Inspection Report
Sample Client
Property Address:
Sample Street
Sample Report VA
Isaac Kieffer
39 Benton Court
Sterling, VA 20165
IsaacKieffer@gmail.com
(301) 204-2825
Table of Contents
Cover Page
Table of Contents
Intro Page
1 STRUCTURE
2 EXTERIOR
3 PLUMBING
4(A) ELECTRIC - GARAGE/EXTERIOR
4(B) ELECTRIC - UTILITY ROOM/INTERIOR
5(A) HVAC - UPPER LEVEL
5(B) HVAC - BASEMENT
6 INTERIOR
7(A) KITCHEN - BASEMENT
7(B) KITCHEN - MAIN LEVEL
Minor Discovery Summary
MAJOR Discovery Summary
General Summary
Enlighten Home Inspections, LLC is pleased to provide you with this home inspection report. This report is intended to
provide you with an evaluation of the general condition of the home on the date of the inspection. Please read the entire
report. The areas of the home that were inspected include: Structure, Exterior, Plumbing, Electric, HVAC (Heating,
Ventilation and Air Conditioning), Interior and Kitchen. For condominiums and cooperatives, common areas are NOT
inspected and are not part of a standard report. The structure and exterior are considered common areas in condominiums
and cooperatives.
The focus of the inspection was on major problems or concerns. A major problem or concern is a component that is
significantly deficient and would potentially cost $500.00 to repair or replace, or posses a threat to life or health. These
items, if any, are contained in this report and can be easily identified by locating an "X" in the "MA" (Major) column in each
section of this report. Look for the description of the problem or concern in the corresponding explanation below the
columns. Major problems or concerns can also be accessed by looking directly at the "MAJOR" Summary in this report.
During the course of identifying major problems or concerns, it is nearly inevitable that minor problems or concerns will be
located. A minor problem or concern is a component that is deficient and would more than likely cost less than $500.00 to
repair or replace. Minor problems or concerns can be easily identified by locating an "X" in the "m" (minor) column in each
section of this report. Look for the description of the problem or concern in the corresponding explanation below the
columns. Minor problems or concerns can also be accessed by looking directly at the "MINOR SUMMARY" in this report. It
is important to note that this inspection is not an all inclusive inspection and not every minor defect is noted in this report.
It is my sincere hope that you find this report and our services to be beneficial. Thank you for choosing Enlighten Home
Inspections, LLC for your home inspection needs.
Regards,
Isaac Kieffer
Occupied:
No
1. STRUCTURE
Styles & Materials
STRUCTURE ACCESS: FOUNDATION TYPE: FOUNDATION MATERIALS:
LIMITED BY: Finished basement Original construction Concrete block/CMU (concrete masonry
VIEWED FROM: Exterior Basement unit)
FOUNDATIONAL SETTLEMENT: STRUCTURE TYPE: FRAMING SETTLEMENT:
DEGREE: Moderate Original construction DEGREE: Slight
Solid masonry
MOISTURE CONTROL(S): OTHER FACTORS:
Driveway drain COMPLETE PEST INFESTATION/WOOD
Outside storm drain(s) BORER INSPECTION RECOMMENDED
Window well(s) PROBABILITY OF PAST
DAMPNESS/SEEPAGE OR FLOODING:
High
PROBABILITY OF FUTURE
DAMPNESS/SEEPAGE OR FLOODING:
High - improvements needed
Uneven floors
Unable to determine if water intrusion will
occur due to lack of heavy rain
IN NI MA m RR FYI
1.0 FOUNDATION WALLS • •
1.1 FLOOR SLAB •
1.2 SEEPAGE/DAMPNESS •
1.3 FRAMING •
1.4 MASONRY WALLS •
1.5 STRUCTURAL STEEL • •
1.6 CHIMNEY •
1.7 FOR YOUR INFORMATION •
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
1.0 Foundation settlement crack(s): Garage (Picture 1) - recommend contacting a licensed structural engineer to
further evaluate
1.5 Rusted lintels: Multiple windows/doors (Pictures 1, 2) - keep lintels scraped and painted to prevent expansion
from rusting
2. EXTERIOR
Recommended that a licensed general contractor perform all repairs noted in this section.
