP,1310nm,STM1,-19~-14dBm,-30dBm,LC,MM,2km

Multimo
de

Recommended

3406027
6

Optical
Transceiver,eSFP,1310nm,STM1,-15~-8dBm,-31dBm,LC,SM,15km

Single
mode

Recommended

3406028
1

Optical
Transceiver,eSFP,1310nm,STM1,-5~0dBm,-37dBm,LC,SM,40km

Single
mode

Recommended

3406028
2

Optical
Transceiver,eSFP,1550nm,STM1,-5~0dBm,-37dBm,LC,SM,80km

Single
mode

Recommended

3406028
7

Optical
Transceiver,SFP,1310nm,STM1,-19~-14dBm,-30dBm,LC,MM,2km

Multimo
de

Recommended

3406029
9

Optical
Transceiver,eSFP,1310nm,STM1,-15~-8dBm,-31dBm,LC,SM,15km

Single
mode

Recommended

3406030
0

Optical
Transceiver,eSFP,1310nm,STM1,-5~0dBm,-37dBm,LC,SM,40km

Single
mode

Recommended

3406030
1

Optical
Transceiver,eSFP,1550nm,STM1,-5~0dBm,-37dBm,LC,SM,80km

Single
mode

Recommended

3406055
5

BiDi Transceiver,CSFP,1550(Tx) /
1310(Rx)nm,125~155Mbps,-14dBm,-8dBm,-28.2dBm,LC,SM,10km

Single
mode

Recommended

3406030
2

Optical
Transceiver,eSFP,1310nm,STM4,-15~-8dBm,-31dBm,LC,SM,15km

Single
mode

Recommended

3406030
3

Optical
Transceiver,eSFP,1310nm,STM4,-3~2dBm,-30dBm,LC,SM,40km

Single
mode

Recommended

3406030
4

Optical
Transceiver,eSFP,1550nm,STM4,-3~2dBm,-30dBm,LC,SM,80km

Single
mode

Recommended

3406028
6

Optical Transceiver,eSFP,850nm,2.125Gb/s(Multi
rate) ,-9.5~-2.5dBm,-17dBm,LC,MM,0.5km

Multi-m
ode

Recommended

3406021
9

Optical
transceiver,eSFP,1310nm,1.25Gb/s,-9.5~-3dBm,-20dBm,LC,SM,10k
m

Single
mode

Sales restricted

3406029
8

Optical
Transceiver,eSFP,1310nm,1.25Gb/s,-5~0dBm,-23dBm,LC,SM,40km

Single
mode

Recommended

3406006
9

Optical
Transceiver,SFP,1550nm,1.25Gb/s,1dBm,-4dBm,-21dBm,LC(-40~85)
,40km

Single
mode

Recommended

3406027
4

Optical
Transceiver,eSFP,1550nm,1.25Gb/s,-2~5dBm,-23dBm,LC,SM,80km

Single
mode

Sales restricted

3406029
5

Optical
Transceiver,eSFP,1550nm,1.25Gb/s,0~5dBm,-30dBm,LC,SM,100km

Single
mode

Recommended

3410008
0

Optical Function Module,1000BASE-T,RJ45 Electrical Interface SFP


Module, Auto Negotiate, Maximum Transmission Distance 100m

3406047
3

Optical
transceiver,eSFP,1310nm,1.25Gb/s,-9~-3dBm,-20dBm,LC,Single
Mode,10km

Single
mode

Recommended

3406036
0

Optical
Transceiver,eSFP,1550nm,1.25Gb/s,-2~5dBm,-23dBm,LC,SM,80km

Single
mode

Recommended

3406035
1

Optical
transceiver,eSFP,1471nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k
m

Single
mode

3406035
0

Optical
transceiver,eSFP,1491nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k
m

Single
mode

3406031
5

Optical
transceiver,eSFP,1511nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k
m

Single
mode

3406033
2

Optical
transceiver,eSFP,1531nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k
m

Single
mode

3406034
6

Optical
transceiver,eSFP,1551nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k
m

Single
mode

3406034
7

Optical
transceiver,eSFP,1571nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k
m

Single
mode

3406034
8

Optical
transceiver,eSFP,1591nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k
m

Single
mode

Recommended

3406034
9

Optical
transceiver,eSFP,1611nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k
m

Single
mode

3410008
0

Optical Function Module,1000BASE-T,RJ45 Electrical Interface SFP


Module, Auto Negotiate, Maximum Transmission Distance 100m

RJ45

Recommended

3406047
0

Optical
Transceiver,ESFP,Tx1310/Rx1490,1.25Gb/s,-3dBm,-9dBm,-19.5dBm
,LC,Single Mode,10km

Single
mode

It must be used
with the optical
module with the
BOM number
being
34060475.

3406047
5

Optical
Transceiver,ESFP,Tx1490/Rx1310,1.25Gb/s,-3dBm,-9dBm,-19.5dBm
,LC,Single Mode,10km

Single
mode

It must be used
with the optical
module with the
BOM number
being
34060470.

3406052
5

Integrated Optical Transmitting and Receiving


Module,CSFP,Transmitting:1490nm,Receiving:1310nm,1.25Gb/s,-9.0
dBm,-3.0dBm,-19.5dBm,LC,10km

Single
mode

It must be used
with the optical
module with the
BOM number
34060470.

3406028
8

Optical
Transceiver,eSFP,1310nm,STM16,-10~-3dBm,-21dBm,LC,SM,2km

Single
mode

Recommended

3406027
8

Optical
Transceiver,eSFP,1310nm,STM16,-5~0dBm,-21dBm,LC,SM,15km

Single
mode

Recommended

3406028
9

Optical
Transceiver,eSFP,1310nm,STM16,-2~3dBm,-29dBm,LC,SM,40km

Single
mode

Recommended

3406027
9

Optical
Transceiver,eSFP,1550nm,STM16,-2~3dBm,-30dBm,LC,SM,80km

Single
mode

Sales restricted.

3406048
8

Optical
Transceiver,eSFP,1550nm,STM16,-2~3dBm,-30dBm,LC,SM,80km

Single
mode

Recommended

3406036
2

Optical
Transceiver,XFP,850nm,10.3Gb/s,-7.3dBm,-1.3dBm,-7.5dBm,LC,MM,
0.3km

Multimo
de

Applied to the
10 GBase LAN
only

3406031
3

Optical
Transceiver,XFP,1310nm,9.95~10.71Gb/s,-6dBm~-1dBm,-14.4dBm,L
C,SM,10km

Single
mode

Applied to the
10 G POS, 10
GBase LAN,
and 10 GBase
WAN

3406032
2

Optical Transceiver,XFP,1550nm,9.95Gb/s to
11.1Gb/s,+2dBm,-1dBm,-15dBm,LC,Single-mode,40km

Single
mode

Applied to the
10 G POS, 10
GBase LAN,
and 10 GBase
WAN

3406036
1

Optical transceiver,XFP,1550nm,9.95Gb/s to
11.1Gb/s,0~4dBm,-24dBm,LC,Single-mode,80km

Single
mode

Applied to the
10 G POS, 10
GBase LAN,
and 10 GBase
WAN

3406049
4

XFP|SFP+ Optical
transceiver,SFP+,850nm,10Gb/s,-7.3~-1dBm,-11.1dBm,LC,
MM,0.3km

Multi-m
ode

Can only be
used in the
10GBase LAN.

