PARAMETER PENELITIAN

1. PARAMETER TANAH
Top Layer (Lanau Berpasir/ML)

= 16,32 kN/m3

= 3,2

phi

= 39,08 0

kPa

Middle Layer (Pasir Berlanau/SM)

= 17,92 kN/m3

= 5,4

phi

= 29,35 0

kPa

Bottom Layer (Lanau Berpasir/ML)

= 17,12 kN/m3

= 110

kPa

phi

= 35

Korelasi c

Korelasi phi

Korelasi gamma b

2. PARAMETER NAIL
Bond Diameter

= 0.1 m

(diameter bor)

Bond SF

= 1.5

Bond Skin Friction

= 100 kPa

(tergantung jenis tanah)

Nail Spacing

=2m

(jarak horizontal)

Bar Capacity

= 300 kN

dari jenis baja yang dipakai,

(ultimate breaking capacity of the bar)


Bar SF

= 1.5

Shear Capacity

=0

Shear Safety

=1

Bar capacity and reinforcement load


SLOPE/W allows you to specify the ultimate breaking capacity of the bar together
with a bar safety factor and an anchor spacing. The maximum reinforcement load
for a tensioned anchor is computed as:
Maximum Reinforcement Load = Bar Capacity Bar Safety Factor Spacing
Bond resistance
The Bond Resistance is the design pullout resistance per unit length of the bonded
zone. The Bond Resistance is a computed value based on the borehole diameter,
the unit bond skin friction, a specified bond safety factor and the anchor spacing.
In equation form:
Bond Resistance = Unit bond Skin friction x p x Bond Diameter
The Bond Resistance is in units of force per unit length (F/L) of bond. The
maximum pullout resistance available is the Bond Resistance times the total
bonded length. In equation form:
Maximum Pullout Resistance = Bond Resistance Bond Safety Factor Spacing