IN NI MA m RR FYI
2.0 ROOF COVERING • •
2.1 ROOF DRAINAGE • •
2.2 ROOF FLASHING •
2.3 SIDING • •
2.4 TRIM •
2.5 MASONRY • •
2.6 CHIMNEY(S) • •
2.7 EXTERIOR DOOR(S) • •
2.8 SAFETY RAILS • •
2.9 STEPS/STAIRS •
2.10 DRIVEWAY •
2.11 GARAGE DOOR(S) •
2.12 WALKWAY(S) •
2.13 PATIO •
2.14 LANDSCAPING • •
2.15 EXTERIOR DRAINAGE • •
2.16 DRIVEWAY DRAIN • •
2.17 RETAINING WALL(S) • •
2.18 WINDOW WELL(S) •
2.19 FENCE(S) •
2.20 FOR YOUR INFORMATION •
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
2.0 MONETARY CONCERN: Damaged/missing/aged slate: Main roof back side (Pictures 1-5) - consult a licensed
roofing contractor
2.1 Improper drainage/damaged underground drain: Downspouts (Picture 1) - recommend extending downspouts a
minimum of 8-10 feet away from the foundation walls, further if possible. Use smooth wall pipe for extensions
2.3 Seal siding at penetration points: Multiple areas (Pictures 1, 2) - recommend sealing all siding penetrations with
duct seal
2.6 (1) Missing flue cap and screen: Left chimney (Picture 1), Rear patio fireplace (Picture 2)
2.7 SAFETY CONCERN: Double cylinder deadbolt: Basement (Picture 1), Front door (Picture 2) - recommend
replacing with a deadbolt that is operable from the interior without a key
2.8 (1) SAFETY CONCERN - Missing hand rail: Front left stairs (Picture 1), Right side (Picture 2), Backyard
(Picture 3) - handrails should be continuous along the entire length of the stairs
2.8 (2) SAFETY CONCERN - Loose hand/safety rail: Left side stairs (Picture 4)
2.14 MONETARY CONCERN - Large tree(s) overhanging: Multiple trees (Picture 1) - keep branches trimmed away
from roof and house
2.15 Ponding/wet areas: Front (Picture 1) - maintain a positive flow of surface water away from foundation walls
2.17 SAFETY CONCERN - Retaining walls bowed/pulling away from the house: Back left side (Pictures 1, 2) -
monitor
2.20 For your information: Clean debris from window well(s) to allow water to drain quickly (Picture 1)
3. PLUMBING
Recommended that a licensed plumber perform plumbing repairs noted in this section.
IN NI MA m RR FYI
3.0 WATER HEATER •
3.1 TOILET(S) •
3.2 DRAIN(S) • •
3.3 FAUCET(S) • •
3.4 VALVE(S) • •
3.5 DRAIN POP-UP • •
3.6 FIXTURES •
3.7 BATHROOM TILE/WALL PROTECTION • •
3.8 SHOWER DOOR/SURROUND •
3.9 PIPES AND FITTINGS •
3.10 DRAIN/WASTE/VENT PIPES (DWV) •
3.11 BATH VENT(S) •
3.12 HOSE BIBB(S) • •
3.13 LOW WATER FLOW •
3.14 GAS METER •
3.15 GAS PIPE • •
3.16 FOR YOUR INFORMATION •
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
3.2 (1) S trap: Basement bar sink (Picture 1), Upper level bathroom sink (Picture 2) - these traps tend to easily
siphon dry even when well-vented
3.2 (3) Clogged/slow drain: Jack and Jill bathroom bathtub (Picture 4), Upper level bathroom sink (Picture 5),
Upper level bathroom bathtub (Picture 6)
3.3 Faucet leaks: Jack and Jill bathroom shower head (Picture 1), Upper level bathroom shower head (Picture 2)
3.4 (1) Corroded valve(s): Utility room washer cold water line (Picture 1), Main level kitchen sink ice maker shut-off
(Picture 2)
3.4 (2) Valves leak: Basement bathroom shower (Picture 3), Entryway bathroom sink cold water handle (Picture 4),
Jack and Jill bathroom toilet (Picture 5)
3.4 (3) Hot and cold handles reversed: Basement bar sink (Picture 6)
3.7 (1) Missing/cracked caulk: Bathtub(s)/shower(s) at the tile and floor (Picture 1)
3.7 (3) Cracked grout: Jack and Jill bathroom bathtub tiles (Picture 4)
3.9 For your information: Freeze vulnerable pipes - Rear hose bibb (Picture 1)
3.12 Vacuum breaker(s) missing - All hose bibbs (Picture 1) - can compromise public water supply safety