3406049

XFP|SFP+ Optical

Single

Can only be

transceiver,SFP+,1310nm,10Gb/s,-8.2~0.5dBm,-12.6dBm,LC,SM,10k
m

mode

used in the
10GBase LAN.

3406051
8

XFP|SFP+ Optical
transceiver,SFP+,1550nm,9.95~11.1Gb/s,-4.7~4dBm,-14.1dBm,LC,S
M,40km

Single
mode

Can be used in
the 10G POS,
10GBase LAN,
and 10GBase
WAN..

3406057
0

High Speed Transceiver,CFP-1295nm 1300nm 1304nm


1309nm-103.125Gbps--4.3dBm-4.5dBm--8.6dBm-SC-SMF-10km

singlemode

Can only be
used in
10GBase-CFP
interfaces..

6 Combinet
Combinet An assembly cabinet is optional. According to customers'

requirements, an NE40E/80E can be installed in an assembly cabinet or in the


cabinet provided by the customer, or directly used without being installed in a
cabinet.
BOM
02113041

SBOM Type
CR52-22-D

Description
NE80E,CR5B2N68E,2.
2m Router Assembly
Cabinet with Double
Swing Doors,N68E-22

Remarks
Applicable for NE40E-X3,
NE40E-X16, and NE40E-X8

7 External Cable Suites


1

Configuration Notes of Power Cables


Configuration notes of external cables and terminals of the NEPS3000-D
Length in Site
Survey

Configurations of External Cables and Terminals


BOM Number

Equal to or shorter
than 25 m

Description

Configuration Notes

25030101

Wire,450/750V,227 IEC
02(RV)25mm^2,Blue,110A

Each power module is equipped


with one cable of this type. The
cable length is determined by the
site survey result.

25030432

Wire,450/750V,227 IEC
02(RV),25mm^2,Black,110A

Each power module is equipped


with one cable of this type. The
cable length is determined by the
site survey result.

14170121

Naked Crimping
Each cable is equipped with one
connector,JG2,25mm^2,M8,150A,Si terminal of this type, which is
lver Plated
used to connect to the power
module.

14170060

Naked Crimping
Terminal,OT,25mm^2,M8,Tin

Each cable is equipped with one


terminal of this type, which is

Length in Site
Survey

Configurations of External Cables and Terminals


BOM Number

Longer than 25 m
and equal to or
shorter than 35 m

Longer than 35 m

Description

Configuration Notes

Plating,Naked Ring Terminal

used to connect to the power


distribution frame.

25030199

Wire,450/750V,227 IEC
02(RV),35mm^2,Blue,135A

Each power module is equipped


with one cable of this type. The
cable length is determined by the
site survey result.

25030420

Wire,450/750V,227 IEC
02(RV),35mm^2,Black,135A

Each power module is equipped


with one cable of this type. The
cable length is determined by the
site survey result.

14170128

Naked Crimping
Each cable is equipped with one
Connector,JG2,35mm^2,M8,210A,T terminal of this type, which is
in Plating,For OEM
used to connect to the power
module.

14170063

Naked Crimping
Terminal,OT,35mm^2,M8,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one


terminal of this type, which is
used to connect to the power
distribution frame.

A power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables and terminals of the NEPS5000-D


Length in the Site
Survey

Configurations of External Cables and Terminals


BOM Number

Equal to or shorter
than 25 m

Longer than 25 m
and shorter than 35
m

Description

Configuration Notes

25030430

Wire,450/750V,227 IEC
02(RV),16mm^2,Blue,85A

Each power module is equipped with three


cables of this type. The cable length is
determined by the site survey result.

25030428

Wire,450/750V,227 IEC
02(RV),16mm^2,Black,85A

Each power module is equipped with three


cables of this type. The cable length is
determined by the site survey result.

14170020

Naked Crimping
Terminal,OT,16mm^2,M6,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one terminal of


this type, which is used to connect to the
power module.

14170024

Naked Crimping
Terminal,OT,16mm^2,M8,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one terminal of


this type, which is used to connect to the
power distribution frame.

25030101

Wire,450/750V,227 IEC
02(RV),25mm^2,Blue,110A

Each power module is equipped with three


cables of this type. The cable length is
determined by the site survey result.

25030432

Wire,450/750V,227 IEC
02(RV),25mm^2,Black,110A

Each power module is equipped with three


cables of this type. The cable length is
determined by the site survey result.

14170147

Naked Crimping
Terminal,OT,25mm^2,M6,Tin
Plating,Width Less Than
12.4mm,For OEM

Each cable is equipped with one terminal of


this type, which is used to connect to the
power module.

14170060

Naked Crimping
Terminal,OT,25mm^2,M8,Tin

Each cable is equipped with one terminal of


this type, which is used to connect to the

Plating,Naked Ring Terminal


Longer than 35 m

power distribution frame.

A power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables and terminals of the NEPS8000-D


Length in the Site
Survey

Configurations of External Cables and Terminals


BOM Number

Equal to or shorter
than 25 m

Longer than 25 m
and shorter than 35
m

Longer than 35 m

Description

Configuration Notes

25030430

Wire,450/750V,227 IEC
02(RV),16mm^2,Blue,85A

Each power module is equipped with three


cables of this type. The cable length is
determined by the site survey result.

25030428

Wire,450/750V,227 IEC
02(RV),16mm^2,Black,85A

Each power module is equipped with three


cables of this type. The cable length is
determined by the site survey result.

14170020

Naked Crimping
Terminal,OT,16mm^2,M6,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one terminal of


this type, which is used to connect to the
power module.

14170024

Naked Crimping
Terminal,OT,16mm^2,M8,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one terminal of


this type, which is used to connect to the
power distribution frame.

25030101

Wire,450/750V,227 IEC
02(RV),25mm^2,Blue,110A

Each power module is equipped with three


cables of this type. The cable length is
determined by the site survey result.

25030432

Wire,450/750V,227 IEC
02(RV),25mm^2,Black,110A

Each power module is equipped with three


cables of this type. The cable length is
determined by the site survey result.

14170147

Naked Crimping
Terminal,OT,25mm^2,M6,Tin
Plating,Width Less Than
12.4mm,For OEM

Each cable is equipped with one terminal of


this type, which is used to connect to the
power module.

14170060

Naked Crimping
Terminal,OT,25mm^2,M8,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one terminal of


this type, which is used to connect to the
power distribution frame.

A power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables and terminals of the AC power


NEPS3000-A
BOM Number

Description

Configuration Notes

25030422

Power
Cable,300/500V,227IEC10(BVV),Black(Cores:
Blue,Brown,Yellow/Green),36A,3*6mm^2

Each power module is equipped with one


cable of this type. The cable length is
determined by the site survey result.

14170013

Naked Crimping Terminal,OT,6mm^2,M8,Tin


Plating,Insulated Ring
Terminal,12~10AWG,yellow

Each cable is equipped with three terminals


of this type, which are used to connect to
the power distribution frame.

14170017

Naked Crimping Terminal,OT,6mm^2,M4,Tin


Plating,Insulated Ring
Terminal,12~10AWG,yellow

Each cable is equipped with three terminals


of this type, which are used to connect to
the power module.

