Example 5.1.

Analyzing Ideal Pressure Buildup Testing


The Data Given :
Q
400 stb/d
o
1.25 rb/stb
h
20 ft

0.2
rw
0.29 ft
o
1.1 cp
ct
0.0000195 1/psi
((+
Shut-in time
t (hr) ))/
0
2
4
8
16
24
48
x1
x2

37
19
10
5.5
4
2.5
1
10

m
k
s
pi

Pws
(psig)
1150
1795
1823
1850
1876
1890
1910
1925.967
1823.97
101.997

43.84 mD
2.9996
1960

Ideal Pressure Buildup Graph

f(x) = - 11.3333333333x + 1937.3333333333


R = 0.9897260274

Pws (psi)

Pws
(psia)
1165
1801
1838
1865
1891
1905
1925

100

10
log (tp+t)/t

Data PBU :
time
pressure
10.32266 3605.13
10.32307 3625.13
10.3232 3649.64
10.324 3676.83
10.3245 3705.84
10.325 3717.57
10.328 3836.92
10.33 3911.79
10.334 4001.46
10.337 4068.22
10.341 4138.73
10.364 4379.53
10.381
10.396
10.415
10.439
10.453
10.469
10.487
10.507
10.53
10.555
10.584
10.616
10.652
10.692
10.737
10.788
10.839
10.891
10.934
10.994
11.046
11.51
12.026
13.007
14.039
15.02
18.013
19.046
20.026
21.007
22.039
23.02

24.001
25.033
26.013
27.046
28.026
29.007
30.039
31.02
32.001
33.033
34.013
34.322