3.15 SAFETY CONCERN - Missing a gas shut-off valve outside of the fireplace: Rear patio (Picture 1), Basement
(Picture 2)
3.16 (1) For your information: Recommend installing a washer pan with a drain
3.16 (2) For your information: Recommend installing No Burst or Flood Chek washer hoses
3.16 (3) For your information: Recommend installing a solid aluminum dryer vent instead of the foil vent (Picture 1)
IN NI MA m RR FYI
4.0.A ELECTRIC PANEL • •
4.1.A SUB PANEL •
4.2.A CIRCUIT BREAKERS • •
4.3.A CIRCUITS/CABLES • •
4.4.A SERVICE ENTRY CABLE (SEC) •
4.5.A METER/METER BASE •
4.6.A GROUND •
4.7.A RECEPTACLES • •
4.8.A INSTALLATION/OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTER(S) • •
4.9.A SWITCHES/DIMMERS •
4.10.A JUNCTION/WORK BOXES • •
4.11.A LIGHT FIXTURES • •
4.12.A CEILING FAN(S) • •
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
4.0.A Improper cover screws: Electric panel (Picture 1) - pointed screws should never be used to secure the panel
cover
4.3.A (2) Unprotected connections: Backyard (Picture 2) - all connections should be made in a covered junction
box
4.3.A (3) Improper connections: Electric panel buss neutrals (Picture 1) - there should be no more than one neutral
per lug.
4.8.A SAFETY CONCERN - Missing GFCI receptacle(s): Multiple exterior receptacles (Pictures 1-6)
4.10.A Missing cover plate(s): Garage junction box (Picture 1), Front door (Picture 2)
4.11.A Missing/burned bulb(s): Rear patio ceiling fan (Picture 1), Garage (Picture 2), Front door (Picture 3), Left
side (Picture 4)
IN NI MA m RR FYI
4.0.B ELECTRIC PANEL •
4.1.B SUB PANEL • •
4.2.B CIRCUIT BREAKERS • •
4.3.B CIRCUITS/CABLES • •
4.4.B SERVICE ENTRY CABLE (SEC) •
4.5.B METER/METER BASE •
4.6.B GROUND •
4.7.B RECEPTACLES • •
4.8.B INSTALLATION/OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTER(S) • •
4.9.B SWITCHES/DIMMERS • •
4.10.B JUNCTION/WORK BOXES •
4.11.B LIGHT FIXTURES • •
4.12.B CEILING FAN(S) • •
4.13.B BATH FAN(S) •
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
4.1.B (1) Improperly terminated cables: Utility room sub panel (Picture 1)
4.1.B (2) Loose panel cover: Utility room sub panel (Picture 2)
4.3.B Missing wire clamp: Basement kitchen sink disposer feed wire (Picture 1)
4.7.B (1) Wall plate(s) missing: Basement bathroom (Picture 1). Main level middle bedroom closet (Pictures 2, 3),
Master bedroom (Picture 4)
4.7.B (2) Reversed polarity: Basement bathroom (Picture 5), Basement rear right room (Picture 6), Main level
kitchen (Picture 7), Main level office (Picture 8), Main level hall (Picture 9), Attic front bedroom (Picture 10)
4.7.B (3) Ungrounded electrical receptacles: Basement rear right room (Pictures 11, 12)
4.8.B SAFETY CONCERN - Missing GFCI receptacle(s): Utility sink (Picture 1), Basement kitchen (Picture 2),
Basement bathroom (Picture 3), Basement bar (Pictures 4, 5), Main level kitchen (Picture 6), Entryway bathroom
(Picture 7), Upper level bathroom (Picture 8)
4.11.B (1) Unprotected closet fixture(s): Multiple closets (Picture 1) - recommend installing a fixture with a
protective globe
4.11.B (2) Missing/burned bulb(s): Main level middle bedroom closet (Picture 2), Main level hall ceiling fixtures
(Picture 3)
4.12.B Inadequate clearance: Basement rear right room ceiling fan (Picture 1) - blades should be a minimum of 7'
from the ground
IN NI MA m RR FYI
5.0.A AIR HANDLER •
5.1.A AIR CONDITIONER •
5.2.A FILTER •
5.3.A THERMOSTAT(S) •
5.4.A AUTOMATIC SAFETY CONTROLS •
5.5.A CONDENSATE DRAIN LINE(S) • •
5.6.A EMERGENCY DRAIN PAN •
5.7.A DUCTWORK/PLENUM •
5.8.A HEAT/COOL DISTRIBUTION •
5.9.A AIR REGISTERS •