Configuration notes of external cables and terminals of the AC power


NEPS5000-A
BOM Number

Description

Configuration Notes

25030463

Power
Cable,300/500V,227IEC10(BVV),10mm^2,Black
Jacket(Cores:
Blue,Brown,Black,Yellow/Green),46A,4 Equivalent
Cores

Each power module is equipped with


one cable of this type, which is used to
connect the AC power distribution
frame and power distribution box.

04043396

Chinese AC Power Cable


220V16A,3m,3*2.5mm^2,Black,I-Type Angle
Plug,227IEC53-2.5^2(3C),C19 Straight Connector

Each power module is equipped with


three cables of this type, which are
used to connect the power distribution
box and the input terminal of the AC
power module.

02120415

NetEngine5000E,CR5E3TSR,AC Distribution Frame


for Cabinet,2 or 6 Input,6(2*3) Output,6 Group of 2
Poles 20A Air Switch

Each device is equipped with 1 pcs.


The price of this item needs to be
separately quoted.

14170146

Common Terminal,Single Cord End


Terminal,Conductor Cross Section
10mm^2,50A,Insertion Depth 18mm,Ivory

Each cable (25030463) is equipped


with three terminals of this type, which
are used to connect the input terminal
of the power distribution box.

14170016

Naked Crimping Terminal,OT,10mm^2,M6,Tin


Plating,Naked Ring Terminal

Each cable (25030463) is equipped


with three terminals of this type, which
are used to connect the AC power
distribution frame.

14170098

Common Terminal,Single Cord End


Terminal,Conductor Cross Section
2.5mm^2,12.5A,Insertion Depth 8mm,Blue

Each cable (04043396) is equipped


with three terminals of this type, which
are used to connect the output terminal
of the power distribution box.

Configuration notes of external cables and terminals of the NE40E-X3 DC chassis


Length in the Site
Survey

Configurations of External Cables and Terminals


BOM Number

Equal to or shorter
than 15 m

Description

Configuration Notes

25030430

Wire,450/750V,227 IEC
02(RV),16mm^2,Blue,85A

Each DC chassis is equipped with two


cables of this type. The cable length is
determined by the site survey result.

25030428

Wire,450/750V,227 IEC
02(RV),16mm^2,Black,85A

Each DC chassis is equipped with two


cables of this type. The cable length is
determined by the site survey result.

14170116

Naked Crimping
Each cable is equipped with one
Connector,JG2,16mm^2,M6,95A,T terminal of this type, which is used to
in Plated,for OEM
connect to the PEM.

14170024

Naked Crimping
Terminal,OT,16mm^2,M8,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one


terminal of this type, which is used to
connect to the power distribution frame.

Wire,450/750V,227 IEC
02(RV),25mm^2,Blue,110A

Each DC chassis is equipped with two


cables of this type. The cable length is
determined by the site survey result.

Longer than 15 m
25030101
and shorter than 35
m

Length in the Site


Survey

Configurations of External Cables and Terminals


BOM Number

Longer than 35 m

Description

Configuration Notes

25030432

Wire,450/750V,227 IEC
02(RV),25mm^2,Black,110A

Each DC chassis is equipped with two


cables of this type. The cable length is
determined by the site survey result.

14170119

Naked Crimping
Each cable is equipped with one
Connector,JG2,25mm^2,M6,150A, terminal of this type, which is used to
Tin Plating,For OEM
connect to the PEM.

14170060

Naked Crimping
Terminal,OT,25mm^2,M8,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one


terminal of this type, which is used to
connect to the power distribution frame.

A power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables of the NE40E-X3 AC chassis


BOM Number
04000104

Description
External Suite, Power Cords All Over The World, Class I
Equipment With Connector C13,External Cable Set

Configuration Notes
Different cables are used in
different countries. Each AC
chassis is equipped with 2 pcs.

Rules for selecting the AC power cable for the NE40E-X3 are as follows:
1. AC power cables are selected according to local cable standards in the country
where the device is deployed.
2. The required length of the power cables is determined based on the length in the
site survey.
3. The following formulas are used to calculate the number of required power
cables:
Number of power cables of each type = 2 pcs x Number of devices
In the 100V/110V/120V AC power supply system, input of double live wires is
required. In this case, the input voltage ranges from 176 VAC to 275 VAC, and any two
phases can be input to the AC power module. In the external cable suite (04000104), the
C13-end of the three-core power cable has three terminals marked L, N, and PE. L
stands for live wire 1; N stands for live wire 1; PE stands for the ground wire. The other
end of the three-core power cable must be cut off for cable making. The terminal is
specified in the site survey.
In the 100V/110V/120V AC power supply system, if input of double live wires cannot be
provided, the NE40E-X3 AC chassis is not recommended.

Configuration notes of external cables and terminals of the NE40E-X8 DC chassis

Length in the Site


Survey

Configurations of External Cables and Terminals


BOM Number

Equal to or shorter
than 15 m

Longer than 15 m
and shorter than 25
m

Longer than 25 m
and shorter than 35
m

Longer than 35 m

Description

Configuration Notes

25030430

Wire,450/750V,227 IEC
02(RV),16mm^2,Blue,85A

Each DC chassis is equipped with


four cables of this type. The cable
length is determined by the site
survey result.

25030428

Wire,450/750V,227 IEC
02(RV),16mm^2,Black,85A

Each DC chassis is equipped with


four cables of this type. The cable
length is determined by the site
survey result.

14170024

Naked Crimping
Terminal,OT,16mm^2,M8,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one


terminal of this type, which is used
to connect to the power distribution
frame.

14170116

Naked Crimping
Connector,JG2,16mm^2,M6,95A,Tin
Plated,for OEM

Each cable is equipped with one


terminal of this type, which is used
to connect to the PEM.

25030101

Wire,450/750V,227 IEC
02(RV),25mm^2,Blue,110A

Each DC chassis is equipped with


four cables of this type. The cable
length is determined by the site
survey result.

25030432

Wire,450/750V,227 IEC
02(RV),25mm^2,Black,110A

Each DC chassis is equipped with


four cables of this type. The cable
length is determined by the site
survey result.

14170060

Naked Crimping
Terminal,OT,25mm^2,M8,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one


terminal of this type, which is used
to connect to the power distribution
frame.

14170119

Naked Crimping
Connector,JG2,25mm^2,M6,150A,Tin
Plating,For OEM

Each cable is equipped with one


terminal of this type, which is used
to connect to the PEM.

25030199

Wire,450/750V,227 IEC
02(RV),35mm^2,Blue,110A

Each DC chassis is equipped with


four cables of this type. The cable
length is determined by the site
survey result.

25030420

Wire,450/750V,227 IEC
02(RV),35mm^2,Black,110A

Each DC chassis is equipped with


four cables of this type. The cable
length is determined by the site
survey result.

14170159

Naked Crimping
Each cable is equipped with one
Connector,JG2,34.3mm^2,M6(1/4"),13 terminal of this type, which is used
4A,Tin Plated,2AWG,Hole Center
to connect to the PEM.
Distance 15.875mm(5/8"),Short
Tube,for North American

14170063

Naked Crimping
Terminal,OT,35mm^2,M8,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one


terminal of this type, which is used
to connect to the power distribution
frame.

A power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables and terminals of the NE40E-X8 in AC

power supply mode


Length in the Site
Survey

Configurations of External Cables and Terminals


BOM Number

The distance between


the NE40E-X8 chassis
and the AC-DC
converter is equal to or
shorter than 3 m.

