Project : PROPOSED GASOLINE STATION w/ COMMERCIAL BUILDING Design by :

LOGO Owner :

Location :
WILLIE ONG
SUMACAB NORTE , CABANATUAN CITY N.E.
Mark :

Location :
C-PEDESTAL
F-GF
Check by : Engr. Mark Christian D. Esguerra Date : 2/3/2022
500 mm
Material Properties Reinforcement Details: Summary:
Concrete f'c = 20.70 Mpa Location No. Location Size
Reinforcing fy = 476.00 Mpa Along x 4.00 Corner Rebar 16.00
Dimension is 500mm x 500mm of
Es = 200000 Mpa Along y 4.00 Side Rebar 16.00
columns with 12pcs - Ø16mm

500 mm
εcu = 0.0030 Cover (mm) 40.00
r = As/(b*h) 0.97%
Section Properties: Result:
Width = 500.00 mm Stirrup fy (Mpa) 276.00 Spacing Tie(mm) 120.00
Column Design is Safe
Height = 500.00 mm Stirrup bar(mm) 12.00 Confinement(mm) 75.00
Length = 2,000.00 mm
Applied forces: Shear Design Summary:
Load Case Pu Mx My Shear x Shear y Pu/Puallow Biaxial Shear resistance Spacing Shear resistance Spacing Remark
Remark
D/C D/C Ratio
kN kN/m kN/m kN kN Capacity(kN) Ratio Req. Capacity(kN) Ratio Req.
Case 1 = 385.26 4.61 6.59 2.71 15.07 Pass 0.135 0.040 49.79 0.20 100mm 53.92 0.09 120.00
Case 2 = 384.56 25.53 1.18 2.71 15.07 Pass 0.134 0.096 59.79 0.17 100mm 63.92 0.02 120.00
Case 3 = Pass - -
Case 4 = Pass - -
Case 5 = Pass - -
3D Interaction Diagram Along x Along y

Z-Axis
Interaction Diagram(Along x) Interaction Diagram(Along y)
5,000 φPn, kN
5,000
φPn, kN

4,000 4,000

3,000 3,000

2,000 2,000
Y-Axis

1,000 1,000
X-Axis
φMn, kNm
φMn, kNm
0 0
-600 -400 -200 0 200 400 600 -600 -400 -200 0 200 400 600

-1,000 -1,000

3D X-Axis Y-Axis Z-Axis -2,000 -2,000

Detailed Calculations
Shear Calculation Along X Along Y
Along X c Mn Pn φ φMn φPn c Mn Pn φ φMn φPn
● Minimum Shear Reinforcement NSCP 2015 410.6.2 0 0.0 4403.8 0.65 0.0 2862.5 0 0.0 4403.8 0.65 0.0 2862.5
Vu > 0.5φVc No shear reinforcement Required 410.6.2.1 635 52.7 4403.8 0.65 34.2 2862.5 635 52.7 4403.8 0.65 34.2 2862.5
Shear reinforcement required, 65.63 410.6.2.2 571 92.1 4403.8 0.65 59.9 2862.5 571 92.1 4403.8 0.65 59.9 2862.5
● Shear strength provided by concrete NSCP 2015 422.5.6 506 203.5 4403.8 0.65 132.3 2862.5 506 203.5 4403.8 0.65 132.3 2862.5
Vc (kN)= 115.78 442 287.0 3858.4 0.65 186.6 2508.0 442 287.0 3858.4 0.65 186.6 2508.0
● Shear strength provided by transverse reinforcement 377 352.8 3240.2 0.65 229.3 2106.2 377 352.8 3240.2 0.65 229.3 2106.2
Vs(kN) = 0 313 398.1 2585.0 0.65 258.7 1680.3 313 398.1 2585.0 0.65 258.7 1680.3
● Total Shear Strength 249 428.6 1838.8 0.69 294.4 1263.3 249 428.6 1838.8 0.69 294.4 1263.3
Vtotal (kN)= 86.84 184 394.3 1155.5 0.85 334.0 978.7 184 394.3 1155.5 0.85 334.0 978.7
● Maximum spacing of shear reinforcement (Table 410.7.6.5.2) 120 315.9 472.5 0.90 284.3 425.2 120 315.9 472.5 0.90 284.3 425.2
Spacing (mm)= 219.00 NSCP 2015 410.7.6.5.2 0 0.0 -1148.5 0.90 0.0 -1033.6 0 0.0 -1148.5 0.90 0.0 -1033.6
Along Y Code Requirements
● Minimum Shear Reinforcement NSCP 2015 410.6.2 NSCP 2015 Discription Req. Status
Vu > 0.5φVc No shear reinforcement Required 410.6.2.1 Min Width 250.0 CC
418.7.2.1
Shear reinforcement required, 93.75 410.6.2.2 Ratio 0.4 CC
● Shear strength provided by concrete NSCP 2015 422.5.6 418.7.4.1 Main Bar Ratio 1%-6% NC
Vc (kN)= 108.76 Req. Ties Along X 350.0
CC
● Shear strength provided by transverse reinforcement Actual Ties Along X 200.0
418.7.5.2
Vs(kN) = 0 Ties Along Y 350.0
CC
● Total Shear Strength Actual Ties Along Y 125.0
Vtotal (kN)= 81.57 Req. Spacing inside Lo 96.0
418.7.2.3 CC
● Maximum spacing of shear reinforcement (Table 410.7.6.5.2) Actual Spacing inside Lo 75.0 Legend CC = NSCP 2015 Code Compliant
Spacing (mm) = 144.00 NSCP 2015 410.7.6.5.2 Req. Spacing beyond Lo 96.0 NC = NSCP 2015 Non Code Compliant
418.7.2.5 NC
Actual Spacing beyond Lo 100.0

This spreadsheets is licensed only to Engr. Mark Christian D. Esguerra

You might also like