100
Parameter
Clothing (clo)
Air temp. (C)
Mean radiant temp. (C)
Activity (met)
Air speed (m/s)
Relative humidity (%)

Input
2.00
25.0
22.0
2.0
0.25
70.0

[0 to 2clo]
[10 to 30C]
[10 to 40C]
[0.8 to 4met]
[0 to 1m/s]
[30 to 70%]

80

Parameter
Operative temp. (C)
PMV
PPD

Number of iterations:

Results
23.8
1.7
61.8
1.7
6

PPD

60

-3
61.80
1.7
0.00

40

20

Modified by Hkan Nilsson


Department of Technology and Built Environment
Laboratory of Ventilation and Air Quality
University of Gvle

0
-3

-2.5

-2

-1.5

-1

-0.5

0
PMV

0.5

1.5

2.5

PMV
-3
-2.9
-2.8
-2.7
-2.6
-2.5
-2.4
-2.3
-2.2
-2.1
-2
-1.9
-1.8
-1.7
-1.6
-1.5
-1.4
-1.3
-1.2
-1.1
-1
-0.9
-0.8
-0.7
-0.6
-0.5
-0.4
-0.3
-0.2
-0.1
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7

PPD
99.12
98.58
97.81
96.73
95.29
93.43
91.10
88.26
84.91
81.07
76.76
72.05
67.02
61.75
56.35
50.90
45.51
40.27
35.25
30.51
26.12
22.10
18.49
15.31
12.55
10.23
8.33
6.87
5.83
5.21
5.00
5.21
5.83
6.87
8.33
10.23
12.55
15.31
18.49
22.10
26.12
30.51
35.25
40.27
45.51
50.90
56.35
61.75

-3

-2.5

-2

-1.5

-1

-0.5

0.5

1.5

1.8
1.9
2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3

67.02
72.05
76.76
81.07
84.91
88.26
91.10
93.43
95.29
96.73
97.81
98.58
99.12