The distance between


the AC-DC converter
and the AC power
distribution frame is
longer than 50 m.

Configuration Notes

25030430

Wire,450/750V,227 IEC
02(RV),16mm^2,Blue,85A

Each DC chassis is equipped with four


cables of this type. The cable length is
determined by the site survey result.

25030428

Wire,450/750V,227 IEC
02(RV),16mm^2,Black,85A

Each DC chassis is equipped with four


cables of this type. The cable length is
determined by the site survey result.

14170116

Naked Crimping
Each cable is equipped with two
Terminal,JG2,16mm^2,M6,95A, terminals of this type, which are used to
Tin Plated,for OEM
connect the PEM and AC-DC converter.

04080076

Monitor and Alarm


Each NE40E-X8 that adopts the AC
Cable,3m,D9M,CC4P0.48B(S), power supply mode is equipped with
D9M
one monitor and alarm cable, which is
used to connect the AC-DC converter
and the NE40E-X8 DC chassis.

The distance between


(1)
the NE40E-X8 chassis
(2)
and the AC-DC
converter is longer than
3 m.
The distance between
the AC-DC converter
and the AC power
distribution frame is
equal to or shorter than
50 m.

Description

It is recommended to deploy the AC-DC converter near the DC chassis.


If it is difficult to deploy the AC-DC converter near the DC chassis, see the deployment of
the AC power cable in the DC power supply system. In this case, the DC chassis cannot
manage the AC-DC converter.

25030461

Power
Each AC chassis is equipped with
Cable,300/500V,227IEC10(BVV),6 four cables of this type.
mm^2,Black
Jacket(Cores:Blue,Brown),43A,2
Equivalent Cores

14170023

Naked Crimping
Terminal,OT,6mm^2,M6,Tin
Plating,Insulated Ring
Terminal,12~10AWG,yellow

Each AC power cable is equipped


with two terminals of this type on the
two cores, which are used to connect
to the binding post of the AC-DC
converter.

14170013

Naked Crimping
Terminal,OT,6mm^2,M8,Tin
Plating,Insulated Ring
Terminal,12~10AWG,yellow

Each AC power cable is equipped


with two terminals of this type on the
two cores, which are used to connect
to the binding post of the AC power
distribution frame.

An AC power distribution frame or the first power cabinet of a row should be placed near the
device.

Configuration notes of external cables and terminals of the NE40E-X16 DC


chassis

Length in the Site


Survey

Configurations of External Cables and Terminals


BOM Number

Equal to or shorter
than 15 m

Configuration Notes

25030430

Wire,450/750V,227 IEC
02(RV),16mm^2,Blue,85A

Each DC chassis is equipped with eight


cables of this type. The cable length is
determined by the site survey result.

25030428

Wire,450/750V,227 IEC
02(RV),16mm^2,Black,85A

Each DC chassis is equipped with eight


cables of this type. The cable length is
determined by the site survey result.

14170024

Naked Crimping
Terminal,OT,16mm^2,M8,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one terminal


of this type, which is used to connect to
the power distribution frame.

14170116

Naked Crimping
Each cable is equipped with one terminal
Terminal,JG2,16mm^2,M6,95A,T of this type, which is used to connect to
in Plated,for OEM
the PEM.

Longer than 15 m
25030101
and shorter than 35
m

Wire,450/750V,227 IEC
02(RV),25mm^2,Blue,110A

Each DC chassis is equipped with eight


cables of this type. The cable length is
determined by the site survey result.

25030432

Wire,450/750V,227 IEC
02(RV),25mm^2,Black,110A

Each DC chassis is equipped with eight


cables of this type. The cable length is
determined by the site survey result.

14170060

Naked Crimping
Terminal,OT,25mm^2,M8,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one terminal


of this type, which is used to connect to
the power distribution frame.

14170119

Naked Crimping
Connector,JG2,25mm^2,M6,150
A,Tin Plating,For OEM

Each cable is equipped with one terminal


of this type, which is used to connect to
the PEM.

Wire,450/750V,227 IEC
02(RV),35mm^2,Blue,135A

Each DC chassis is equipped with eight


cables of this type. The cable length is
determined by the site survey result.

25030420

Wire,450/750V,227 IEC
02(RV),35mm^2,Black,135A

Each DC chassis is equipped with eight


cables of this type. The cable length is
determined by the site survey result.

14170159

Naked Crimping
Connector,JG2,34.3mm^2,M6(1/
4"),134A,Tin Plated,2AWG,Hole
Center Distance
15.875mm(5/8"),Short Tube,for
North American

Each cable is equipped with one terminal


of this type, which is used to connect to
the PEM.

14170063

Naked Crimping
Terminal,OT,35mm^2,M8,Tin
Plating,Naked Ring Terminal

Each cable is equipped with one terminal


of this type, which is used to connect to
the power distribution frame.

Longer than 25 m
25030199
and shorter than 35
m

Longer than 35 m

Description

A power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables and terminals of the NE40E-X16 in AC


power supply mode
Length in the Site Survey

Configurations of External Cables and Terminals


BOM Number

The distance between the 25030430

Description
Wire,450/750V,227 IEC

Configuration Notes
Each DC chassis is equipped with

Length in the Site Survey

Configurations of External Cables and Terminals


BOM Number

Description

NE40E-X16 chassis and


the AC-DC converter is
equal to or shorter than 3
m.

Configuration Notes

02(RV),16mm^2,Blue,85A

eight cables of this type. The cable


length is determined by the site
survey result.

25030428

Wire,450/750V,227 IEC
02(RV),16mm^2,Black,85A

Each DC chassis is equipped with


eight cables of this type. The cable
length is determined by the site
survey result.

14170116

Naked Crimping
Each cable is equipped with two
Terminal,JG2,16mm^2,M6,95A, terminals of this type, which are used
Tin Plated,for OEM
to connect the PEM and AC-DC
converter.

04080076

Monitor and Alarm


Cable,3m,D9M,CC4P0.48B(S),
D9M

Each NE40E-X16 that adopts the AC


power supply mode is equipped with
two monitor and alarm cables, which
are used to connect the AC-DC
converter and the NE40E-X16 DC
chassis.

The distance between the


(1) It is recommended to deploy the AC-DC converter near the DC chassis.
NE40E-X16 chassis and
the AC-DC converter is
(2) If it is difficult to deploy the AC-DC converter near the DC chassis, see the deployment
longer than 3 m.
of the AC power cable in the DC power supply system. In this case, the DC chassis
cannot manage the AC-DC converter.
The distance between the 25030461
AC-DC converter and the
AC power distribution
frame is equal to or
shorter than 50 m.

Power
Cable,300/500V,227IEC10(BVV),6
mm^2,Black
Jacket(Cores:Blue,Brown),43A,2
Equivalent Cores

Each AC chassis is configured with


four cables of this type.

14170023

Naked Crimping
Terminal,OT,6mm^2,M6,Tin
Plating,Insulated Ring
Terminal,12~10AWG,yellow

Each AC power cable is equipped


with two terminals of this type on the
two cores, which are used to connect
to the binding post of the AC-DC
converter.

14170013

Naked Crimping
Terminal,OT,6mm^2,M8,Tin
Plating,Insulated Ring
Terminal,12~10AWG,yellow

Each AC power cable is equipped


with two terminals of this type on the
two cores, which are used to connect
to the binding post of the AC power
distribution frame.

