17-12 MEGANE F5R 740 SIRIUS 3H PROGRAM No.: E3 VDIAG No.: 04 DF061 PRESENT or STORED IGNITION COIL 1 - 4 CIRCUIT CO= Open circuit or short circuit to earth CC1 = Short circuit to 12 volts DEF = Stored fault NOTES Restriction on the application of the fault finding procedure in the Gener ic Note: If DF008 Petrol pump relay circuit is present or stored, treat it as a priority because it may be causing your fault to appear. If DF002 Throttle body potentiometer circuit is present or stored, treat it as a priority because it ma y be causing your fault to appear. DF062 PRESENT or STORED IGNITION COIL 2-3 CIRCUIT CO= Open circuit or short circuit to earth CC1 = Short circuit to 12 volts DEF = Stored fault NOTES Restriction on the application of the fault finding procedure in the Generic Note: If DF008 Petrol pump relay circ uit iis present or stored, treat it as a priority because it may be causing your fault to appear. If DF002 Throttle body potentiometer circuit is present or sto red, treat it as a priority because it may be causing your fault to appear. DF08 8 PRESENT EGR VALVE POSITION SENSOR CIRCUIT 1DEF = EGR valve locked mechanically 2DEF = Unidentified electrical fault NOTES Restriction on the application of th e fault finding procedure in the Generic Note: If DF009 Actuator relay control c ircuit is present or stored, treat it as a priority because it may be causing yo ur fault to appear. If DF034 EGR solenoid valve circuit is present or stored, tr eat it as a priority because it may be causing your fault to appear. If DF002 Th rottle body potentiometer circuit is present or stored, treat it as a priority b ecause it may be causing your fault to appear. JSIE304P1.1 17 INJECTION Diagnostics - Fault Interpretation 17-13 MEGANE F5R 740 SIRIUS 3H PROGRAM No.: E3 VDIAG No.: 04 DF089 PRESENT OR STORED FUEL PRESSURE REGULATION CO= Open circuit on the petrol pressure regulation valv e control CC0= Short circuit to earth on the petrol pressure regulation valve control CC1= Short circuit to + 12 volts on the petrol pressure regulation valve control DEF= Unidentified electrical fault 1DEF = Petrol pressure regulation fault 2DEF = Petrol circuit fault NOTES This fault finding strategy replaces the one in the Generic Note. If DF009 Actuator relay control circuit is present or memorised, treat it as a priority because it may be causing your fault to appear. If DF019 Supply is present or st ored, treat it as a priority because it may be causing your fault to appear. If DF002 Throttle body potentiometer circuit is present or stored, treat it as a pr iority because it may be causing your fault to appear. ForSAFETYandCLEANLINESS r easons, it isVITAL TO FOLLOW THE INSTRUCTIONS PROVIDED IN THE METHOD SECTIONfor this vehicle. CO CC0 CC1 NOTES None Check theconnection and condition of the petrol pressure regulation v alve connector. Change the connector if necessary. With the ignition on, check f or the presence of12 volts on the petrol pressure regulation valve. Repair the c onnection line to the actuator relays if necessary. Check theresistance of the p etrol pressure regulation valve. Replace the valve if necessary. Connect the bor nier in place of the computer and checkthe insulation, continuity and absence of interference resistanceon the line: Injectioncomputer 6 Petrol pressure regulat ion valve Repair if necessary. AFTER REPAIR Clear the fault memory. Follow the instructions to confirm repair. Deal with any other possible faults. JSIE304P1.1 17 INJECTION Diagnostics - Fault Interpretation 17-14 MEGANE F5R 740 SIRIUS 3H PROGRAM No.: E3 VDIAG No.: 04 CONTINUED 1 1DEF NOTES If DF019 Supply is present or stored, treat it as a prior ity because it may be causing your fault to appear. The fault is declared presen t after the engine has been running for two minutes at idling speed. Check theco nnection and condition of the petrol pressure sensor connector. Change the conne ctor if necessary. Connect the bornier in place of the computer and checkthe ins ulation, continuity and absence of interference resistanceon the line: Injection computer 48 Petrol pressure sensor Injectioncomputer 74 Petrol pressure sensor I njectioncomputer 75 Petrol pressure sensor Repair if necessary. AFTER REPAIR Cle ar the fault memory. Follow the instructions to confirm repair. Deal with any other possible faults. JSIE304P1.1 17 INJECTION Diagnostics - Fault Interpretation 17-15 MEGANE F5R 740 SIRIUS 3H PROGRAM No.: E3 VDIAG No.: 04 CONTINUED 2 2DEF NOTES Before any operations, carry out the DF019 2DEF Supply fa ult finding procedure in this Technical Note, because this may be causing your f ault to appear. If DF004 Coolant temperature sensor circuit is present or stored , treat it as a priority because it may be causing your fault to appear. Conditi ons for applying the fault finding procedure to the fault stored. The fault is d eclared present after the engine has been running at idle speed for 2 minutes. OR The fault is declared present after the engine has been running at varying speeds for 2 minutes. ForSAFETYandCLEANLINESS reasons, it isVITAL TO FOLLOW THE INSTRUCTIONS PROVIDED IN THE METHOD SECTIONfor this vehicle. Visuallycheck forleaks in the petrol circ uit. Repair if necessary. Checkthe condition of the petrol filter. If it has any impurities, change the filter and check the cleanliness of the tank. Check for the presence of12 volts on track 66 of the injection computer. Repair the connection between track 66 on the injection computer and the actuato r relays if necessary. Check themanual operation of the petrol pump (measure flow and pressure). Change the petrol pump if necessary. Check that the petrol pressure sensor is in good working condition:See the vehicle conformity check to obtain the value of the pe trol pressure with the ignition on (PR074). Replace the sensor if necessary. Wit h the engine running at idle speed, checkthe petrol pressure value (see vehicle conformity check). minimum < PR074= maximum or PR074 > maximum The high pressure regulator is defective. Change the pressure regulator. PR074 <minimum Activate the regulator control to check that the regulator is not seized. Change the pressure regulator. The high pressure pump is faulty. AFTER REPAIR Clear the fault memory. Follow the instructions to confirm repair. Deal with any other possible faults. JSIE304P1.1 17 INJECTION Diagnostics - Fault Interpretation 17-16 MEGANE F5R 740 SIRIUS 3H PROGRAM No.: E3 VDIAG No.: 04 DF090 PRESENT OR STORED CAMSHAFT SENSOR DEF = Unidentified electrical fault NOTES Restriction on the app lication of the fault finding procedure in the Generic Note: If DF009 Actuator r elay control circuit is present or stored, treat it as a priority because it may be causing your fault to appe