5.10.A FOR YOUR INFORMATION •
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
5.5.A Missing cap: Attic AC condensate drain line (Picture 1)
5.10.A For your information: Recommend contacting a licensed AC technician to service the unit once a year in the
spring
IN NI MA m RR FYI
5.0.B COMBUSTION AIR • •
5.1.B FLUE/COMBUSTION GAS VENT • •
5.2.B AIR HANDLER •
5.3.B AIR CONDITIONER •
5.4.B FILTER • •
5.5.B THERMOSTAT(S) •
5.6.B AUTOMATIC SAFETY CONTROLS •
5.7.B CONDENSATE PUMP •
5.8.B CONDENSATE DRAIN LINE(S) • •
5.9.B DUCTWORK/PLENUM • •
5.10.B AIR REGISTERS •
5.11.B REFRIGERANT LINES •
5.12.B BOILER •
5.13.B VALVE(S) •
5.14.B BOILER PIPING •
5.15.B PRESSURE RELIEF VALVE •
5.16.B RADIATORS •
5.17.B FOR YOUR INFORMATION •
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
5.0.B Inadequate combustion air: Utility room (Picture 1) - recommend adding a louvered door
5.1.B HEALTH CONCERN - Seal furnace and water heater flues at the thimble to prevent carbon monoxide from
seeping into the house: Utility room (Pictures 1, 2)
5.4.B Dirty reusable HVAC filter: Utility room in the AC return plenum (Picture 1) - clean
5.17.B (1) For your information: Recommend contacting a licensed HVAC technician to service the heating and
A/C units twice a year
5.17.B (2) For your information: Recommend cleaning the reusable HVAC filter every 30 days of operational use
6. INTERIOR
Recommended that a licensed general contractor perform all repairs noted in this section.
IN NI MA m RR FYI
6.0 CEILINGS •
6.1 WALLS •
6.2 FLOORS •
6.3 TRIM •
6.4 DOORS (REPRESENTATIVE NUMBER) • •
6.5 WINDOWS (REPRESENTATIVE NUMBER) •
6.6 FIREPLACE(S) •
6.7 ATTIC INSULATION •
6.8 ATTIC VENTILATION •
6.9 ATTIC MOISTURE • •
6.10 STEPS, STAIRWAYS, BALCONIES AND RAILINGS • •
6.11 SMOKE DETECTORS • •
6.12 COUNTERS, CABINETS AND SHELVES •
6.13 FIRE SEPARATION • •
6.14 LEAD PAINT •
6.15 FOR YOUR INFORMATION •
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
6.4 Doors do not latch/doors rub/bind: Multiple doors (Pictures 1-3) - adjust hardware
6.10 (1) SAFETY CONCERN - Missing hand rail: Entryway stairs (Picture 1) - handrails should be continuous
along the entire length of the stairs
6.10 (2) SAFETY CONCERN - Safety rails do not meet current child safety standards: Upper level stairs (Picture 2)
- balusters should be spaced a maximum of 4" apart
6.11 SAFETY CONCERN - Inoperative smoke detector(s): Main level hall ceiling (Picture 1) - highly recommend
one smoke alarm in the general living space on each level, and one in each bedroom. Any smoke alarm ten or more
years old needs to be replaced. If the age cannot be determined, it is best to replace the alarm(s)
6.14 For your information: Any structure built prior to 1978 likely contains lead based paint
6.15 (1) For your information: Recommend contacting a licensed chimney sweep to clean and inspect the flues
6.15 (2) For your information: Recommend installing at least one carbon monoxide detector on every level and
within ten feet of every bedroom
IN NI MA m RR FYI
7.0.A RANGE • • •
7.1.A DISPOSER • •
7.2.A SINK •
7.3.A COUNTERTOPS/CABINETS •
7.4.A DRAWERS/DOORS • •
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
7.0.A (1) Inoperative oven light: Range (Picture 1)
7.0.A (2) SAFETY CONCERN - Anti-tip bracket not installed: Range (Picture 2)
7.4.A Missing hardware: Basement kitchen cabinet doors and drawers (Picture 1)
IN NI MA m RR FYI
7.0.B RANGE •
7.1.B RECIRCULATING RANGE HOOD •
7.2.B REFRIGERATOR • •
7.3.B DISHWASHER • •
7.4.B DISPOSER •
7.5.B MICROWAVE •
7.6.B SINK •
7.7.B COUNTERTOPS/CABINETS •
7.8.B DRAWERS/DOORS •