The distance between the An AC power distribution frame or the first power cabinet of a row should be placed near the
AC-DC converter and the device.
AC power distribution
frame is longer than 50
m.

Configuration Notes of Ground Cables


Configuration notes of the ground cable and terminals used on the NE40E-X3

BOM Number
25030431

Description
Wire,450/750V,60227 IEC
02(RV)25mm^2,yellow green,110A

Configuration Notes
Each device is equipped with one such power cable. The
length of the power cable is based on the site survey
result. If the device is grounded through a cabinet, the

BOM Number

Description

Configuration Notes
length of the ground cable is a1 shown in
; if the device is grounded through a chassis, the
length of the ground cable is a3 shown in
.

14170119

Naked Crimping
Connector,JG2,25mm^2,M6,150A,Tin
Plating,For OEM

One such terminal is used to connect to the ground


terminal on the chassis.

14170060

Naked Crimping
Terminal,OT,25mm^2,M8,Tin
Plating,Naked Ring Terminal

When a device is grounded through a chassis, one such


terminal is used to connect to the ground bar in the
equipment room.
If a device is grounded through a cabinet, one such
terminal is used to connect to the ground point on the
cabinet.

Configuration notes of the ground cable and terminals used on the


NE40E-X8/NE40E-X16
BOM Number

Description

Configuration Notes

25030431

Wire,450/750V,60227 IEC
02(RV)25mm^2,yellow green,110A

Each device is equipped with one such power


cable. The length of the power cable is based on
the site survey result. If the device is grounded
through a cabinet, the length of the ground cable is
a1 shown in ; if the device is
grounded through a chassis, the length of the
ground cable is a3 shown in .

14170119

Naked Crimping
Connector,JG2,25mm^2,M6,150A,Tin
Plating,For OEM

One such terminal is used to connect to the ground


terminal on the chassis.

14170060

Naked Crimping
Terminal,OT,25mm^2,M8,Tin
Plating,Naked Ring Terminal

When a device is grounded through a chassis, one


such terminal is used to connect to the ground bar
in the equipment room.
If a device is grounded through a cabinet, one
such terminal is used to connect to the ground
point on the cabinet.

Configuration Notes of Ground Cable of the EPS200-4850A


The external AC-DC converter EPS200-4850A of the NE40E-X8/NE40E-X16 needs to be
separately grounded. Therefore, the 25 mm^2 ground cable is needed. The below lists the
configuration notes of the ground cable and terminals used on the EPS200-4850A.
Configuration notes of the ground cable and terminals used on the
EPS200-4850A
BOM Number
25030431

Description
Wire,450/750V,60227 IEC
02(RV)25mm^2,yellow green,110A

Configuration Notes
Each device is equipped with one such power cable.
The length of the power cable is based on the site
survey result. If the device is grounded through a
cabinet, the length of the ground cable is a1 shown in

; if the device is grounded


through a chassis, the length of the ground cable is
a3 shown in .
14170119

Naked Crimping
One such terminal is used to connect to the ground
Connector,JG2,25mm^2,M6,150A,Tin terminal on the chassis.
Plating,For OEM

14170060

Naked Crimping
Terminal,OT,25mm^2,M8,Tin
Plating,Naked Ring Terminal

When a device is grounded through a chassis, one


such terminal is used to connect to the ground bar in
the equipment room.
If a device is grounded through a cabinet, one such
terminal is used to connect to the ground point on the
cabinet.

Configuration Notes of Clock Cables


List of clock cables that can be used in NE40E&80E V600R005C00

No.
1

BOM Number
04022629

Description

Length

Trunk
20 m
Cable,20.00m,75ohm,2.2mm,SMB
75SF-V,SYFVZ75-1.2/0.25,HONE
T,DL2526

Cable Type
Cable with one
SMB connector
which is used to
connect to the
MPU/SRU. The
connector on the
other end of the
cable must be
provided by the
customer.

04060205

Trunk
30 m
Cable,30.00m,75ohm,2.2mm,SMB
75SF-V,SYFVZ75-1.2/0.25,Wirele
ss Intelligent Network

04023971

Trunk
40 m
Cable,40.00m,75ohm,2.2mm,SMB
75SF-V,SYFVZ75-1.2/0.25,C&C0
8B,DL3133

04023972

Trunk
50 m
Cable,50.00m,75ohm,2.2mm,SMB
75SF-V,SYFVZ75-1.2/0.25,C&C0
8B,DL3134

04060171

Trunk Cable,155M
5m
Self-Loop,5m,75ohm,4.0mm,SMB
75SF-IV,SYV75-2/0.34(S),SMB75
SF-IV,OptiX

Cable with two


SMB connectors

04040497

Trunk
3m
Cable,3m,120ohm,1E1,0.4mm,MP
8-II,120CC4P0.4P430U(S),MP8-II,
Expert 2.0

Cable with RJ48


connectors

04040261

Trunk
15 m
Cable,15m,120ohm,1E1,0.4mm,M
P8-II,120CC4P0.4P430U(S),MP8II

04040496

Trunk
30 m
Cable,30m,120ohm,1E1,0.4mm,M
P8-II,120CC4P0.4P430U(S),MP8II,Expert 2.0

04040494

Trunk
Cable,60.00m,120ohm,1E1,0.4m
m,MP8-II,120CC4P0.4P430U(S),

60 m

Configuration Notes
These cables are not
supported on the
CR52MPUD.
Each
CR52MPUA0/CR52SR
UA0/CR52MPUB0/CR
52SRUA1 can have 0
to 4 pcs.
Each
CR52MPUB2/CR52SR
UA3/CR56MPUB4/CR
57SRU40A4 can have
0 to 2 pcs.

Each
CR52MPUD/CR52MP
UB2/CR52SRUA3/CR5
6MPUB4/CR57SRU40
A4 can have 0 to 2 pcs.
These cables are not
supported on the
CR52MPUA0/CR52SR
UA0/CR52MPUB0/CR
52SRUA1.

No.

BOM Number

Description

Length

Cable Type

Configuration Notes

MP8-II,Expert 2.0
10

04040493

Trunk
80 m
Cable,80m,120ohm,1E1,0.4mm,M
P8-II,120CC4P0.4P430U(S),MP8II,Expert 2.0

11

14080082

Network Interface Connector,8Bit


8Pin,Crystal Plug,Matching
25050014

2 pcs

Cable with RJ45


connectors

12

25050014

Twisted-Pair
Cable,100ohm,Category 5e
UTP,0.51mm,24AWG,8Cores,PA
NTONE 430U,Use with
Plug:14080082

Based on
the site
survey
result

Balanced cable

These cables are


optional when the clock
interfaces on the
CR52MPUD/CR52MP
UB2/CR52SRUA3/CR5
6MPUB4/CR57SRU40
A4 support 1PPS+TOD
or DCLS.

Configuration Notes of E1/T1 Interface Cables


Configurations of the conversion box and cables for the CR5M1CFE1

BOM Number

Description

Configuration Notes

02351606

NetEngine80E,CR5Z1DCRF,24*E1/T1 The conversion box of this type corresponds to one


DB100 to RJ48 Port Conversion Box
CR5M1CFE1 LPU. The LPU and the conversion box are
connected through the 04070064 cable. The conversion
box is separately packaged.

