Professional Documents
Culture Documents
BEAM CONNECTION
Project :
Rev. :
Building :
Date :
Engineer :
Reviewer :
DATA
Steel Shape
WF-350x175x7x11
Steel grade
A36
Height
Hl
(mm.)
350
Width
Bl
(mm.)
175
Web thickness
twl
(mm.)
Flange thickness
tfl
(mm.)
11
Corner radius
(mm.)
14
Fy (N/mm2)
2
Bearing strength Fu (N/mm )
Yield stregth
T(n)
T(n-1)
T2
T1
245
400
End Plate
Bolt-bolt distance
T4
T3
(nb-1)p
Bolts
100
Column number
p (mm.)
na (NOS)
Row number
nb (NOS)
Bolt type
Moment
(kN-m)
244.5
(kN)
65.0
207
308
Diameter of bolt D =
24
mm
Rs = Abolt.Fv =
94
kN (Shear)
100
mm
Rt = Abolt.Ft =
139
kN (Tension)
100
200
300
400
500
y2 (mm2)
10000
40000
90000
160000
250000
(nb - 1).p =
Inertia of Bolts :
Tension stress due to load :
Ay2 =
ft = My/Ay2 =
245.7
N/mm
fv = V/A =
12.0
N/mm2
500
mm
mm4
497628276
2
< Ft'
12
308
Row number
24
452
A325-X
Ok !!