IN NI MA m RR FYI
IN= Inspected - OK at inspection, NI= Not Inspected, MA= Major problem, m= Minor problem, RR= Repair or Replace, FYI= For Your Information
Comments:
7.2.B Inoperative: Main level kitchen refrigerator ice maker (Picture 1) and water dispenser (Picture 2) - water line
does not appear to be hooked up
7.3.B (1) Loose: Dishwasher (Picture 1) - recommend securing to the countertop or cabinet
7.3.B (2) Continues to cycle at the one minute point and does not automatically shut off: Dishwasher (Picture 2)
39 Benton Court
Sterling, VA 20165
IsaacKieffer@gmail.com
(301) 204-2825
Customer
Sample Client
Address
Sample Street
Sample Report VA
The following items or discoveries indicate that these system(s) or component(s) do not function as intended, adversely
affect the habitability of the dwelling, appear to warrant further investigation by a specialist, or require subsequent
observation. Generally, this summary includes items that constitute "minor" problems or concerns. A minor problem or
concern is an item or discovery that would cost less than $500.00 to repair or replace. This summary shall not contain
recommendations for routine upkeep of a system or component to keep it in proper functioning condition or
recommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entire
report. The complete report may include additional information of concern to the customer. It is recommended that the
customer read the complete report.
1. STRUCTURE
1.5 STRUCTURAL STEEL
Minor problem, Repair or Replace
Rusted lintels: Multiple windows/doors (Pictures 1, 2) - keep lintels scraped and painted to prevent expansion
from rusting
1. STRUCTURE
2. EXTERIOR
2.1 ROOF DRAINAGE
Minor problem, Repair or Replace
Improper drainage/damaged underground drain: Downspouts (Picture 1) - recommend extending downspouts a
minimum of 8-10 feet away from the foundation walls, further if possible. Use smooth wall pipe for extensions
2.1 Picture 1
2.3 SIDING
Minor problem, Repair or Replace
Seal siding at penetration points: Multiple areas (Pictures 1, 2) - recommend sealing all siding penetrations with
duct seal
2. EXTERIOR
2.5 MASONRY
Minor problem, Repair or Replace
Eroded/cracked/missing mortar: Multiple areas (Pictures 1-16) - point up
2. EXTERIOR
2. EXTERIOR
2.6 CHIMNEY(S)
Minor problem, Repair or Replace
(1) Missing flue cap and screen: Left chimney (Picture 1), Rear patio fireplace (Picture 2)
2. EXTERIOR
2.6 Picture 3
2.15 Picture 1
2. EXTERIOR
2.16 Picture 1
3. PLUMBING
3.2 DRAIN(S)
Minor problem, Repair or Replace
(1) S trap: Basement bar sink (Picture 1), Upper level bathroom sink (Picture 2) - these traps tend to easily siphon
dry even when well-vented
3. PLUMBING
3.2 Picture 3
(3) Clogged/slow drain: Jack and Jill bathroom bathtub (Picture 4), Upper level bathroom sink (Picture 5), Upper
level bathroom bathtub (Picture 6)
3.2 Picture 6
3.3 FAUCET(S)
Minor problem, Repair or Replace
3. PLUMBING
Faucet leaks: Jack and Jill bathroom shower head (Picture 1), Upper level bathroom shower head (Picture 2)
3.4 VALVE(S)
Minor problem, Repair or Replace
(1) Corroded valve(s): Utility room washer cold water line (Picture 1), Main level kitchen sink ice maker shut-off
(Picture 2)
(2) Valves leak: Basement bathroom shower (Picture 3), Entryway bathroom sink cold water handle (Picture 4),
Jack and Jill bathroom toilet (Picture 5)
3. PLUMBING
3.4 Picture 5
(3) Hot and cold handles reversed: Basement bar sink (Picture 6)
3.4 Picture 6
3. PLUMBING
3.5 Picture 1
3.7 Picture 1
3. PLUMBING
(3) Cracked grout: Jack and Jill bathroom bathtub tiles (Picture 4)
3.7 Picture 4
3.12 Picture 1