02351607

NetEngine80E,CR5Z1DCRM,48*E1/T1 The conversion box of this type corresponds to two


DB100 to RJ48 Port Conversion Box
CR5M1CFE1 LPUs. The LPU and the conversion box are
connected through two sets of 04070064 cables. The
conversion box is separately packaged.

02351608

NetEngine80E,CR5Z1DCSF,24*E1
DB100 to SMB Port Conversion Box

04070064

Signal cable,24E1 Transit


It is used to connect the E1 conversion box and E1 LPU.
Cable,4m,D100M-I,3*CC16P0.4P430U Each LPU is equipped with one cable of this type.
(S)-I,D100M-I

The conversion box of this type corresponds to one


CR5M1CFE1 LPU. The LPU and the conversion box are
connected through the 04070064 cable. The conversion
box is separately packaged.

If coaxial cables with SMB connectors are used, the conversion box
02351608 must be selected. If twisted pair cables with RJ48 connectors are used,
the conversion box 02351606 or 02351607 must be selected. When the interface
on the CFE1 board needs to be connected to the E1 interface on another device,
you need to take the matching between cable impedances into consideration
when selecting a cable.
1.

The peer interface (RJ48) uses the 120-ohm balanced cable.

When the remote interface uses the balanced 120-ohm twisted cable and
RJ48 connector, select the E1 trunk cable from Table 8-26 based on the site
survey length. The listed cables are with RJ48 connectors at both ends.
E1 trunk cable list (RJ48 interface)

No.

BOM Number

Description

Quantity

Unit

04040497

Trunk
One for each E1
Cable,3m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P4 interface
30U(S),MP8-II,Expert 2.0

pcs

04040261

Trunk
One for each E1
Cable,15m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P interface
430U(S),MP8-II

pcs

04040496

Trunk
One for each E1
Cable,30m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P interface
430U(S),MP8-II,Expert 2.0

pcs

04040494

Trunk
One for each E1
Cable,60.00m,120ohm,1E1,0.4mm,MP8-II,120CC4P0. interface
4P430U(S),MP8-II,Expert 2.0

pcs

04040493

Trunk
One for each E1
Cable,80m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P interface
430U(S),MP8-II,Expert 2.0

pcs

2. The peer interface (SMB) uses the 75-ohm unbalanced cable.


When the remote interface uses the SMB connector, the conversion box 02351608 should
be selected for the CFE1 LPU, providing 24 SMB interfaces. Select corresponding cables
from Table 8-28 based on the site survey length.
In addition, the SMB trunk cable has one connector on one end, used to connect to the
conversion box. The other end of the cable connected to the customer device does not
have any connector, and the customers must prepare the connector themselves. In this
application, the maximum transmission distance is shorter than 200 m.
List of E1 trunk cables with SMB connectors
No.

BOM Number

Description

Quantity

Unit

04026814

Single Cable,120ohm,75ohm Converter Box(With


SMB Socket 14040127),PCB03022834+Box Body
21210634)

pcs

04022627

Trunk
2
Cable,10.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ751.2/0.25,HONET,W2524

pcs

04022629

Trunk
2
Cable,20.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ751.2/0.25,HONET,DL2526

pcs

04060205

Trunk
2
Cable,30.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ751.2/0.25,Wireless Intelligent Network

pcs

04023971

Trunk
2
Cable,40.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ751.2/0.25,C&C08B,DL3133

pcs

04023972

Trunk
2
Cable,50.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ751.2/0.25,C&C08B,DL3134

pcs

04043079

Trunk
2
Cable,65.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ751.2/0.25

pcs

No.

BOM Number

Description

Quantity

Unit

04042130

Trunk
2
Cable,70m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2
/0.25

pcs

04042131

Trunk
2
Cable,80m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2
/0.25

pcs

10

04042132

Trunk
2
Cable,90m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2
/0.25

pcs

11

04043080

Trunk
Cable,100.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ7
5-1.2/0.25

pcs

12

04060171

Trunk Cable,155M
Self-Loop,5m,75ohm,4.0mm,SMB75SF-IV,SYV75-2/
0.34(S),SMB75SF-IV,OptiX

pcs

Configuration Notes of the E3/T3 Interface Cable


List of E3 trunk cables with SMB connectors

No.

BOM Number

Description

Quantity

Unit

04060171

Trunk Cable,155M
2
Self-Loop,5m,75ohm,4.0mm,SMB75SF-IV,SYV75-2/0.34(
S),SMB75SF-IV,OptiX

pcs

04044335

Trunk
2
Cable,155M/Clock/Lightning,10m,75ohm,3.9mm,SMB75S
F-IV,SYV75-2/0.34(S)

pcs

04044336

Trunk
2
Cable,155M/Clock/Lightning,20m,75ohm,3.9mm,SMB75S
F-IV,SYV75-2/0.34(S)

pcs

04044337

Trunk
2
Cable,155M/Clock/Lightning,30m,75ohm,3.9mm,SMB75S
F-IV,SYV75-2/0.34(S)

pcs

8 External Optical Fiber Suites


List of commonly used optical fibers in the optical fiber suite (04100069)
No.

BOM Number

Description

14130296

Patch Cord,LC/PC-LC/PC,Multimode,A1b,2mm,5m

14130222

Patch Cord,LC/PC-LC/PC,Multimode,2mm,10m

14130295

Patch Cord,LC/PC-LC/PC,Multimode,2mm,20m

14130195

Patch Cord,LC/PC-LC/PC,Singlemode,2mm,5m

Quantity
The type and the
number of fibers
depend on the site
survey result.

Unit
pcs
pcs
pcs
pcs

14130199

Patch Cord,LC/PC-LC/PC,Singlemode,2mm,10m

pcs

14130251

Patch Cord,LC/PC-LC/PC,Singlemode,2mm,20m

pcs

14130248

Adapter,LC/PC-LC/PC,2,Blue,Shell:Plastic,Sleeve:Zirco
nia,Square

pcs

14130197

Patch Cord,FC/PC,LC/PC,Singlemode,2mm,10m

pcs

14130221

Patch Cord,FC/PC,LC/PC,Multimode,2mm,10m

pcs

10

14130196

Patch Cord,LC/PC-SC/PC,Singlemode,2mm,10m

pcs

11

14130223

Patch Cord,LC/PC-SC/PC,Multimode,2mm,10m

pcs

12

14130375

Patch Card,MPO-MPO,Multimode,0.3m,8 Cores Ribbon


Fiber

pcs

13

14130335

Optic Fiber
Connector,LC/PC,LC/PC,Multi-mode,2mm,1m

pcs

9 Accessories
List and configuration description of accessories of the NE40E-X16
No.
0

Code
21100144

Description
Nonmetal Parts,DKBA0.480.0457-GT-300I- Wire
Clip-300*3.6mm-Strength 18.2kg

Configuration Notes
Each NE40E-X16 is configured
with 200 pcs.
It is not required on the NE80E.

21100015

Nonmetal Parts,DKBA0.480.0457-GT 150I,Wire


Strip,150*3.6mm,Strength 18.2kg

It is mandatory. Each
NE80E/NE40E-X16 is configured
with 100 pcs.

21100041

Nonmetal Parts,DKBA0.480.0457-GT 100M,Wire


Strip,100*2.5mm,Strength 8.1kg

It is mandatory. Each
NE80E/NE40E-X16 is configured
with 100 pcs.

28010026

Insulation Material,Fireproof PVC Corrugated Tube,D2 It is optional and is provided for


the NE40E/80E-16 to be delivered
only outside China. It is selected
based on the site survey result. By
default, a 30 m tube is provided.

