B.

SEISMIC LOAD COMPUTATION


Location:
Soil Profile Type:

(more than 5km from fault line)


Stiff Soil Profile (Sd)

Numerical Coefficient:
For reinforced concrete moment resisting frame (Cf)
Cf=

0.0731

NSCP 6th Edition table 208.5.2.2

Na=

1.2

NSCP 6th Edition table 208 - 4

Nv=

1.6

NSCP 6th Edition table 208 - 5

Near Source Factor

Seismic Response Coefficient


Cq=
Cv=

0.44 Na
0.64 Nv

NSCP 6th Edition table 208 - 7


NSCP 6th Edition table 208 - 8

Seismic Importance Factor


I=

Z=

0.4

Miscelleneous Structure

Seismic Zone Factor


Zone 4

Numerical Coefficient (Special Moment Resisting Frame)


R=

8.5

NSCP 6th Edition table 208 - 11

Total Seismic Dead Load, WT


WT= W5 + W4 + W3 + W2 + W1
WT= 17212.1281+19060.3320+19765.6395+19765.6395+23024.4584
WT=

98828.2 KN

TATION

dition table 208.5.2.2

Fundamental Time Vibration, T


HN
=
13.300 m
CT
=
0.0731
T
=
CT/(HN)3/4
T
=
0.509 second
Since T<0.700 second
FT
=
0
Seismic Response Coefficient
CA

0.44NA

CA

Edition table 208 - 4

CV

0.528
0.64NV

Edition table 208 - 5

CV

1.024

P 6th Edition table 208 - 7


P 6th Edition table 208 - 8

Seismic Importance Factor


I=

Seismic Zone Factor


Z=

0.4

eneous Structure

P 6th Edition table 208 - 11

6395+23024.4584

Numerical Coefficient (Special Moment Resisting Frame)


R=

8.5

Total Design Base Shear, VSTATIC


1. VSTATIC

(CV)(I)(WT)/(R)(T)

VSTATIC

2. VSTATIC

23385.993 KN
2.5(CA)(I)(WT)/R

VSTATIC

3. VSTATIC

VSTATIC

4. VSTATIC

VSTATIC

15347.438 KN (Governs effective design ba


0.11(CA)(I)(WT)
15347.438 KN
0.8(Z)(NV)(I)(WT)/R
5952.946 KN

sisting Frame)

23385.993 15347.438

Governs effective design base shear)


15347.438
5952.9457