4.0.A Picture 1
4.3.A CIRCUITS/CABLES
Minor problem, Repair or Replace
(1) Missing conduit: Rear patio lighting cables (Picture 1)
4.3.A Picture 1
(2) Unprotected connections: Backyard (Picture 2) - all connections should be made in a covered junction box
4.3.A Picture 2
(3) Improper connections: Electric panel buss neutrals (Picture 1) - there should be no more than one neutral per
lug.
4.3.A Picture 3
4.7.A RECEPTACLES
Minor problem, Repair or Replace
Wall plate(s) missing: Garage (Picture 1)
4.7.A Picture 1
4.12.A Picture 1
4.1.B Picture 1
4.1.B Picture 2
4.3.B CIRCUITS/CABLES
Minor problem, Repair or Replace
Missing wire clamp: Basement kitchen sink disposer feed wire (Picture 1)
4.3.B Picture 1
4.7.B RECEPTACLES
Minor problem, Repair or Replace
(1) Wall plate(s) missing: Basement bathroom (Picture 1). Main level middle bedroom closet (Pictures 2, 3), Master
bedroom (Picture 4)
(2) Reversed polarity: Basement bathroom (Picture 5), Basement rear right room (Picture 6), Main level kitchen
(Picture 7), Main level office (Picture 8), Main level hall (Picture 9), Attic front bedroom (Picture 10)
(3) Ungrounded electrical receptacles: Basement rear right room (Pictures 11, 12)
4.7.B Picture 13
4.9.B SWITCHES/DIMMERS
Minor problem, Repair or Replace
(1) Wall plate(s) missing: Utility room (Picture 1)
4.9.B Picture 1
4.11.B Picture 1
(2) Missing/burned bulb(s): Main level middle bedroom closet (Picture 2), Main level hall ceiling fixtures (Picture
3)
4.12.B Picture 1
5.5.A Picture 1
5.0.B Picture 1
5.4.B FILTER
Minor problem, Repair or Replace
Dirty reusable HVAC filter: Utility room in the AC return plenum (Picture 1) - clean
5.4.B Picture 1
5.8.B Picture 1
5.9.B DUCTWORK/PLENUM
Minor problem, Repair or Replace
Missing duct insulation: Garage (Picture 1)
5.9.B Picture 1
6. INTERIOR
6.4 DOORS (REPRESENTATIVE NUMBER)
Minor problem, Repair or Replace
Doors do not latch/doors rub/bind: Multiple doors (Pictures 1-3) - adjust hardware
6. INTERIOR
6.4 Picture 3
6. INTERIOR
Minor problem, Repair or Replace
Missing fire stop: Garage ceiling (Pictures 1, 2)
7.0.A Picture 1
7.1.A DISPOSER
Minor problem, Repair or Replace
Seized: Basement kitchen sink disposer (Picture 1)
7.1.A Picture 1
7.4.A DRAWERS/DOORS
Minor problem, Repair or Replace
Missing hardware: Basement kitchen cabinet doors and drawers (Picture 1)
7.4.A Picture 1
7.3.B DISHWASHER
Minor problem, Repair or Replace
(1) Loose: Dishwasher (Picture 1) - recommend securing to the countertop or cabinet
7.3.B Picture 1
(2) Continues to cycle at the one minute point and does not automatically shut off: Dishwasher (Picture 2)
7.3.B Picture 2
39 Benton Court
Sterling, VA 20165
IsaacKieffer@gmail.com
(301) 204-2825
Customer
Sample Client
Address
Sample Street
Sample Report VA
The following items or discoveries indicate that these system(s) or component(s) do not function as intended, adversely
affect the habitability of the dwelling, appear to warrant further investigation by a specialist, or require subsequent
observation. This summary includes those items that constitute "MAJOR" problems or concerns. A major problem or
concern is any item or discovery that would cost more than $500.00 to repair or replace. This summary shall not contain
recommendations for routine upkeep of a system or component to keep it in proper functioning condition or
recommendations to upgrade or enhance the function, efficiency, or safety of the home. This Summary is not the entire
report. The complete report may include additional information of concern to the customer. It is recommended that the
customer read the complete report.