14080082

Network Interface Connector,8Bit 8Pin,Crystal


Plug,Matching 25050014

It is provided based on the site


survey result. By default, it is not
provided.

25050014

Twisted-Pair Cable,100ohm,Category 5e
UTP,0.51mm,24AWG,8Cores,PANTONE 430U,Used
with Plug:14080082

It is provided based on the site


survey result. By default, it is not
provided.

29041060

Engineering/Blank label,Engineering label,Signal Cable It is mandatory. Each


label,30 Groups,10 Array,3 Row,Height 22.0,Width
NE80E/NE40E-X16 is configured
84.0,Matte White,1Pcs/Group
with 6 pcs.

29042491

DKBA4.150.0999MX,Cabinet
LOGO,Router,90mm*30mm,Plastic

It is mandatory when a cabinet is


delivered. Each
NE80E/NE40E-X16 is configured
with 2 pcs.

No.

Code

Description

Configuration Notes

02234474

NetEngine5000E,Engineering Required Delivery


Accessory Per Integrated Chassis

It is mandatory. Each
NE80E/NE40E-X16 is configured
with 1 pcs.

21500093

Q/DKBA4.127.0355MX,Side Hang FMTs,NGN Cabinet It is mandatory when a cabinet is


delivered. Each
NE80E/NE40E-X16 is configured
with 4 pcs.

10

26010552

Cross Recessed Pan Head Thread forming


Screws,M5*10,Zinc Electroplating, iridescent
yellow,GB6560-86

It is mandatory when a cabinet is


delivered. Each
NE80E/NE40E-X16 is configured
with 8 pcs. The NE80E with the
AC power supply are configured
with 16 pcs. The screws are used
to fix the slide rails of the AC
power distribution cabinet. Each
slide rail is configured with 4 pcs.
There are four slide rails;
therefore, the NE80E needs to be
configured with 16 pcs.

11

31185644

HUAWEI NetEngien40E Universal Service Router


Product Documentation-(V600R005C00_01)

It is quoted separately. Each


NE40E, NE40E-X3, NE40E-X8, or
NE40-X16 to be delivered outside
China is configured with 1 pcs.
This CD-ROM applies to only a
router running V600R005C00; for
a router running another version,
an appropriate CD-ROM is
required.

12

31185645

HUAWEI NetEngien40E Universal Service Router


Product Documentation-(V600R005C00_01)

It is quoted separately. Each


NE80E is configured with 1 pcs.
This CD-ROM applies to only a
router running V600R005C00; for
a router running another version,
an appropriate CD-ROM is
required.

13

31185648

HUAWEI NetEngien80E Core Router Product


Documentation-(V600R005C00_01)

It is quoted separately. Each


NE80E to be delivered in China is
configured with 1 pcs. This
CD-ROM applies to only a router
running V600R005C00; for a
router running another version, an
appropriate CD-ROM is required.

14

31185649

HUAWEI NetEngien80E Core Router Product


Documentation-(V600R005C00_01)

It is quoted separately. Each


NE80E to be delivered outside
China is configured with 1 pcs.
This CD-ROM applies to only a
router running V600R005C00; for
a router running another version,
an appropriate CD-ROM is
required.

15

02400376

Power Distribution
Cabinet,220V,50/60HZ,72000mA,None,EPS200-4850
A

It is quoted separately. It is
mandatory when an NE40E-X16
with the AC power supply is
delivered. Each NE40E-X16 is
configured with 2 pcs.

16

02130872

Power
It is quoted separately. It is
module--33degC-65degC-90VAC-290VAC-(-53.5)VDC mandatory when an
NE80E/NE40E-X16 with the AC

No.

Code

Description

Configuration Notes

/54.2A-AC/DC rectifier

power supply is delivered. Each


NE80E/NE40E-X16 is configured
with 8 pcs.

17

21240150

DKBA8.201.1797,Standard Guide Rail,N68E Cabinet

It is mandatory when an
NE40E-X16 with two AC power
supply cabinets is to be delivered.
Each NE40E-X16 is configured
with 4 pcs, with each AC power
supply cabinet configured with
with 2 pcs.

18

02120415

NetEngine5000E,CR5E3TSR,AC Distribution Frame


for Cabinet,2 or 6 Input,6(2*3) Output,6 Group of 2
Poles 20A Air Switch

It is quoted separately. It is
mandatory when an NE80E with
the AC power supply is delivered.
Each NE80E is configured with 1
pcs.

19

05116036

NetEngine40E&80E-4/8/16,
It is provided for the NE40E-8,
NetEngine40E&80E-4/8/16_C V600R005C00,Physical NE40E-4, or NE80E to be
Software Package,DVD China
delivered outside China. Each
NE40E-8, NE40E-4, or NE80E is
NetEngine40E&80E-4/8/16,
NetEngine40E&80E-4/8/16_O V600R005C00,Physical configured with 1 pcs. By default,
it is not provided.
Software Package,DVD Oversea

05116037

20

05116038
05116039

NetEngine40E-X8/X16,NetEngine40E-X8/X16_C
V600R005C00,Physical Software Package, DVD
China

It is mandatory. Each NE80E is


configured with 1 pcs.

NetEngine40E-X8/X16,NetEngine40E-X8/X16_O
V600R005C00,Physical Software Package, DVD
Oversea
21

28040011

Heat shrink tube/D11/Radial Shrinkage


Ratio>50%/Black

The insulated heat shrink tube is


selected according to 0.

22

28040009

Heat shrink tube,D14,Radial Shrinkage


Ratio>50%,Black

The insulated heat shrink tube is


selected according to 0.

23

28040013

Heat Shrink Tube/D18/Radial Shrink Rate>50%/Black

The insulated heat shrink tube is


selected according to 0.

25

02120641

Power Distribution Box,NE40E,DPD300-4-12,Dual-two It is configured based on the site


Inputs .Dual-six outputs ,High Power DC Distribution
survey result. When customers
Box,per output 80A
cannot provide 12 power channels
for the NE40E/80E-X16/-16, a
power distribution is required.
Customers need to purchase
power cables for the power
distribution box. Each Power
distribution box can support one
NE40E/80E-X16/-16.

26

21240446

DKBA61533919,X8 Mount_19inch,NE40E

21240447

DKBA61532828,X8 Mount_23inch,NE40E

It is mandatory for the NE40E-X8


(02354085) and
NE40E-X16(02354084) to be
delivered to the North America
market. An NE40E-X8 is
configured with 1 pcs and an
NE40E-X16 is configured with 2
pcs.

List and configuration description of NE40E-X3/NE40E-X8 accessories

No.

Code

Description

Configuration Notes

21100144

Nonmetal Parts,DKBA0.480.0457-GT-300I- Wire


Clip-300*3.6mm-Strength 18.2kg

Each NE40E-X8 is configured with


100 pcs. It is not required by other
devices.

21100015

Nonmetal Parts,DKBA0.480.0457-GT 150I,Wire


Strip,150*3.6mm,Strength 18.2kg

It is mandatory. Each NE40E-X8 is


configured with 100 pcs.

21100041

Nonmetal Parts,DKBA0.480.0457-GT 100M,Wire


Strip,100*2.5mm,Strength 8.1kg

It is mandatory. Each NE40E-X8 is


configured with 100 pcs.

14080082

Network Interface Connector,8Bit 8Pin,Crystal


Plug,Matching 25050014

It is provided based on the site


survey result. By default, it is not
provided.

25050014

Twisted-Pair Cable,100ohm,Category 5e
UTP,0.51mm,24AWG,8Cores,PANTONE 430U,Use
with Plug:14080082

It is provided based on the site


survey result. By default, it is not
provided.

28010026

Insulation Material,Fireproof PVC Corrugated


Tube,D25

It is optional and is provided for the


NE40E-X8 to be delivered only
outside China. It is selected based
on the site survey result. By default,
a 30 m tube is provided.

29041060

Engineering/Blank label,Engineering label,Signal


Cable label,30 Groups,10 Array,3 Row,Height
22.0,Width 84.0,Matte White,1Pcs/Group

It is mandatory. Each NE40E-X8 is


configured with 4 pcs.

29042491

DKBA4.150.0999MX,Cabinet
LOGO,Router,90mm*30mm,Plastic

It is mandatory when a cabinet is


delivered. Each NE40E-X8 is
configured with 2 pcs.

31185644

HUAWEI NetEngien40E Universal Service Router


Product Documentation-(V600R005C00_01)

It is quoted separately. Each


NE40E, NE40E-X3, NE40E-X8, or
NE40-X16 to be delivered inside
China is provided with 1 pcs. This
CD-ROM applies to only a router
running V600R005C00; for a router
running another version, an
appropriate CD-ROM is required.

31185645

HUAWEI NetEngien40E Universal Service Router


Product Documentation-(V600R005C00_01)

It is quoted separately. Each


NE40E, NE40E-X3, NE40E-X8, or
NE40-X16 to be delivered outside
China is provided with 1 pcs. This
CD-ROM applies to only a router
running V600R005C00; for a router
running another version, an
appropriate CD-ROM is required.

10

02234474

NetEngine5000E,Engineering Required Delivery


Accessory Per Integrated Chassis

It is mandatory. Each NE40E-X8 is


configured with 1 pcs.

11

21500093

Q/DKBA4.127.0355MX,Side Hang FMTs,NGN


Cabinet

It is mandatory when a cabinet is


delivered. Each NE40E-X8 is
configured with 2 pcs.

12

26010552

Cross Recessed Pan Head Thread forming


Screws,M5*10,Zinc Electroplating, iridescent
yellow,GB6560-86

It is mandatory when a cabinet is


delivered. Each NE40E-X8 with the
DC power supply is configured with
4 pcs.
Each NE40E-X8 with the AC power
supply is configured with 8 pcs.

13

02400376

Power Distribution
It is quoted separately. It is
Cabinet,220V,50/60HZ,72000mA,None,EPS200-485 mandatory on an NE40E-X8 with

No.

Code

Description
0A

Configuration Notes
the AC power supply. Each
NE40E-X8 is configured with 1 pcs.

14

02130872

Power
It is quoted separately. It is
module--33degC-65degC-90VAC-290VAC-(-53.5)VD mandatory on an NE40E-X8 with
C/54.2A-AC/DC rectifier
the AC power supply. Each
NE40E-X8 is configured with 4 pcs.
It is not provided for other cabinets.

15

21240150

DKBA8.201.1797,Standard Guide Rail,N68E Cabinet It is mandatory for an NE40E-X8


with the AC power supply. Each
NE40E-X8 is configured with 2 pcs
for installing the AC-input cabinet.

16

05116036

NetEngine40E&80E-4/8/16,
NetEngine40E&80E-4/8/16_C
V600R005C00,Physical Software Package,DVD
China

05116037

It is applicable to the NE40E-8/-4


and NE80E and sold based on
versions. By default, it is not
delivered with the router.

NetEngine40E&80E-4/8/16,
NetEngine40E&80E-4/8/16_O
V600R005C00,Physical Software Package,DVD
Oversea
05116038
05116039

NetEngine40E-X8/X16,NetEngine40E-X8/X16_C
V600R005C00,Physical Software Package, DVD
China
NetEngine40E-X8/X16,NetEngine40E-X8/X16_O
V600R005C00,Physical Software Package, DVD
Oversea

05116040
05116041

NetEngine40E-X3,NetEngine40E-X3_C
V600R005C00,Physical Software Package,DVD
China

It is applicable to the
NE40E-X8/-X16 and sold based on
versions. By default, it is not
delivered with the router.

It is applicable to the NE40-X3 and


sold based on versions. By default,
it is not delivered with the router.

NetEngine40E-X3,NetEngine40E-X3_O
V600R005C00,Physical Software Package,DVD
Oversea
19

21500182

DKBA4.150.0747MX,Mount Angle,NE20-4(3U)
Chassis of NGN

It is mandatory. Each 20 U
NE40E-8 (02351014) is configured
with 1 pcs.

20

21500200

DKBA4.150.0546MX,Mount Angle
Component,NE40E

It is mandatory. Each 22 U
NE40E-8 (02350762) is configured
with 1 pcs.

21

21240160

DKBA4.150.0923MX,Mount,NE40E-4

It is mandatory. Each NE40E-4 is


configured with 1 pcs.

22

28040011

Heat shrink tube/D11/Radial Shrinkage


Ratio>50%/Black

The insulated heat shrink tube is


selected according to 0.

23

28040009

Heat shrink tube,D14,Radial Shrinkage


Ratio>50%,Black

The insulated heat shrink tube is


selected according to 0.

24

28040013

Heat Shrink Tube/D18/Radial Shrink


Rate>50%/Black

The insulated heat shrink tube is


selected according to 0.

25

02120641

Power Distribution
Box,NE40E,DPD300-4-12,Dual-two Inputs .Dual-six
outputs ,High Power DC Distribution Box,per output
80A

It is configured based on the site


survey result. When customers
cannot provide six power channels
for the NE40E/80E-X8/-8, a power
distribution is required. Customers
need to purchase power cables for
the power distribution box. Each
power distribution box can support
a maximum of two

No.

Code

Description

Configuration Notes
NE40E/80E-X8/-8s.

26

27

28

21240442

DKBA61532830,X3(DC) Mount_19inch,NE40E

21240443

DKBA61532826,X3(DC) Mount_23inch,NE40E

21240444

DKBA61532831,X3(AC) Mount_19inch,NE40E

21240445

DKBA61532827,X3(AC)Mount_23inch,NE40E

21240446

DKBA61533919,X8 Mount_19inch,NE40E

21240447

DKBA61532828,X8 Mount_23inch,NE40E

It is designed exclusively and


mandatory for the NE40X3-DC
chassis (0235****) to be delivered
to the North America market.
It is designed exclusively and
mandatory for the NE40X3-DC
chassis (02354559) to be delivered
to the North America market.
It is designed exclusively and
mandatory for the NE40E-X8
(02354085) and
NE40E-X16(02354084) to be
delivered to the North America
market. An NE40E-X8 is configured
with 1 pcs and an NE40E-X16 is
configured with 2 pcs.

Insulated heat shrink tubes on different chassis/core diameters of power cables


Cable
Diameter

Code of an
Insulated
Heat Shrink
Tube

Length of an Insulated
Shrink Tube (cm)

Heat

NE40E-X16

NE40E-X8

NE40E-X3

16mm2

28040011

150

100

50

25mm2

28040009

150

100

50

35mm2

28040013

150

100

You might also like