1. STRUCTURE
1.0 FOUNDATION WALLS
Major problem, Repair or Replace
Foundation settlement crack(s): Garage (Picture 1) - recommend contacting a licensed structural engineer to
further evaluate
1. STRUCTURE
1.0 Picture 1
2. EXTERIOR
2.0 ROOF COVERING
Major problem, Repair or Replace
MONETARY CONCERN: Damaged/missing/aged slate: Main roof back side (Pictures 1-5) - consult a licensed
roofing contractor
2. EXTERIOR
2.0 Picture 5
2. EXTERIOR
2.8 Picture 3
2. EXTERIOR
(2) SAFETY CONCERN - Loose hand/safety rail: Left side stairs (Picture 4)
2.8 Picture 4
2.14 LANDSCAPING
Major problem, Repair or Replace
MONETARY CONCERN - Large tree(s) overhanging: Multiple trees (Picture 1) - keep branches trimmed away
from roof and house
2.14 Picture 1
2. EXTERIOR
3. PLUMBING
3.15 GAS PIPE
Major problem, Repair or Replace
SAFETY CONCERN - Missing a gas shut-off valve outside of the fireplace: Rear patio (Picture 1), Basement
(Picture 2)
4.2.A Picture 1
4.2.B Picture 1
6. INTERIOR
6.10 STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Major problem, Repair or Replace
(1) SAFETY CONCERN - Missing hand rail: Entryway stairs (Picture 1) - handrails should be continuous along
the entire length of the stairs
6.10 Picture 1
(2) SAFETY CONCERN - Safety rails do not meet current child safety standards: Upper level stairs (Picture 2) -
balusters should be spaced a maximum of 4" apart
6. INTERIOR
6.10 Picture 2
6.11 Picture 1
7.0.A Picture 2
General Summary
39 Benton Court
Sterling, VA 20165
IsaacKieffer@gmail.com
(301) 204-2825
Customer
Sample Client
Address
Sample Street
Sample Report VA
1. STRUCTURE
1.7 FOR YOUR INFORMATION
For Your Information
For your information: Recommend installing a dehumidifier in the basement
2. EXTERIOR
2.20 FOR YOUR INFORMATION
For Your Information
For your information: Clean debris from window well(s) to allow water to drain quickly (Picture 1)
2.20 Picture 1
2. EXTERIOR
3. PLUMBING
3.9 PIPES AND FITTINGS
For Your Information
For your information: Freeze vulnerable pipes - Rear hose bibb (Picture 1)
3.9 Picture 1
3.16 Picture 1
6. INTERIOR
6.14 LEAD PAINT
For Your Information
For your information: Any structure built prior to 1978 likely contains lead based paint
6.15 FOR YOUR INFORMATION
For Your Information
(1) For your information: Recommend contacting a licensed chimney sweep to clean and inspect the flues
(2) For your information: Recommend installing at least one carbon monoxide detector on every level and within
ten feet of every bedroom